fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551. 1. CSV import ran no driver-typed config gate. Its typed columns were always strictly parsed, but the free-form TagConfigJson column reached the database unread, so a CSV could author a tag the driver rejects — one that deploys green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the offending row in the staged review grid, and RawTreeService enforces the same gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the API and any future caller reach none of them, and this repo has no bUnit). A rejected import row is an ERROR — the batch inserts nothing and the row is named — never a skip. Note the brief's premise that manual entry rides ImportTagsAsync is wrong: RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why the gate had to land on all three write paths. 2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum checks, so every rejection cause not on the list was invisible. They are now ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the driver's own reader for the verdict, then explain the refusal, with a catch-all so "the parse rejects but Inspect said nothing" is unreachable. That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and the type-dependent guards, plus causes the issue did not name (absent region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they diagnose rather than return empty. Authoring half: ModbusTagConfigModel gains stringByteOrder; AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember; S7TagConfigModel captures whether the SOURCE blob declared dataType and asks S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule. 4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's class remarks and AdminOperationsActor's comment all claimed invalid enums are "silently defaulted by the lenient runtime" — false since R2-11 Phase C made the runtime reads strict. They describe rejections now.
This commit is contained in:
@@ -189,16 +189,34 @@ public static class AbCipTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns on a present-but-invalid <c>dataType</c> (silently
|
||||
/// defaulted by the lenient runtime) and on a structurally unparseable TagConfig. Empty when clean
|
||||
/// or not an equipment-tag object. Never throws.
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection — the mapper only copies it
|
||||
/// onto <see cref="AbCipTagDefinition.Name"/> and never validates it.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns for a blob <see cref="FromTagConfig"/> would
|
||||
/// <b>reject</b> — a structurally unparseable or non-object document, an absent / non-string /
|
||||
/// blank <c>tagPath</c>, a present-but-invalid <c>dataType</c> (the runtime enum read is STRICT
|
||||
/// since R2-11 Phase C, so a typo rejects the tag), or a malformed declared UDT member (see
|
||||
/// <see cref="DescribeInvalidMember(JsonElement)"/>). Such a tag is skipped by the driver and reads
|
||||
/// <c>BadNodeIdUnknown</c> forever. Empty when the mapper accepts the blob, when it is blank, or
|
||||
/// when it is not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The verdict comes from <see cref="FromTagConfig"/>, not from a mirror</b> (Gitea #551) — see
|
||||
/// <c>ModbusTagDefinitionFactory.Inspect</c>'s remarks for the full argument.
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -208,16 +226,129 @@ public static class AbCipTagDefinitionFactory
|
||||
warnings.Add("AbCip TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<AbCipDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
|
||||
DescribeRejection(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("AbCip TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
if (warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"AbCip TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Runs only after the mapper has already refused, so it can never invent strictness.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("tagPath", out var tagPathEl) || tagPathEl.ValueKind != JsonValueKind.String)
|
||||
{
|
||||
warnings.Add(
|
||||
"AbCip TagConfig has no string 'tagPath' — AbCip is a symbolic driver and addresses by "
|
||||
+ "Logix tag path, so the driver will skip this tag and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
else if (string.IsNullOrWhiteSpace(tagPathEl.GetString()))
|
||||
{
|
||||
warnings.Add("AbCip TagConfig has a blank 'tagPath' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (TagConfigJson.DescribeInvalidEnum<AbCipDataType>(root, "dataType") is { } w) warnings.Add(w);
|
||||
|
||||
if (DescribeInvalidMember(root) is { } memberWarning) warnings.Add(memberWarning);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// <b>The single authority on the declared-UDT-member rules</b>, consulted by <see cref="Inspect"/>
|
||||
/// and by the AdminUI's <c>AbCipTagConfigModel.Validate</c> alike. Describes the FIRST malformed
|
||||
/// entry of the optional <c>members</c> array — a non-object entry, one with no usable <c>name</c>,
|
||||
/// or one whose <c>dataType</c> is a present-but-invalid <see cref="AbCipDataType"/> — or
|
||||
/// <see langword="null"/> when every member reads.
|
||||
/// <para>
|
||||
/// The member rules are as strict as the top-level ones (<see cref="FromTagConfig"/> refuses the
|
||||
/// WHOLE tag for one bad member), but no authoring surface checked them: the typed editor emits
|
||||
/// only <c>tagPath</c>/<c>dataType</c>/<c>writable</c> and <c>members</c> rides the model's
|
||||
/// preserved key bag untouched, so a hand-authored / CSV / API blob with a typo'd member
|
||||
/// deployed clean and died at the driver — Gitea #551 item 3.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// A <c>members</c> value that is absent or not a JSON array draws nothing: the mapper reads it
|
||||
/// only when it is an array, and an array of zero usable members simply means "no member
|
||||
/// fan-out". Saying otherwise here would make the gate stricter than the reader.
|
||||
/// </para>
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <returns>The warning text, or <see langword="null"/> when the members read.</returns>
|
||||
public static string? DescribeInvalidMember(JsonElement root)
|
||||
{
|
||||
if (!root.TryGetProperty("members", out var membersEl) || membersEl.ValueKind != JsonValueKind.Array)
|
||||
return null;
|
||||
|
||||
var index = 0;
|
||||
foreach (var member in membersEl.EnumerateArray())
|
||||
{
|
||||
var label = $"members[{index}]";
|
||||
index++;
|
||||
|
||||
if (member.ValueKind != JsonValueKind.Object)
|
||||
{
|
||||
return $"AbCip {label} is not a JSON object — a declared UDT member needs a 'name' and may "
|
||||
+ "carry a 'dataType'; the WHOLE tag is rejected (BadNodeIdUnknown).";
|
||||
}
|
||||
|
||||
if (!member.TryGetProperty("name", out var nameEl)
|
||||
|| nameEl.ValueKind != JsonValueKind.String
|
||||
|| string.IsNullOrWhiteSpace(nameEl.GetString()))
|
||||
{
|
||||
return $"AbCip {label} has no usable 'name' — a declared UDT member must name itself; the "
|
||||
+ "WHOLE tag is rejected (BadNodeIdUnknown).";
|
||||
}
|
||||
|
||||
if (TagConfigJson.DescribeInvalidEnum<AbCipDataType>(member, "dataType") is { } dataTypeWarning)
|
||||
{
|
||||
return $"AbCip {label}: {dataTypeWarning} — the WHOLE tag is rejected (BadNodeIdUnknown).";
|
||||
}
|
||||
}
|
||||
|
||||
return null;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// String-input overload of <see cref="DescribeInvalidMember(JsonElement)"/>, for the AdminUI
|
||||
/// authoring model — which holds a mutable <c>JsonObject</c> key bag rather than a
|
||||
/// <see cref="JsonElement"/> and so reaches the same rule through a different door. Never throws: a
|
||||
/// blank / unparseable / non-object blob draws nothing here, because those shapes are the OTHER
|
||||
/// gates' business, not the member rule's.
|
||||
/// </summary>
|
||||
/// <param name="tagConfig">The authored equipment-tag TagConfig JSON.</param>
|
||||
/// <returns>The warning text, or <see langword="null"/> when the members read.</returns>
|
||||
public static string? DescribeInvalidMember(string? tagConfig)
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(tagConfig)) return null;
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(tagConfig);
|
||||
return doc.RootElement.ValueKind == JsonValueKind.Object
|
||||
? DescribeInvalidMember(doc.RootElement)
|
||||
: null;
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
}
|
||||
|
||||
private static bool ReadBool(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.True;
|
||||
|
||||
|
||||
+60
-5
@@ -119,16 +119,40 @@ public static class AbLegacyTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns on a present-but-invalid <c>dataType</c> (silently
|
||||
/// defaulted by the lenient runtime) and on a structurally unparseable TagConfig. Empty when clean
|
||||
/// or not an equipment-tag object. Never throws.
