Commit Graph

7 Commits

Author SHA1 Message Date
Joseph Doherty 108220c36b R1.5 GetTagExtendedPropertiesAsync (GetTepByNm) + R1.6 closed (no op)
Ship tag extended-property reads over the 2020 WCF aa/Retr/GetTepByNm op:
HistorianClient.GetTagExtendedPropertiesAsync(tag) -> name/value pairs.

String-handle op reached with the Open2 storage-session GUID formatted
uppercase (same format that unlocked GETRP/GETHI/ExeC). Routed via the
name-based native path (GetTagExtendedPropertiesByName, server-fetch flag),
not the index-based TagQuery path.

Evidence-backed findings from the capture:
- GetTepByNm (and GetTgByNm) succeed with the uppercase handle -- further
  validates the resolved string-handle wall.
- QTB (StartTagQuery) does NOT punch through: captured uppercase, it still
  fails server-side (CMdServer::StartActiveTagnamesQuery over the
  aahMetadataServer pipe) -- a metadata-server blocker, not handle format.
- R1.6 (localized properties) has NO distinct op (only error-message/UI-text
  localization in the managed client); collapses into R1.5. Closed, not throwing.

Wire format (golden-pinned, synthetic bytes -- no dev tag names committed):
- request tagNames = uint count + per-name(uint charCount + UTF-16)
- response = uint tagCount + per-tag(marker + compact-ASCII name +
  uint propCount + per-prop(marker + compact-ASCII name + 0x43 VT_BSTR value)
  + trailer); sequence-paged.

Adds: HistorianTagExtendedProperty model, HistorianTagExtendedPropertyProtocol
(codec), HistorianWcfTagExtendedPropertyClient (orchestration), dialect +
public API; golden WcfTagExtendedPropertyProtocolTests (4) + gated live test
(HISTORIAN_TEP_TAG). Tooling: Capture-TagExtendedProperties.ps1,
decode-tag-properties-capture.py, harness tag-extended-properties scenario.
Docs: wcf-tag-extended-properties.md; roadmap R1.5 DONE / R1.6 collapsed;
wall doc + memory updated with the QTB-server-side nuance. 228 tests green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
2026-06-20 22:52:07 -04:00
Joseph Doherty 4da5287d01 R1.2 GetRuntimeParameter + string-handle wall RESOLVED (handle-format bug)
Execute HCAL roadmap R1.2 (GetRuntimeParameterAsync) end-to-end, and in doing so
discover that the "string-handle wall" blocking R1.1/R1.4/R1.5/R1.6 was a handle
FORMAT bug, not a missing native session/filter registration.

R1.2 (shipped, live-verified):
- Captured native GetRuntimeParameter -> WCF op aa/Stat/GETRP (string-handle op,
  GETHI's shape), via scripts/Capture-RuntimeParam.ps1 + instrument-wcf-{write,read}message.
- HistorianRuntimeParameterProtocol serializes pRequestBuff (54 67 01 00 + uint
  nameCount + per-name uint charCount + UTF-16) and parses pResponseBuff (version +
  uint resultCount + CRetVariant 0x43 VT_BSTR + uint16 len + uint16 charCount + UTF-16).
- IStatusServiceContract2.GetRuntimeParameter (GETRP) op; HistorianWcfStatusClient
  passes the Open2 storage-session GUID as the string handle, UPPERCASE.
- Public HistorianClient.GetRuntimeParameterAsync(name) via the dialect.
- Golden WcfRuntimeParameterProtocolTests + gated live test; returns HistorianVersion.

String-handle wall RESOLVED (proven, public APIs deferred):
- The Open2 storage GUID works as the string handle when sent UPPERCASE
  (ToString("D").ToUpperInvariant()); earlier "blocked" probes used lowercase.
- Live-probed GETHI (R1.4) -> returns data; ExeC (R1.1) -> Retr.GetV prime -> ExeC ->
  GetR returns a BinaryFormatter-serialized .NET DataTable. Gated
  StringHandleProbeDiagnosticTests + scripts/Capture-ExecSql.ps1 + exec-sql harness scenario.
- Docs flipped: wcf-string-handle-wall.md RESOLVED banner; roadmap R1.1/R1.4 reachable,
  R1.5/R1.6 likely; wcf-status-localhost.md GETRP section.
- R1.1/R1.4 public APIs NOT shipped: ExeC needs a GetR paging loop + a BinaryFormatter-
  stream parser (BinaryFormatter is removed from .NET 10); GETHI full-info struct needs
  its own capture.

