Builds the native 2023 R2 version-8 OpenConnection format, which (unlike v6)
carries a ConnectionType byte (Event vs Process) — required because the 2023 R2
server returns event rows only on an Event connection.
- HistorianOpen2Protocol.SerializeNativeOpenConnectionVersion8: reproduces the
302-byte v8 layout decoded from a live capture (version 8, markers, client-key
GUID, username HString, length-prefixed credential token, ClientType /
ConnectionType / flag / constant word / compact metadata / two empty strings;
the tail reuses WriteClientCommonInfo). Golden-tested
(Version8EventSerializerReproducesCapturedNativeStructure).
- HistorianNativeHandshake.BuildEventOpenConnectionVersion8Request: ConnectionType=
Event, zeroed credential token (mirroring how v6 zeros its credential block and
relies on the separate ValidateClientCredential handshake).
- HistorianGrpcHandshake.OpenSession: optional eventConnection switch; the
OpenConnection failure path now decodes the native error (type/code/ASCII).
Path A (reuse ValidateClientCredential + zeroed token) was live-tested and
DISPROVEN: the server parses the v8 buffer but rejects it at the auth check with
native 132/34 "EstablishConnection Failed to get client key" — the v8 path looks
up the client key in the registry HistoryService.ExchangeKey (ECDH) populates,
not the one ValidateClientCredential does. The event orchestrator is therefore
reverted to the v6 session (gated test still pins the no-row throw). The v8
serializer/builder are retained for Path B (implement ExchangeKey). 323/323
offline tests pass.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
Full read-only SDK (src/AVEVA.Historian.Client) implementing the CLAUDE.md required
surface against AVEVA Historian's binary WCF protocol — no native AVEVA runtime
dependency. All operations live-verified against a local Historian:
- ProbeAsync, ReadRawAsync, ReadAggregateAsync, ReadAtTimeAsync, ReadEventsAsync
- BrowseTagNamesAsync, GetTagMetadataAsync (17 native data-type codes mapped)
- GetConnectionStatusAsync, GetStoreForwardStatusAsync, GetSystemParameterAsync
- 108/108 unit + integration tests pass
Includes the reverse-engineering toolkit (tools/AVEVA.Historian.ReverseEngineering)
used to decode the protocol: WCF probes, IL inspection via dnlib, and IL-rewrite
instrumentation (instrument-wcf-{write,read}message etc.) plus the .NET Framework
trace harness (tools/AVEVA.Historian.NativeTraceHarness) for parity testing.
Sanitized handoff evidence under docs/reverse-engineering/. Native AVEVA binaries
(current/, aveva-install-x64/, aveva-install-x86/) are gitignored — fetch separately
from the AVEVA installer.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>