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection — the mapper only copies it
|
||||
/// onto <see cref="AbLegacyTagDefinition.Name"/> and never validates it.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns for a blob <see cref="FromTagConfig"/> would
|
||||
/// <b>reject</b> — a structurally unparseable or non-object document, an absent / non-string /
|
||||
/// blank <c>address</c>, or a present-but-invalid <c>dataType</c> (the runtime enum read is STRICT
|
||||
/// since R2-11 Phase C, so a typo rejects the tag). Such a tag is skipped by the driver and reads
|
||||
/// <c>BadNodeIdUnknown</c> forever. Empty when the mapper accepts the blob, when it is blank, or
|
||||
/// when it is not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The verdict comes from <see cref="FromTagConfig"/>, not from a mirror</b> (Gitea #551) — see
|
||||
/// <c>ModbusTagDefinitionFactory.Inspect</c>'s remarks for the full argument.
|
||||
/// <para>
|
||||
/// An <c>arrayLength</c> above <see cref="AbLegacyArray.MaxElements"/> is deliberately NOT
|
||||
/// warned about: the mapper CLAMPS it rather than rejecting, so the driver serves the tag. The
|
||||
/// AdminUI model refuses it at authoring because the un-clamped length also sets the OPC UA
|
||||
/// <c>ArrayDimensions</c>; a warning here could be promoted to a deploy ERROR and would then
|
||||
/// block a tag the runtime happily reads.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -138,16 +162,47 @@ public static class AbLegacyTagDefinitionFactory
|
||||
warnings.Add("AbLegacy TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<AbLegacyDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
|
||||
DescribeRejection(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("AbLegacy TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
if (warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"AbLegacy TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Runs only after the mapper has already refused, so it can never invent strictness.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("address", out var addr) || addr.ValueKind != JsonValueKind.String)
|
||||
{
|
||||
warnings.Add(
|
||||
"AbLegacy TagConfig has no string 'address' (e.g. N7:0, B3:1/2, F8:5) — the driver will "
|
||||
+ "skip this tag and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
else if (string.IsNullOrWhiteSpace(addr.GetString()))
|
||||
{
|
||||
warnings.Add("AbLegacy TagConfig has a blank 'address' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (TagConfigJson.DescribeInvalidEnum<AbLegacyDataType>(root, "dataType") is { } w) warnings.Add(w);
|
||||
}
|
||||
|
||||
private static int ReadInt(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.Number
|
||||
&& e.TryGetInt32(out var v) ? v : 0;
|
||||
|
||||
@@ -95,10 +95,33 @@ public static class FocasTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2, 05/UNDER-1): warns on a present-but-invalid <c>dataType</c>
|
||||
/// (silently defaulted by the lenient runtime), on an authored <c>writable:true</c> (the FOCAS wire
|
||||
/// is read-only — <c>WriteAsync</c> always returns <c>BadNotWritable</c>), and on a structurally
|
||||
/// unparseable TagConfig. Empty when clean or not an equipment-tag object. Never throws.
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection — the mapper only copies it
|
||||
/// onto <see cref="FocasTagDefinition.Name"/> and never validates it.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2, 05/UNDER-1). Two kinds of warning, and the distinction is
|
||||
/// load-bearing:
|
||||
/// <list type="bullet">
|
||||
/// <item>
|
||||
/// <b>Rejections</b> — a blob <see cref="FromTagConfig"/> would refuse: an unparseable or
|
||||
/// non-object document, an absent / non-string / blank <c>address</c>, or a
|
||||
/// present-but-invalid <c>dataType</c> (the runtime enum read is STRICT since R2-11 Phase C,
|
||||
/// so a typo rejects the tag). The driver skips such a tag and it reads
|
||||
/// <c>BadNodeIdUnknown</c> forever. These are diagnosed only when the mapper has actually
|
||||
/// refused, so this gate can never be stricter than the runtime (Gitea #551).
|
||||
/// </item>
|
||||
/// <item>
|
||||
/// <b>Advisories</b> — an <em>accepted</em> blob that still will not work: an unparseable
|
||||
/// FOCAS address (#540; the mapper only requires a non-blank string, the driver's own init
|
||||
/// then drops it) and an authored <c>writable:true</c> (the FOCAS wire is read-only, so
|
||||
/// <c>WriteAsync</c> always returns <c>BadNotWritable</c>). These run whether or not the
|
||||
/// blob parses, which is why FOCAS does not simply return empty on accept.
|
||||
/// </item>
|
||||
/// </list>
|
||||
/// Empty for a clean, accepted blob, for a blank one, or for one that is not an equipment-tag
|
||||
/// object. Never throws.
|
||||
/// </summary>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
@@ -106,6 +129,11 @@ public static class FocasTagDefinitionFactory
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: only a blob the driver REFUSES gets a rejection diagnosis. The advisories below
|
||||
// apply either way — see the summary.
|
||||
var accepted = FromTagConfig(reference, InspectionRawPath, out _);
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -115,30 +143,72 @@ public static class FocasTagDefinitionFactory
|
||||
warnings.Add("FOCAS TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<FocasDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
// Gitea #540: an address the driver cannot parse is skipped at init and reads
|
||||
// BadNodeIdUnknown forever, while driver health stays Healthy with zero errors. The
|
||||
// AdminUI modal rejects it outright; this covers the paths that never touch the modal
|
||||
// (CSV import, the API) by at least surfacing it on the deployment.
|
||||
if (root.TryGetProperty("address", out var addr)
|
||||
&& addr.ValueKind == JsonValueKind.String
|
||||
&& addr.GetString() is { } address
|
||||
&& !string.IsNullOrWhiteSpace(address)
|
||||
&& FocasAddress.TryParse(address) is null)
|
||||
{
|
||||
warnings.Add(
|
||||
$"FOCAS address '{address.Trim()}' is not parseable (expected X0.0 / R100, " +
|
||||
"PARAM:1020, MACRO:500 or FIXED:Identity/SeriesNumber) — the driver will skip " +
|
||||
"this tag at startup and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
if (root.TryGetProperty("writable", out var wr) && wr.ValueKind == JsonValueKind.True)
|
||||
warnings.Add("FOCAS wire is read-only — an authored 'writable:true' still fails at the wire with BadNotWritable.");
|
||||
|
||||
if (!accepted) DescribeRejection(root, warnings);
|
||||
DescribeAdvisories(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("FOCAS TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
if (!accepted && warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"FOCAS TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Runs only after the mapper has already refused, so it can never invent strictness.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("address", out var addr) || addr.ValueKind != JsonValueKind.String)
|
||||
{
|
||||
warnings.Add(
|
||||
"FOCAS TagConfig has no string 'address' — the driver will skip this tag and it will read "
|
||||
+ "BadNodeIdUnknown.");
|
||||
}
|
||||
else if (string.IsNullOrWhiteSpace(addr.GetString()))
|
||||
{
|
||||
warnings.Add("FOCAS TagConfig has a blank 'address' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (TagConfigJson.DescribeInvalidEnum<FocasDataType>(root, "dataType") is { } w) warnings.Add(w);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Warnings about a blob the mapper ACCEPTS but the driver still cannot serve as authored — see the
|
||||
/// "advisories" bullet on <see cref="Inspect"/>.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeAdvisories(JsonElement root, List<string> warnings)
|
||||
{
|
||||
// Gitea #540: an address the driver cannot parse is skipped at init and reads BadNodeIdUnknown
|
||||
// forever, while driver health stays Healthy with zero errors. The AdminUI modal rejects it
|
||||
// outright; this covers the paths that never touch the modal (CSV import, the API).
