DelTep (extended-property delete) — wire format captured + serializer
golden-proven, but live delete is server-blocked and NOT exposed publicly:
- Captured the DelTep inBuff via a cross-session trick (harness add-tep gains
--tep-skip-add + read-for-sync before --tep-delete; Capture-DeleteTagExtended
Properties.ps1 / decode-del-tep-capture.py). Layout = same group framing as
AddTEx but property-name-only (no 0x43 value) + 0x00 group trailer.
- SerializeDeleteRequest + 4 golden tests pin the server-accepted buffer.
- A decisive experiment shows SDK-added properties ARE deletable (the native
client read-syncs and deletes one), so SDK-add is complete; the SDK's own
DelTep is rejected by CHistStorage::DeleteTagExtendedProperties even with
byte-identical inBuff, matching mode/handle, GetTgByNm+GetTepByNm prime, open
channel, and 60s retries. Root cause: the native multiplexes services over one
connection (per-connection working set); the SDK's per-service WCF channels
don't reproduce it. Kept as documented-but-blocked internal orchestrator path;
no public HistorianClient delete API.
Bounded out with evidence (no code; docs + roadmap + probe):
- R1.12 localized-property write — no op on 2020 (mirror of R1.6); no
*LocalizedPropert*/TagLocalized* symbol in any current/*.dll.
- R1.13 non-analog tag create — GATED; native AddTag rejects every non-analog
type client-side (ValidationFailed, before any WCF op): SingleByteString,
DoubleByteString, Int1 all fail, Float works. No Discrete type in the native
enum, no TagType setter. No wire request to capture.
- R1.3 timezone + R1.4 EventStorageMode — re-confirmed 2023R2/gRPC-only from
the Runtime DB schema (no timezone param, no EventStorageMode anywhere) and a
parameter-op probe (GetSystemParameter + GETRP return null/throw for every
candidate; only HistorianVersion works).
238 unit tests pass; full solution builds with 0 warnings.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
Execute HCAL roadmap R1.2 (GetRuntimeParameterAsync) end-to-end, and in doing so
discover that the "string-handle wall" blocking R1.1/R1.4/R1.5/R1.6 was a handle
FORMAT bug, not a missing native session/filter registration.
R1.2 (shipped, live-verified):
- Captured native GetRuntimeParameter -> WCF op aa/Stat/GETRP (string-handle op,
GETHI's shape), via scripts/Capture-RuntimeParam.ps1 + instrument-wcf-{write,read}message.
- HistorianRuntimeParameterProtocol serializes pRequestBuff (54 67 01 00 + uint
nameCount + per-name uint charCount + UTF-16) and parses pResponseBuff (version +
uint resultCount + CRetVariant 0x43 VT_BSTR + uint16 len + uint16 charCount + UTF-16).
- IStatusServiceContract2.GetRuntimeParameter (GETRP) op; HistorianWcfStatusClient
passes the Open2 storage-session GUID as the string handle, UPPERCASE.
- Public HistorianClient.GetRuntimeParameterAsync(name) via the dialect.
- Golden WcfRuntimeParameterProtocolTests + gated live test; returns HistorianVersion.
String-handle wall RESOLVED (proven, public APIs deferred):
- The Open2 storage GUID works as the string handle when sent UPPERCASE
(ToString("D").ToUpperInvariant()); earlier "blocked" probes used lowercase.
- Live-probed GETHI (R1.4) -> returns data; ExeC (R1.1) -> Retr.GetV prime -> ExeC ->
GetR returns a BinaryFormatter-serialized .NET DataTable. Gated
StringHandleProbeDiagnosticTests + scripts/Capture-ExecSql.ps1 + exec-sql harness scenario.
- Docs flipped: wcf-string-handle-wall.md RESOLVED banner; roadmap R1.1/R1.4 reachable,
R1.5/R1.6 likely; wcf-status-localhost.md GETRP section.
- R1.1/R1.4 public APIs NOT shipped: ExeC needs a GetR paging loop + a BinaryFormatter-
stream parser (BinaryFormatter is removed from .NET 10); GETHI full-info struct needs
its own capture.
223 unit tests pass; gated live tests green against the local 2020 Historian.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
Live-probed both against the local Historian 2020 (WCF):
- R1.3 GetServerTimeZoneAsync: Status.GetSystemTimeZoneName returns rc=0 with
an empty value under a real authenticated handle — a client-side stub in the
GetServerTime family. gRPC/2023R2-only. Reverted the implementation.
- R1.1 ExecuteSqlCommandAsync: Retrieval.ExeC returns native error type 4 /
code 51 (InvalidParameter); the contract-3 string-handle ops require an
unmapped native session/filter registration step (the StartTagQuery wall).
Adds an M1a re-classification note steering future work toward proven
uint-handle / already-wired ops (R1.4 GETHI next) over string-handle ops.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Full read-only SDK (src/AVEVA.Historian.Client) implementing the CLAUDE.md required
surface against AVEVA Historian's binary WCF protocol — no native AVEVA runtime
dependency. All operations live-verified against a local Historian:
- ProbeAsync, ReadRawAsync, ReadAggregateAsync, ReadAtTimeAsync, ReadEventsAsync
- BrowseTagNamesAsync, GetTagMetadataAsync (17 native data-type codes mapped)
- GetConnectionStatusAsync, GetStoreForwardStatusAsync, GetSystemParameterAsync
- 108/108 unit + integration tests pass
Includes the reverse-engineering toolkit (tools/AVEVA.Historian.ReverseEngineering)
used to decode the protocol: WCF probes, IL inspection via dnlib, and IL-rewrite
instrumentation (instrument-wcf-{write,read}message etc.) plus the .NET Framework
trace harness (tools/AVEVA.Historian.NativeTraceHarness) for parity testing.
Sanitized handoff evidence under docs/reverse-engineering/. Native AVEVA binaries
(current/, aveva-install-x64/, aveva-install-x86/) are gitignored — fetch separately
from the AVEVA installer.