223 unit tests pass; gated live tests green against the local 2020 Historian.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
2026-06-20 22:10:31 -04:00
Joseph Doherty 6d470eab4a R1.7: server-side event filters — ReadEventsAsync(HistorianEventFilter), live-honored
Roadmap M1 R1.7. Filters are set on the native EventQuery object via
AddEventFilter(property, HistorianComparisionType, value) — NOT EventQueryArgs
(time/count/order only). Found via a new harness --dump-type-members command.

Captured the native filtered StartEventQuery pRequestBuff (Capture-EventFilter.ps1 +
harness --event-filter knob) and diffed Equal(0) vs Contains(12) to isolate the
operator field. Filter block (decoded byte-for-byte):
  ushort 0 + uint filterCount + uint condCount + uint nameLen + name(UTF-16) +
  uint 1 + ushort op + uint 1 + value(0x09-LEN-0x00 compact-ASCII) + byte 0

The filter is REAL, not inert (unlike the analog-summary knobs): a non-matching
predicate returns 0 events; Type=Equal=User.Write returns only User.Write events.
Verified live via both the native harness and the SDK.

- HistorianClient.ReadEventsAsync(start, end, HistorianEventFilter, ct) overload
- HistorianEventFilter + HistorianEventComparison (18 ops, ordinals = native)
- Filter encoding in HistorianEventQueryProtocol (empty-filter path unchanged)
- Golden-byte tests (block match, op field, empty-filter regression) + gated live test

Single string-valued predicate only; multi-filter (OR) / multi-condition (AND via
AddEventFilterCondition) framing is partially captured and not shipped. 216 unit
tests pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
2026-06-20 18:32:03 -04:00
Joseph Doherty f1e23a3a02 M2: implement SendEventAsync — event-send rides WCF AddS2, not the storage pipe
Roadmap Milestone 2 (event sending). Capture disproved the assumption that event
delivery uses the non-WCF storage-engine pipe (which would block it like revision
writes): a native AddStreamedValue(HistorianEvent) leaves over WCF as AddS2
(IHistoryServiceContract2.AddStreamValues2). CM_EVENT is a built-in registered tag,
so the 129 TagNotFoundInCache gate that blocks AddS2 for user tags does not apply.

- R2.1: NativeTraceHarness "event-send" scenario + Capture-EventSend.ps1; two
  captures diffed to separate constant framing from value-dependent fields.
- R2.2: HistorianEventWriteProtocol serializes the AddS2 pBuf (storage sample buffer
  wrapping the event VTQ) — golden-byte tested. Decoded "OS" sig + length fields +
  CM_EVENT tag id + EventTime/ReceivedTime FILETIMEs + Opc 192 + 0x118D descriptor +
  event Id + Namespace + EventType + version 5 + typed property bag.
- R2.3/R2.4: HistorianWcfEventOrchestrator.SendEventAsync (Open2 event-mode 0x501 ->
  reuse CM_EVENT RTag2/EnsT2 -> AddStreamValues2) + HistorianClient.SendEventAsync.
- R2.5: gated live test; server accepts the AddS2 (success, empty error buffer).

Server requires delivered byte[].Length == declared packet length (uint32@0x04); the
native relies on the MDAS encoder adding a pad byte, so the SDK emits an explicit
trailing 0x00 (else AddS2 rejects with "CValuStream buffer size vs packet length
mismatch"). Original events only (RevisionVersion=0) with string properties; other
property types + revision/update/delete throw ProtocolEvidenceMissingException.

Caveat (documented): accepted events are not persisted on the local dev box; the
native client behaves identically (event ingestion pipeline inactive) — not an SDK
gap. 212 unit tests pass; 16/16 event tests pass live.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01B6mcaT2PjRFKcogzp9UkfC
2026-06-20 18:00:52 -04:00
Joseph Doherty b8280a1465 Drop SupportedOSPlatform gates; SDK now runs on Linux
The dialect / orchestrators were defensively gated on Windows because
HistorianSspiClient previously P/Invoked InitializeSecurityContextW. With
that replaced by NegotiateAuthentication (cross-platform), the gates are
unnecessary. Removed them from:

- Historian2020ProtocolDialect (4 read paths + 3 status helpers)
- HistorianClient.EnsureTagAsync / DeleteTagAsync
- HistorianWcf{Auth,Read,Event,Status,TagWrite}Orchestrator/Helper
- HistorianWcf{HistAddressing,MessageCapture}Behavior
- HistorianWcfBindingFactory (with #pragma on the Named-Pipe builder
  which still requires Windows at the BCL level)

Runtime constraint: LocalPipe and RemoteTcpIntegrated transports still
require Windows because NetNamedPipeBinding and the Windows transport
security binding are Windows-only at the BCL level. RemoteTcpCertificate
is now usable from Linux, and ProbeAsync is verified working from a
Debian client (10.100.0.35) against the Windows Historian (10.100.0.48).