|
||||
if (root.TryGetProperty("address", out var addr)
|
||||
&& addr.ValueKind == JsonValueKind.String
|
||||
&& addr.GetString() is { } address
|
||||
&& !string.IsNullOrWhiteSpace(address)
|
||||
&& FocasAddress.TryParse(address) is null)
|
||||
{
|
||||
warnings.Add(
|
||||
$"FOCAS address '{address.Trim()}' is not parseable (expected X0.0 / R100, " +
|
||||
"PARAM:1020, MACRO:500 or FIXED:Identity/SeriesNumber) — the driver will skip " +
|
||||
"this tag at startup and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
if (root.TryGetProperty("writable", out var wr) && wr.ValueKind == JsonValueKind.True)
|
||||
warnings.Add("FOCAS wire is read-only — an authored 'writable:true' still fails at the wire with BadNotWritable.");
|
||||
}
|
||||
}
|
||||
|
||||
+104
-14
@@ -130,18 +130,41 @@ public static class ModbusTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection of an equipment-tag <c>TagConfig</c> blob (05/CONV-2). Returns
|
||||
/// human-readable warnings for present-but-invalid enum values (<c>region</c> / <c>dataType</c> /
|
||||
/// <c>byteOrder</c> — which the lenient runtime silently defaults) and for a structurally
|
||||
/// unparseable TagConfig (which the runtime turns into a silent <c>BadNodeIdUnknown</c>). Empty when
|
||||
/// the blob is clean or is not an equipment-tag TagConfig object. Never throws.
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection. The mapper only copies it
|
||||
/// onto <see cref="ModbusTagDefinition.Name"/> and never validates it, so inspection is free to pass
|
||||
/// a placeholder — the deploy gate is inspecting a blob, not a placed tag.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection of an equipment-tag <c>TagConfig</c> blob (05/CONV-2). Returns
|
||||
/// human-readable warnings for a blob <see cref="FromTagConfig"/> would <b>reject</b> — a
|
||||
/// structurally unparseable or non-object document, an absent <c>region</c>, an absent or
|
||||
/// out-of-range <c>address</c>, a present-but-invalid <c>region</c> / <c>dataType</c> /
|
||||
/// <c>byteOrder</c> / <c>stringByteOrder</c> (each rejects the tag: the runtime enum reads are
|
||||
/// STRICT since R2-11 Phase C), or a type-dependent guard (<c>String</c> with no
|
||||
/// <c>stringLength</c>, <c>BitInRegister</c> with a <c>bitIndex</c> outside 0–15). Such a tag is
|
||||
/// skipped by the driver and reads <c>BadNodeIdUnknown</c> forever. Empty when the mapper accepts
|
||||
/// the blob, when it is blank, or when it is not an equipment-tag TagConfig object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The verdict comes from <see cref="FromTagConfig"/>, not from a mirror</b> (Gitea #551). The
|
||||
/// rule this gate must never break is being stricter than the runtime — a blob the driver serves
|
||||
/// must not draw a warning calling it invalid — and running the mapper first makes that structural
|
||||
/// rather than a promise. It also closes the opposite gap: the previous hand-list of enum checks
|
||||
/// was silent for every rejection cause that was not on it (an absent <c>region</c>, a bad
|
||||
/// <c>address</c>, <c>stringByteOrder</c>), so a tag the driver refuses deployed clean.
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing. See the remarks.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -151,23 +174,90 @@ public static class ModbusTagDefinitionFactory
|
||||
warnings.Add("Modbus TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
foreach (var w in new[]
|
||||
{
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusRegion>(root, "region"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusDataType>(root, "dataType"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusByteOrder>(root, "byteOrder"),
|
||||
})
|
||||
{
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
|
||||
DescribeRejection(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("Modbus TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
// Backstop: the mapper refused for a reason nothing above names (it also swallows FormatException
|
||||
// and InvalidOperationException). Saying so beats reporting a clean blob the driver will skip.
|
||||
if (warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Every branch mirrors a <c>return false</c> there — and it runs only after the mapper
|
||||
/// has already refused, so it can never invent strictness of its own.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("region", out _))
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus TagConfig has no 'region' — every Modbus tag must name one (valid: "
|
||||
+ string.Join(", ", Enum.GetNames<ModbusRegion>())
|
||||
+ "); the driver will skip this tag and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
if (!root.TryGetProperty("address", out var addr))
|
||||
{
|
||||
warnings.Add("Modbus TagConfig has no 'address' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
else if (addr.ValueKind != JsonValueKind.Number
|
||||
|| !addr.TryGetInt32(out var address)
|
||||
|| address < 0 || address > ushort.MaxValue)
|
||||
{
|
||||
warnings.Add(
|
||||
$"value '{addr.GetRawText()}' for 'address' is not a Modbus register address (an integer "
|
||||
+ $"0–{ushort.MaxValue}); the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
// Strict enums, in the order FromTagConfig reads them. stringByteOrder is read as strictly as its
|
||||
// three siblings, and was the one the previous hand-list forgot (Gitea #551).
|
||||
foreach (var w in new[]
|
||||
{
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusRegion>(root, "region"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusDataType>(root, "dataType"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusByteOrder>(root, "byteOrder"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusStringByteOrder>(root, "stringByteOrder"),
|
||||
})
|
||||
{
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
|
||||
// Type-dependent guards. The byte/ushort NARROWING is part of the rule, not an accident of the
|
||||
// mapper: it reads `(byte)bitIndex` / `(ushort)stringLength`, so 256 is bit 0 and is ACCEPTED.
|
||||
// Describing the un-narrowed value here would call a blob invalid that the driver serves.
|
||||
if (!TagConfigJson.TryReadEnumStrict(root, "dataType", ModbusDataType.Int16, out var dataType)) return;
|
||||
|
||||
if (dataType == ModbusDataType.String && (ushort)ReadInt(root, "stringLength") < 1)
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus String tag has no 'stringLength' of at least 1 — a zero-length string reads zero "
|
||||
+ "registers, which is an illegal Modbus request, so the tag is rejected (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (dataType == ModbusDataType.BitInRegister && (byte)ReadInt(root, "bitIndex") > 15)
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus BitInRegister tag has a 'bitIndex' outside 0–15 — the bit mask would overflow a "
|
||||
+ "16-bit register, so the tag is rejected (BadNodeIdUnknown).");
|
||||
}
|
||||
}
|
||||
|
||||
private static int ReadInt(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.Number
|
||||
&& e.TryGetInt32(out var v) ? v : 0;
|
||||
|
||||
@@ -205,19 +205,46 @@ public static class MqttTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection of an equipment-tag <c>TagConfig</c> blob. Returns human-readable
|
||||
/// warnings for a structurally unparseable blob (which the runtime turns into a silent
|
||||
/// <c>BadNodeIdUnknown</c>), for present-but-invalid <c>payloadFormat</c> / <c>dataType</c> /
|
||||
/// <c>qos</c> values, and for a <b>wildcard</b> tag topic (a tag bound to <c>+</c> / <c>#</c>
|
||||
/// would receive values from many topics — ambiguous, and almost never what the operator meant).
|
||||
/// Empty when the blob is clean or is not an equipment-tag TagConfig object. Never throws.
