Live-probed both against the local Historian 2020 (WCF):
- R1.3 GetServerTimeZoneAsync: Status.GetSystemTimeZoneName returns rc=0 with
an empty value under a real authenticated handle — a client-side stub in the
GetServerTime family. gRPC/2023R2-only. Reverted the implementation.
- R1.1 ExecuteSqlCommandAsync: Retrieval.ExeC returns native error type 4 /
code 51 (InvalidParameter); the contract-3 string-handle ops require an
unmapped native session/filter registration step (the StartTagQuery wall).
Adds an M1a re-classification note steering future work toward proven
uint-handle / already-wired ops (R1.4 GETHI next) over string-handle ops.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Full read-only SDK (src/AVEVA.Historian.Client) implementing the CLAUDE.md required
surface against AVEVA Historian's binary WCF protocol — no native AVEVA runtime
dependency. All operations live-verified against a local Historian:
- ProbeAsync, ReadRawAsync, ReadAggregateAsync, ReadAtTimeAsync, ReadEventsAsync
- BrowseTagNamesAsync, GetTagMetadataAsync (17 native data-type codes mapped)
- GetConnectionStatusAsync, GetStoreForwardStatusAsync, GetSystemParameterAsync
- 108/108 unit + integration tests pass
Includes the reverse-engineering toolkit (tools/AVEVA.Historian.ReverseEngineering)
used to decode the protocol: WCF probes, IL inspection via dnlib, and IL-rewrite
instrumentation (instrument-wcf-{write,read}message etc.) plus the .NET Framework
trace harness (tools/AVEVA.Historian.NativeTraceHarness) for parity testing.
Sanitized handoff evidence under docs/reverse-engineering/. Native AVEVA binaries
(current/, aveva-install-x64/, aveva-install-x86/) are gitignored — fetch separately
from the AVEVA installer.