171/171 tests still pass on Windows.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 22:27:57 -04:00
dohertj2 cfc8d44e3a Implement EnsureTagAsync (live-verified) + DeleteTagAsync (DelT semantics partial)
New SDK surface:
  HistorianClient.EnsureTagAsync(HistorianTagDefinition)
  HistorianClient.DeleteTagAsync(string tagName)

Plumbing:
  src/AVEVA.Historian.Client/Models/HistorianTagDefinition.cs
    Public input model — TagName/Description/EngineeringUnit/DataType/MinEU/MaxEU.
    Currently only HistorianDataType.Float is live-verified.

  src/AVEVA.Historian.Client/Wcf/HistorianTagWriteProtocol.cs
    SerializeAnalogCTagMetadata produces 146-byte payload byte-for-byte
    identical to the captured native EnsT2(Float) request.
    SerializeDeleteTagNames produces ushort 0x6751 + ushort 1 + uint count
    + per-tag (uint charCount + UTF-16 chars).

  src/AVEVA.Historian.Client/Wcf/HistorianWcfTagWriteOrchestrator.cs
    Both EnsT2 and DelT run the full Stat-priming chain captured for the
    analog flow (UpdC3 + Stat.GetV ×3 + Stat.GETHI ×2 + 7× GetSystemParameter
    + Trx.GetV + Retr.GetV).

  src/AVEVA.Historian.Client/Wcf/HistorianWcfTagClient.cs
    MapDataType extended to accept tag-origin marker 0xC7 (SDK-created tags).

Tests:
  5 golden-byte tests (HistorianTagWriteProtocolTests):
    SerializeAnalogCTagMetadata byte-for-byte match against captured 146-byte fixture
    SerializeAnalogCTagMetadata produces different bytes for different inputs
    SerializeDeleteTagNames single-tag matches captured shape
    SerializeDeleteTagNames multi-tag appends each
    SerializeDeleteTagNames empty list throws

  1 live integration test (gated by HISTORIAN_WRITE_SANDBOX_TAG):
    EnsureTagAsync_AndDeleteTagAsync_RoundTrip_AgainstLocalHistorian
    EnsureTagAsync creates the sandbox tag, GetTagMetadataAsync reads it
    back. 130/130 tests pass.

Harness improvements:
  --write-delete-after now runs DelT independently of AddStreamedValue
  outcome.
  HistorianTagStatusList constructed correctly for DeleteTags reflection
  call (previous StringCollection attempt failed with TypeMismatch).

Known DelT gap: SDK's DeleteTagAsync returns true but server-side
cascading deletion does not always complete (the row remains in
Runtime.dbo.Tag). The captured native flow's DelT removes the tag
cleanly (verified via harness --write-delete-after), so something
around the WCF DelT call is missing from our orchestrator. Documented
as known issue with SMC-based cleanup as workaround.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 08:33:21 -04:00
dohertj2 c95824a65d Initial commit: managed .NET 10 AVEVA Historian SDK + reverse-engineering toolkit
Full read-only SDK (src/AVEVA.Historian.Client) implementing the CLAUDE.md required
surface against AVEVA Historian's binary WCF protocol — no native AVEVA runtime
dependency. All operations live-verified against a local Historian:

- ProbeAsync, ReadRawAsync, ReadAggregateAsync, ReadAtTimeAsync, ReadEventsAsync
- BrowseTagNamesAsync, GetTagMetadataAsync (17 native data-type codes mapped)
- GetConnectionStatusAsync, GetStoreForwardStatusAsync, GetSystemParameterAsync
- 108/108 unit + integration tests pass

Includes the reverse-engineering toolkit (tools/AVEVA.Historian.ReverseEngineering)
used to decode the protocol: WCF probes, IL inspection via dnlib, and IL-rewrite
instrumentation (instrument-wcf-{write,read}message etc.) plus the .NET Framework
trace harness (tools/AVEVA.Historian.NativeTraceHarness) for parity testing.

Sanitized handoff evidence under docs/reverse-engineering/. Native AVEVA binaries
(current/, aveva-install-x64/, aveva-install-x86/) are gitignored — fetch separately
from the AVEVA installer.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 06:31:48 -04:00