|
||||
/// The RawPath handed to the mappers during inspection — they only copy it onto
|
||||
/// <see cref="MqttTagDefinition.Name"/> and never validate it.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection of an equipment-tag <c>TagConfig</c> blob. Two kinds of warning:
|
||||
/// <list type="bullet">
|
||||
/// <item>
|
||||
/// <b>Rejections</b> — a blob NEITHER runtime mapper would read: an unparseable or
|
||||
/// non-object document, present-but-invalid <c>payloadFormat</c> / <c>dataType</c> /
|
||||
/// <c>qos</c> values (all read strictly), or an address that names neither a Plain
|
||||
/// <c>topic</c> nor a complete Sparkplug <c>groupId</c>/<c>edgeNodeId</c>/<c>metricName</c>
|
||||
/// tuple. Such a tag is skipped by the driver and reads <c>BadNodeIdUnknown</c> forever.
|
||||
/// </item>
|
||||
/// <item>
|
||||
/// <b>Advisory</b> — a <b>wildcard</b> tag topic (<c>+</c> / <c>#</c>). The mapper
|
||||
/// deliberately ACCEPTS it (ambiguous, not unparseable), so this runs either way.
|
||||
/// </item>
|
||||
/// </list>
|
||||
/// Empty for a clean, readable blob, for a blank one, or for one that is not an equipment-tag
|
||||
/// TagConfig object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The accept gate is the UNION of the two mappers</b> (Gitea #551), because <c>Inspect</c> is
|
||||
/// handed a blob with no mode: the driver's <see cref="MqttMode"/> decides which of
|
||||
/// <see cref="FromTagConfig"/> / <see cref="FromSparkplugTagConfig"/> reads it, and nothing about a
|
||||
/// tag row says which. Gating on the Plain mapper alone would warn that every correctly-authored
|
||||
/// Sparkplug tag has no topic — a gate stricter than the runtime, the one thing it must never be.
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
var accepted = FromTagConfig(reference, InspectionRawPath, out _)
|
||||
|| FromSparkplugTagConfig(reference, InspectionRawPath, out _);
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -227,16 +254,11 @@ public static class MqttTagDefinitionFactory
|
||||
warnings.Add("Mqtt TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
foreach (var w in new[]
|
||||
{
|
||||
TagConfigJson.DescribeInvalidEnum<MqttPayloadFormat>(root, "payloadFormat"),
|
||||
TagConfigJson.DescribeInvalidEnum<DriverDataType>(root, "dataType"),
|
||||
DescribeInvalidQos(root),
|
||||
})
|
||||
{
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
var topic = ReadString(root, "topic");
|
||||
|
||||
if (!accepted) DescribeRejection(root, warnings);
|
||||
|
||||
// Advisory — the mappers accept a wildcard topic on purpose; see the summary.
|
||||
var topic = ReadString(root, MqttTagConfigKeys.Topic);
|
||||
if (topic.IndexOfAny(TopicWildcards) >= 0)
|
||||
{
|
||||
warnings.Add(
|
||||
@@ -247,10 +269,53 @@ public static class MqttTagDefinitionFactory
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("Mqtt TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
if (!accepted && warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"Mqtt TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why BOTH mappers refused an object-rooted blob. The strict-field checks are shared by
|
||||
/// the two shapes; the address check names what each shape needed. Runs only after both mappers have
|
||||
/// already refused, so it can never invent strictness.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
foreach (var w in new[]
|
||||
{
|
||||
TagConfigJson.DescribeInvalidEnum<MqttPayloadFormat>(root, "payloadFormat"),
|
||||
TagConfigJson.DescribeInvalidEnum<DriverDataType>(root, "dataType"),
|
||||
DescribeInvalidQos(root),
|
||||
})
|
||||
{
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
|
||||
// Address: Plain needs a topic, Sparkplug needs the whole binding tuple. Neither is satisfied, or
|
||||
// one of the strict fields above already refused both — only say it when the address is the cause.
|
||||
var hasTopic = !string.IsNullOrWhiteSpace(ReadString(root, MqttTagConfigKeys.Topic));
|
||||
var hasSparkplugTuple = !string.IsNullOrWhiteSpace(ReadString(root, MqttTagConfigKeys.GroupId))
|
||||
&& !string.IsNullOrWhiteSpace(ReadString(root, MqttTagConfigKeys.EdgeNodeId))
|
||||
&& !string.IsNullOrWhiteSpace(ReadString(root, MqttTagConfigKeys.MetricName));
|
||||
if (!hasTopic && !hasSparkplugTuple)
|
||||
{
|
||||
warnings.Add(
|
||||
"Mqtt TagConfig names no address — a Plain-mode tag needs a 'topic', a Sparkplug B tag "
|
||||
+ "needs 'groupId' + 'edgeNodeId' + 'metricName'. The driver will skip this tag and it "
|
||||
+ "will read BadNodeIdUnknown.");
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Strict <c>qos</c> read, mirroring <see cref="TagConfigJson.TryReadEnumStrict{TEnum}"/>'s
|
||||
/// absent / valid / present-but-invalid split: absent ⇒ <see langword="null"/> (the driver-level
|
||||
|
||||
@@ -111,16 +111,61 @@ public static class S7TagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns on a present-but-invalid <c>dataType</c> (silently
|
||||
/// defaulted by the lenient runtime) and on a structurally unparseable TagConfig (a silent
|
||||
/// <c>BadNodeIdUnknown</c> at runtime). Empty when clean or not an equipment-tag object. Never throws.
|
||||
/// The <c>TagConfig</c> key carrying the S7 data type. Shared with the AdminUI authoring model so
|
||||
/// "does the blob declare a type?" is asked of one spelling, not two (Gitea #551).
|
||||
/// </summary>
|
||||
public const string DataTypeKey = "dataType";
|
||||
|
||||
/// <summary>
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection — the mapper only copies it
|
||||
/// onto <see cref="S7TagDefinition.Name"/> and never validates it.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// <b>The single authority on whether an S7 blob DECLARES a data type</b>, consulted by
|
||||
/// <see cref="Inspect"/> and by the AdminUI's <c>S7TagConfigModel.Validate</c> alike.
|
||||
/// <para>
|
||||
/// S7 is the one driver in the fleet whose reader <b>requires the key to be present</b>
|
||||
/// (<see cref="FromTagConfig"/> refuses a blob without it, where every sibling falls back to a
|
||||
/// default), so a hand-authored / CSV / API blob that omits it used to pass both gates and die
|
||||
/// at the driver with <c>BadNodeIdUnknown</c> — Gitea #551 item 2.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// Presence is judged on the KEY, not on the value: a non-string token
|
||||
/// (<c>"dataType": 8</c>) satisfies the presence check and is then treated as absent by
|
||||
/// <see cref="TagConfigJson.TryReadEnumStrict{TEnum}"/>, so the blob is ACCEPTED as
|
||||
/// <see cref="S7DataType.Int16"/>. Judging the value here would make this gate stricter than
|
||||
/// the reader.
|
||||
/// </para>
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <returns><see langword="true"/> when the blob carries a <c>dataType</c> key of any kind.</returns>
|
||||
public static bool DeclaresDataType(JsonElement root) => root.TryGetProperty(DataTypeKey, out _);
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns for a blob <see cref="FromTagConfig"/> would
|
||||
/// <b>reject</b> — a structurally unparseable or non-object document, an absent / non-string /
|
||||
/// blank <c>address</c>, an <b>absent</b> <c>dataType</c> (see <see cref="DeclaresDataType"/>), a
|
||||
/// present-but-invalid <c>dataType</c> (the runtime enum read is STRICT since R2-11 Phase C, so a
|
||||
/// typo rejects the tag), or an out-of-range <c>stringLength</c> on a <c>String</c> tag. Such a tag
|
||||
/// is skipped by the driver and reads <c>BadNodeIdUnknown</c> forever. Empty when the mapper accepts
|
||||
/// the blob, when it is blank, or when it is not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The verdict comes from <see cref="FromTagConfig"/>, not from a mirror</b> (Gitea #551) — see
|
||||
/// <c>ModbusTagDefinitionFactory.Inspect</c>'s remarks for the full argument.
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -130,16 +175,67 @@ public static class S7TagDefinitionFactory
|
||||
warnings.Add("S7 TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<S7DataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
|
||||
DescribeRejection(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("S7 TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
if (warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"S7 TagConfig was rejected by the driver's tag reader — the driver will skip this tag and "
|
||||
+ "it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Runs only after the mapper has already refused, so it can never invent strictness.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("address", out var addrEl) || addrEl.ValueKind != JsonValueKind.String)
|
||||
{
|
||||
warnings.Add(
|
||||
"S7 TagConfig has no string 'address' (e.g. DB1.DBW0, M0.0, I0.0, QD4) — the driver will "
|
||||
+ "skip this tag and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
else if (string.IsNullOrWhiteSpace(addrEl.GetString()))
|
||||
{
|
||||
warnings.Add("S7 TagConfig has a blank 'address' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (!DeclaresDataType(root))
|
||||
{
|
||||
warnings.Add(
|
||||
"S7 TagConfig has no 'dataType' — the S7 reader REQUIRES the key to be present (unlike its "
|
||||
+ "sibling drivers, which default it), so the driver will skip this tag and it will read "
|
||||
+ "BadNodeIdUnknown. Valid: " + string.Join(", ", Enum.GetNames<S7DataType>()) + ".");
|
||||
}
|
||||
|
||||
if (TagConfigJson.DescribeInvalidEnum<S7DataType>(root, DataTypeKey) is { } w) warnings.Add(w);
|
||||
|
||||
if (TagConfigJson.TryReadEnumStrict(root, DataTypeKey, S7DataType.Int16, out var dataType)
|
||||
&& dataType == S7DataType.String)
|
||||
{
|
||||
var stringLength = ReadInt(root, "stringLength");
|
||||
if (stringLength < 0 || stringLength > MaxStringLength)
|
||||
{
|
||||
warnings.Add(
|
||||
$"S7 String tag has a 'stringLength' of {stringLength} — an S7 string is 0–"
|
||||
+ $"{MaxStringLength} characters, so the tag is rejected (BadNodeIdUnknown).");
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
private static int ReadInt(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.Number
|
||||
&& e.TryGetInt32(out var v) ? v : 0;
|
||||
|
||||
+63
-5
@@ -109,16 +109,34 @@ public static class TwinCATTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns on a present-but-invalid <c>dataType</c> (silently
|
||||
/// defaulted by the lenient runtime) and on a structurally unparseable TagConfig. Empty when clean
|
||||
/// or not an equipment-tag object. Never throws.
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection — the mapper only copies it
|
||||
/// onto <see cref="TwinCATTagDefinition.Name"/> and never validates it.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection (05/CONV-2): warns for a blob <see cref="FromTagConfig"/> would
|
||||
/// <b>reject</b> — a structurally unparseable or non-object document, an absent / non-string /
|
||||
/// blank <c>symbolPath</c>, a present-but-invalid <c>dataType</c> (the runtime enum read is STRICT
|
||||
/// since R2-11 Phase C, so a typo rejects the tag), or the unsupported
|
||||
/// <see cref="TwinCATDataType.Structure"/> type. Such a tag is skipped by the driver and reads
|
||||
/// <c>BadNodeIdUnknown</c> forever. Empty when the mapper accepts the blob, when it is blank, or
|
||||
/// when it is not an equipment-tag object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The verdict comes from <see cref="FromTagConfig"/>, not from a mirror</b> (Gitea #551) — see
|
||||
/// <c>ModbusTagDefinitionFactory.Inspect</c>'s remarks for the full argument.
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -128,16 +146,56 @@ public static class TwinCATTagDefinitionFactory
|
||||
warnings.Add("TwinCAT TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
var w = TagConfigJson.DescribeInvalidEnum<TwinCATDataType>(root, "dataType");
|
||||
if (w is not null) warnings.Add(w);
|
||||
|
||||
DescribeRejection(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("TwinCAT TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
if (warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"TwinCAT TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Runs only after the mapper has already refused, so it can never invent strictness.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("symbolPath", out var symbol) || symbol.ValueKind != JsonValueKind.String)
|
||||
{
|
||||
warnings.Add(
|
||||
"TwinCAT TagConfig has no string 'symbolPath' (e.g. MAIN.bStart) — the driver will skip "
|
||||
+ "this tag and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
else if (string.IsNullOrWhiteSpace(symbol.GetString()))
|
||||
{
|
||||
warnings.Add("TwinCAT TagConfig has a blank 'symbolPath' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (TagConfigJson.DescribeInvalidEnum<TwinCATDataType>(root, "dataType") is { } w) warnings.Add(w);
|
||||
|
||||
if (TagConfigJson.TryReadEnumStrict(root, "dataType", TwinCATDataType.DInt, out var dataType)
|
||||
&& dataType == TwinCATDataType.Structure)
|
||||
{
|
||||
warnings.Add(
|
||||
"TwinCAT 'dataType' is Structure — the driver does not support UDT / FB-instance tags and "
|
||||
+ "rejects them (BadNodeIdUnknown). Declare the atomic-typed members instead, or use "
|
||||
+ "EnableControllerBrowse to discover them individually.");
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Reads the optional 1-D array length: <c>arrayLength</c> (a positive int32; values above
|
||||
/// <see cref="int.MaxValue"/> are treated as absent/scalar) honoured ONLY when <c>isArray</c>
|
||||
|
||||
@@ -19,6 +19,14 @@ namespace ZB.MOM.WW.OtOpcUa.AdminUI.Uns;
|
||||
/// columns. A typed column therefore <b>wins</b> over a conflicting key carried in the <c>TagConfigJson</c>
|
||||
/// fallback; the review model flags when that override happened so the operator sees it.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// The assembled blob is then put to the driver's own <see cref="TagConfigValidator"/> (Gitea #551): the
|
||||
/// typed columns were always strictly parsed, but the free-form <c>TagConfigJson</c> column reached the
|
||||
/// database unread, so a CSV could author a tag the driver rejects — one that deploys clean and reads
|
||||
/// <c>BadNodeIdUnknown</c> forever. A failing row is an <b>error</b>, blocking the all-or-nothing commit;
|
||||
/// it is never silently skipped. This check is for the operator's benefit (it names the row before
|
||||
/// commit); the guarantee lives in <see cref="IRawTreeService.ImportTagsAsync"/>, which re-runs it.
|
||||
/// </para>
|
||||
/// </summary>
|
||||
public static class RawTagCsvMapper
|
||||
{
|
||||
@@ -84,7 +92,7 @@ public static class RawTagCsvMapper
|
||||
continue;
|
||||
}
|
||||
|
||||
reviewed.Add(BuildRow(r, headers, headerIndex, cells, map, groupPathPrefix));
|
||||
reviewed.Add(BuildRow(r, headers, headerIndex, cells, driverType, map, groupPathPrefix));
|
||||
}
|
||||
|
||||
FlagDuplicates(reviewed);
|
||||
@@ -96,6 +104,7 @@ public static class RawTagCsvMapper
|
||||
string[] headers,
|
||||
IReadOnlyDictionary<string, int> headerIndex,
|
||||
string[] cells,
|
||||
string driverType,
|
||||
CsvDriverTagMap? map,
|
||||
string? groupPathPrefix)
|
||||
{
|
||||
@@ -193,6 +202,19 @@ public static class RawTagCsvMapper
|
||||
// Alarm flags — an alarm is authored iff Alarm.AlarmType is present.
|
||||
json = ApplyAlarm(json, Cell("Alarm.AlarmType"), Cell("Alarm.Severity"), Cell("Alarm.HistorizeToAveva"));
|
||||
|
||||
// The driver-typed config gate, on the FINAL assembled blob (Gitea #551 item 1). Until this,
|
||||
// the typed columns above were strictly parsed but the free-form TagConfigJson column was not
|
||||
// checked at all, so a CSV could import a blob the driver rejects — a tag that deploys clean
|
||||
// and then reads BadNodeIdUnknown forever. Surfacing it here, on the staged review row, is what
|
||||
// lets the operator SEE which row is wrong before committing; IRawTreeService.ImportTagsAsync
|
||||
// re-checks it as the actual guarantee (a form/grid cannot cover the API or a future caller).
|
||||
// A rejected row is an ERROR, never a skip: the commit is all-or-nothing, and "skipped" would
|
||||
// claim the tag is already present.
|
||||
if (TagConfigValidator.Validate(driverType, json) is { } configError)
|
||||
{
|
||||
return Invalid(rowNumber, cells, $"TagConfig: {configError}");
|
||||
}
|
||||
|
||||
var importRow = new RawTagImportRow(groupPath, new RawTagInput(name, dataType, access, writeIdempotent, pollGroupId, json));
|
||||
|
||||
return new RawCsvReviewRow
|
||||
|
||||
@@ -1,5 +1,6 @@
|
||||
using System.Text.Json;
|
||||
using Microsoft.EntityFrameworkCore;
|
||||
using ZB.MOM.WW.OtOpcUa.AdminUI.Uns.TagEditors;
|
||||
using ZB.MOM.WW.OtOpcUa.Commons.Types;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration.Entities;
|
||||
@@ -834,6 +835,9 @@ public sealed class RawTreeService(IDbContextFactory<OtOpcUaConfigDbContext> dbF
|
||||
t => t.DeviceId == deviceId && t.TagGroupId == tagGroupId && t.Name == input.Name, ct))
|
||||
return new UnsMutationResult(false, $"A tag named '{input.Name}' already exists here.");
|
||||
|
||||
if (await ValidateTagConfigAsync(db, deviceId, tagConfig, ct) is { } configError)
|
||||
return new UnsMutationResult(false, configError);
|
||||
|
||||
var id = NewId("TAG");
|
||||
db.Tags.Add(new Tag
|
||||
{
|
||||
@@ -872,6 +876,9 @@ public sealed class RawTreeService(IDbContextFactory<OtOpcUaConfigDbContext> dbF
|
||||
&& t.Name == input.Name && t.TagId != tagId, ct))
|
||||
return new UnsMutationResult(false, $"A tag named '{input.Name}' already exists here.");
|
||||
|
||||
if (await ValidateTagConfigAsync(db, entity.DeviceId, tagConfig, ct) is { } configError)
|
||||
return new UnsMutationResult(false, configError);
|
||||
|
||||
db.Entry(entity).Property(e => e.RowVersion).OriginalValue = rowVersion;
|
||||
entity.Name = input.Name;
|
||||
entity.DataType = input.DataType;
|
||||
@@ -902,6 +909,10 @@ public sealed class RawTreeService(IDbContextFactory<OtOpcUaConfigDbContext> dbF
|
||||
if (!await db.Devices.AnyAsync(dev => dev.DeviceId == deviceId, ct))
|
||||
return new RawTagImportResult(0, new[] { $"Device '{deviceId}' not found." });
|
||||
|
||||
// The device's driver type, resolved ONCE: an import is per-device, and a device hangs off exactly
|
||||
// one driver, so every row in the batch is judged by the same driver's rules (Gitea #551 item 1).
|
||||
var driverType = await ResolveDriverTypeAsync(db, deviceId, ct);
|
||||
|
||||
// Existing groups on the device: a (parent-group-id | null, name) → group-id lookup we extend with
|
||||
// pending (auto-created) groups so a repeated path within the batch resolves to one group.
|
||||
var groupLookup = (await db.TagGroups.AsNoTracking()
|
||||
@@ -951,6 +962,15 @@ public sealed class RawTreeService(IDbContextFactory<OtOpcUaConfigDbContext> dbF
|
||||
continue;
|
||||
}
|
||||
|
||||
// The driver-typed config gate. A rejected row is an ERROR — the import is all-or-nothing, so
|
||||
// the batch inserts nothing and the row is NAMED; it is never skipped ("skipped" would claim
|
||||
// the tag is already present). See ValidateTagConfigAsync for why this lives in the service.
|
||||
if (TagConfigValidator.Validate(driverType, tagConfig) is { } configError)
|
||||
{
|
||||
errors.Add($"{rowLabel}: TagConfig: {configError}");
|
||||
continue;
|
||||
}
|
||||
|
||||
if (!takenNames.Add((groupId, row.Tag.Name)))
|
||||
{
|
||||
errors.Add($"{rowLabel}: a tag named '{row.Tag.Name}' already exists at that path.");
|
||||
@@ -1196,6 +1216,55 @@ public sealed class RawTreeService(IDbContextFactory<OtOpcUaConfigDbContext> dbF
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The driver-type string of the driver a device hangs off, or <see langword="null"/> when the
|
||||
/// device (or its driver) is gone. Joined in exactly as <c>LoadDeviceForEditAsync</c> does — a
|
||||
/// device carries no driver type of its own.
|
||||
/// </summary>
|
||||
/// <param name="db">The open context.</param>
|
||||
/// <param name="deviceId">The device whose driver type to resolve.</param>
|
||||
/// <param name="ct">Cancellation token.</param>
|
||||
/// <returns>The canonical driver-type string, or null.</returns>
|
||||
private static Task<string?> ResolveDriverTypeAsync(
|
||||
OtOpcUaConfigDbContext db, string deviceId, CancellationToken ct)
|
||||
=> db.Devices.AsNoTracking()
|
||||
.Where(dev => dev.DeviceId == deviceId)
|
||||
.Join(db.DriverInstances.AsNoTracking(),
|
||||
dev => dev.DriverInstanceId,
|
||||
drv => drv.DriverInstanceId,
|
||||
(dev, drv) => drv.DriverType)
|
||||
.FirstOrDefaultAsync(ct);
|
||||
|
||||
/// <summary>
|
||||
/// The driver-typed <c>TagConfig</c> gate, applied on the SERVER for every tag-writing path —
|
||||
/// create, update and bulk import alike (Gitea #551 item 1).
|
||||
/// <para>
|
||||
/// <b>It lives here rather than in the modals because a form cannot be the guarantee.</b> The
|
||||
/// tag modal and the manual-entry grid already run <see cref="TagConfigValidator"/> for fast
|
||||
/// feedback, but the CSV import did not, and the API and any future caller reach none of them —
|
||||
/// so a blob the driver rejects could be persisted, deploy clean, and read
|
||||
/// <c>BadNodeIdUnknown</c> forever. This repo also has no bUnit, so a rule only a page enforces
|
||||
/// is a rule no test can reach.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// The rule itself is not stated here: <see cref="TagConfigValidator"/> dispatches to the
|
||||
/// driver's typed model, which in turn asks the driver's own reader. An unmapped driver type
|
||||
/// (Galaxy) validates to null, exactly as it does in the modals.
|
||||
/// </para>
|
||||
/// </summary>
|
||||
/// <param name="db">The open context.</param>
|
||||
/// <param name="deviceId">The device the tag belongs to (supplies the driver type).</param>
|
||||
/// <param name="tagConfig">The normalised TagConfig JSON about to be persisted.</param>
|
||||
/// <param name="ct">Cancellation token.</param>
|
||||
/// <returns>An operator-facing error, or <see langword="null"/> when the config is acceptable.</returns>
|
||||
private static async Task<string?> ValidateTagConfigAsync(
|
||||
OtOpcUaConfigDbContext db, string deviceId, string tagConfig, CancellationToken ct)
|
||||
{
|
||||
var driverType = await ResolveDriverTypeAsync(db, deviceId, ct);
|
||||
var error = TagConfigValidator.Validate(driverType, tagConfig);
|
||||
return error is null ? null : $"TagConfig: {error}";
|
||||
}
|
||||
|
||||
/// <summary>Ordinal (case-sensitive) equality for a nullable-parent + name tag-group key.</summary>
|
||||
private sealed class GroupKeyComparer : IEqualityComparer<(string? Parent, string Name)>
|
||||
{
|
||||
|
||||
@@ -59,11 +59,23 @@ public sealed class AbCipTagConfigModel
|
||||
/// (<c>BadNodeIdUnknown</c>). Without this the blob would be accepted here, silently rewritten to
|
||||
/// <c>DInt</c> on save, and — on the CSV-import and API paths, which save it verbatim — deployed
|
||||
/// into a tag the driver skips (Gitea #549).
|
||||
/// <para>
|
||||
/// <b>Declared UDT members are checked too (Gitea #551), and the rule is not restated here.</b>
|
||||
/// The member rules are as strict as the top-level ones — one member with no <c>name</c> or a
|
||||
/// typo'd <c>dataType</c> rejects the WHOLE tag — but nothing on the authoring side saw them:
|
||||
/// this editor emits only <c>tagPath</c>/<c>dataType</c>/<c>writable</c>, so <c>members</c>
|
||||
/// rides <see cref="_bag"/> untouched from whatever hand-authored / CSV / API blob produced it.
|
||||
/// The verdict AND the wording come from
|
||||
/// <see cref="AbCipTagDefinitionFactory.DescribeInvalidMember(string)"/>, the same authority the
|
||||
/// driver's reader and the deploy gate consult, so this gate cannot drift from the runtime in
|
||||
/// either direction.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
/// <returns>An error message describing the validation failure, or <c>null</c> when valid.</returns>
|
||||
public string? Validate()
|
||||
{
|
||||
if (TagConfigJson.DescribeInvalidEnum<AbCipDataType>(_bag, "dataType") is { } dtError) { return dtError; }
|
||||
return string.IsNullOrWhiteSpace(TagPath) ? "Tag path is required." : null;
|
||||
if (string.IsNullOrWhiteSpace(TagPath)) { return "Tag path is required."; }
|
||||
return AbCipTagDefinitionFactory.DescribeInvalidMember(TagConfigJson.Serialize(_bag));
|
||||
}
|
||||
}
|
||||
|
||||
@@ -69,17 +69,26 @@ public sealed class ModbusTagConfigModel
|
||||
|
||||
/// <summary>Validation hook; returns an error message or null when the model is valid.</summary>
|
||||
/// <remarks>
|
||||
/// All three enums are read from the ORIGINAL key bag, not from the leniently-defaulted typed
|
||||
/// All FOUR enums are read from the ORIGINAL key bag, not from the leniently-defaulted typed
|
||||
/// fields above: <c>ModbusTagDefinitionFactory</c> reads each with <c>TryReadEnumStrict</c>, so a
|
||||
/// present-but-invalid string rejects the whole tag at the driver (<c>BadNodeIdUnknown</c>) where
|
||||
/// the load silently substitutes <c>HoldingRegisters</c>/<c>Int16</c>/<c>BigEndian</c>. Accepting
|
||||
/// one here would let the CSV-import and API paths — which save the blob verbatim — deploy a tag
|
||||
/// the driver skips (Gitea #549). Also note a <b>wrong-but-valid</b> region is not this gate's
|
||||
/// business: only a spelling the runtime cannot read is rejected.
|
||||
/// the load silently substitutes <c>HoldingRegisters</c>/<c>Int16</c>/<c>BigEndian</c>/
|
||||
/// <c>HighByteFirst</c>. Accepting one here would let the CSV-import and API paths — which save the
|
||||
/// blob verbatim — deploy a tag the driver skips (Gitea #549). Also note a <b>wrong-but-valid</b>
|
||||
/// region is not this gate's business: only a spelling the runtime cannot read is rejected.
|
||||
/// <para>
|
||||
/// <c>stringByteOrder</c> is the fourth (Gitea #551): the runtime has always read it as
|
||||
/// strictly as its three siblings, but this model — and the deploy gate's <c>Inspect</c> —
|
||||
/// checked only the other three, so a typo'd <c>stringByteOrder</c> passed BOTH gates and died
|
||||
/// at the driver. It is not in <see cref="ToJson"/>'s exposed-field list either, so it can only
|
||||
/// ever reach the bag from a hand-authored blob, a CSV import or the API — exactly the paths
|
||||
/// this gate exists for.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
/// <returns>An error message describing the validation failure, or <c>null</c> when the model is valid.</returns>
|
||||
public string? Validate()
|
||||
=> TagConfigJson.DescribeInvalidEnum<ModbusRegion>(_bag, "region")
|
||||
?? TagConfigJson.DescribeInvalidEnum<ModbusDataType>(_bag, "dataType")
|
||||
?? TagConfigJson.DescribeInvalidEnum<ModbusByteOrder>(_bag, "byteOrder");
|
||||
?? TagConfigJson.DescribeInvalidEnum<ModbusByteOrder>(_bag, "byteOrder")
|
||||
?? TagConfigJson.DescribeInvalidEnum<ModbusStringByteOrder>(_bag, "stringByteOrder");
|
||||
}
|
||||
|
||||
@@ -22,6 +22,19 @@ public sealed class S7TagConfigModel
|
||||
|
||||
private JsonObject _bag = new();
|
||||
|
||||
// Whether the blob this model was LOADED FROM was missing the "dataType" key entirely — captured
|
||||
// because the lenient load above cannot tell "absent" from "present": both land on Int16. S7 is the one
|
||||
// driver whose reader REQUIRES the key (S7TagDefinitionFactory.DeclaresDataType), so a blob without one
|
||||
// is rejected outright and reads BadNodeIdUnknown; without this capture that blob validated clean
|
||||
// (Gitea #551). Same capture-the-as-loaded-shape pattern as MTConnectTagConfigModel's _rawDataType.
|
||||
//
|
||||
// It records a property of the SOURCE, so the default (false) is the honest answer for a model built by
|
||||
// object initialiser rather than loaded — RawBrowseCommitMapper does exactly that, and ToJson() then
|
||||
// writes the key from the typed DataType field. ToJson() likewise clears it: a blob that has been
|
||||
// re-serialised through this model always carries the key, so it can only ever be true on the FIRST
|
||||
// load of a blob authored elsewhere (hand-edited, CSV import, API).
|
||||
private bool _dataTypeMissingInSource;
|
||||
|
||||
/// <summary>Loads a model from a TagConfig JSON string, defaulting any absent field and retaining
|
||||
/// every original key (so fields this editor doesn't expose survive a load→save).</summary>
|
||||
/// <param name="json">The raw TagConfig JSON string, or null/empty for a fresh model.</param>
|
||||
@@ -32,9 +45,10 @@ public sealed class S7TagConfigModel
|
||||
return new S7TagConfigModel
|
||||
{
|
||||
Address = TagConfigJson.GetString(o, "address") ?? "",
|
||||
DataType = TagConfigJson.GetEnum(o, "dataType", S7DataType.Int16),
|
||||
DataType = TagConfigJson.GetEnum(o, S7TagDefinitionFactory.DataTypeKey, S7DataType.Int16),
|
||||
StringLength = TagConfigJson.GetInt(o, "stringLength"),
|
||||
Writable = TagConfigJson.GetBoolNullable(o, "writable"),
|
||||
_dataTypeMissingInSource = !o.ContainsKey(S7TagDefinitionFactory.DataTypeKey),
|
||||
_bag = o,
|
||||
};
|
||||
}
|
||||
@@ -45,7 +59,8 @@ public sealed class S7TagConfigModel
|
||||
public string ToJson()
|
||||
{
|
||||
TagConfigJson.Set(_bag, "address", Address.Trim());
|
||||
TagConfigJson.Set(_bag, "dataType", DataType);
|
||||
TagConfigJson.Set(_bag, S7TagDefinitionFactory.DataTypeKey, DataType);
|
||||
_dataTypeMissingInSource = false;
|
||||
TagConfigJson.Set(_bag, "stringLength", StringLength);
|
||||
TagConfigJson.Set(_bag, "writable", Writable);
|
||||
return TagConfigJson.Serialize(_bag);
|
||||
@@ -59,10 +74,36 @@ public sealed class S7TagConfigModel
|
||||
/// so a present-but-invalid string rejects the whole tag at the driver (<c>BadNodeIdUnknown</c>)
|
||||
/// where the load silently substitutes <c>Int16</c>. Accepting it here would let the CSV-import
|
||||
/// and API paths — which save the blob verbatim — deploy an unreadable tag (Gitea #549).
|
||||
/// <para>
|
||||
/// <b>An ABSENT <c>dataType</c> is rejected too (Gitea #551), and S7 is the only driver where
|
||||
/// that is right.</b> <c>S7TagDefinitionFactory.FromTagConfig</c> refuses a blob that does not
|
||||
/// carry the key at all — unique in the fleet, where every sibling falls back to a default — so
|
||||
/// such a tag deployed clean through both gates and then read <c>BadNodeIdUnknown</c> forever.
|
||||
/// Presence is judged on the key, not the value, matching
|
||||
/// <see cref="S7TagDefinitionFactory.DeclaresDataType"/>: a non-string token is present-enough
|
||||
/// for the reader, which then treats it as absent and accepts the tag as <c>Int16</c>.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>The one blob this can newly block in the modal is one that was already dead.</b> The
|
||||
/// typed editor pushes <see cref="ToJson"/> — which always writes <c>dataType</c> — only when a
|
||||
/// field CHANGES, so opening a legacy key-less blob and saving it untouched hands this method
|
||||
/// the as-loaded string. That save is refused, and correctly: the tag it would persist is one
|
||||
/// the driver already skips. Picking any data type in the editor writes the key and clears it.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public string? Validate()
|
||||
{
|
||||
if (TagConfigJson.DescribeInvalidEnum<S7DataType>(_bag, "dataType") is { } dtError) { return dtError; }
|
||||
return string.IsNullOrWhiteSpace(Address) ? "Address is required." : null;
|
||||
if (TagConfigJson.DescribeInvalidEnum<S7DataType>(_bag, S7TagDefinitionFactory.DataTypeKey) is { } dtError)
|
||||
{
|
||||
return dtError;
|
||||
}
|
||||
|
||||
if (string.IsNullOrWhiteSpace(Address)) { return "Address is required."; }
|
||||
|
||||
return _dataTypeMissingInSource
|
||||
? "A data type is required — the S7 driver rejects a tag whose TagConfig carries no "
|
||||
+ $"'{S7TagDefinitionFactory.DataTypeKey}' key (it would read BadNodeIdUnknown). Valid: "
|
||||
+ string.Join(", ", Enum.GetNames<S7DataType>()) + "."
|
||||
: null;
|
||||
}
|
||||
}
|
||||
|
||||
@@ -246,8 +246,11 @@ public sealed class AdminOperationsActor : ReceiveActor
|
||||
}
|
||||
|
||||
// R2-11 (05/CONV-2): deploy-time TagConfig strictness inspection over equipment tags. The
|
||||
// driver-typed EquipmentTagConfigInspector surfaces present-but-invalid enum values (which the
|
||||
// lenient runtime silently defaults) + structurally-unparseable TagConfig. In Warn mode
|
||||
// driver-typed EquipmentTagConfigInspector surfaces every blob the driver's own reader would
|
||||
// REJECT — a present-but-invalid enum value, an absent or malformed address field, a
|
||||
// structurally-unparseable TagConfig — each of which makes the driver skip the tag so it reads
|
||||
// BadNodeIdUnknown forever. (Pre-R2-11 Phase C the runtime silently defaulted a typo'd enum;
|
||||
// it has rejected the tag since, so these warnings describe rejections.) In Warn mode
|
||||
// (default) these are non-blocking (logged + appended to the accepted result Message); in Error
|
||||
// mode they fold into the reject list so a typo'd config cannot be re-deployed until fixed.
|
||||
// Running servers are untouched either way — the gate only sees re-deploys.
|
||||
|
||||
+11
-2
@@ -17,8 +17,17 @@ namespace ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
/// Deploy-time TagConfig inspection dispatched by <c>DriverType</c> (R2-11, 05/CONV-2). Mirrors the
|
||||
/// AdminUI <c>TagConfigValidator</c> shape: a case-insensitive map from the canonical driver-type string
|
||||
/// to that driver's lightweight <c>Contracts</c> parser <c>Inspect()</c>, returning human-readable
|
||||
/// warnings (present-but-invalid enum values that the lenient runtime silently defaults, plus
|
||||
/// structurally-unparseable TagConfig). Never throws.
|
||||
/// warnings. Never throws.
|
||||
/// <para><b>The warnings describe REJECTIONS, not silent defaults.</b> Every driver's runtime read has
|
||||
/// been strict since R2-11 Phase C (<c>TagConfigJson.TryReadEnumStrict</c>): a present-but-invalid enum
|
||||
/// value — like an absent or malformed address field, or an unparseable document — makes the reader
|
||||
/// refuse the whole tag, so the driver skips it and it reads <c>BadNodeIdUnknown</c> forever with the
|
||||
/// deployment otherwise green. That is what these warnings are for. (Before Phase C the runtime did
|
||||
/// silently substitute a default for a typo'd enum; the doc-comments here and on the per-driver
|
||||
/// <c>Inspect</c> methods still said so until Gitea #551.) Because a warning can be PROMOTED to a
|
||||
/// blocking error by <c>TagConfigValidationMode.Error</c>, each <c>Inspect</c> asks its driver's own
|
||||
/// reader for the verdict and only explains a refusal — never restating the rule, and so never able to
|
||||
/// be stricter than the runtime it reports on.</para>
|
||||
/// <para><b>Coverage is every driver that ships an <c>Inspect</c>, and that invariant is guarded</b> by
|
||||
/// <c>EquipmentTagConfigInspectorCoverageTests</c>, which reflects over the referenced
|
||||
/// <c>*.Contracts</c> assemblies — so a driver that gains an inspector cannot be silently left out. This
|
||||
|
||||
Reference in New Issue
Block a user