2 Commits

Author SHA1 Message Date
Joseph Doherty 7e4d713eb3 Cross-platform NegotiateAuthentication; StorageType field; docs polish
HistorianSspiClient rewritten on top of System.Net.Security.NegotiateAuthentication
in place of P/Invoke into secur32.dll's InitializeSecurityContextW. The class
keeps the same Next() / Dispose() / two-constructor surface so callers don't
change. RequiredProtectionLevel=EncryptAndSign + AllowedImpersonationLevel=
Identification produces a request-flag set equivalent to the captured native
0x2081C / 0x81C bitmasks (still preserved as constants for the existing unit
tests). Removes the only Windows P/Invoke in the production SDK; the
[SupportedOSPlatform("windows")] gating elsewhere stays in place pending a
separate sweep.

HistorianStorageType (Cyclic = 1, Delta = 2):
Captured 2026-05-04 via --write-storage-type on the harness. Delta differs
from Cyclic in three places — header byte 10 (0x02 -> 0x06), flag-block
byte 1 (0x01 -> 0x02), and 4 zero bytes inserted after StorageRate before
the FILETIME. Server persists Tag.StorageType=1/2 accordingly. Plumbed
through HistorianTagDefinition.StorageType + serializer + orchestrator + 2
new tests (golden bytes + live SQL persistence verification).

Docs polish:
CLAUDE.md no longer claims "no P/Invoke" (HistorianSspiClient is the one
allowed P/Invoke surface); updated test count to 169+; AGENTS.md Required
SDK Surface and Repository Layout brought up to date with the live state
including the write surface; handoff.md "not a git working tree" obsolete
note removed.

171/171 tests pass with the NegotiateAuthentication replacement (was 169;
+2 new tests for StorageType).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 22:19:37 -04:00
dohertj2 c95824a65d Initial commit: managed .NET 10 AVEVA Historian SDK + reverse-engineering toolkit
Full read-only SDK (src/AVEVA.Historian.Client) implementing the CLAUDE.md required
surface against AVEVA Historian's binary WCF protocol — no native AVEVA runtime
dependency. All operations live-verified against a local Historian:

- ProbeAsync, ReadRawAsync, ReadAggregateAsync, ReadAtTimeAsync, ReadEventsAsync
- BrowseTagNamesAsync, GetTagMetadataAsync (17 native data-type codes mapped)
- GetConnectionStatusAsync, GetStoreForwardStatusAsync, GetSystemParameterAsync
- 108/108 unit + integration tests pass

Includes the reverse-engineering toolkit (tools/AVEVA.Historian.ReverseEngineering)
used to decode the protocol: WCF probes, IL inspection via dnlib, and IL-rewrite
instrumentation (instrument-wcf-{write,read}message etc.) plus the .NET Framework
trace harness (tools/AVEVA.Historian.NativeTraceHarness) for parity testing.

Sanitized handoff evidence under docs/reverse-engineering/. Native AVEVA binaries
(current/, aveva-install-x64/, aveva-install-x86/) are gitignored — fetch separately
from the AVEVA installer.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 06:31:48 -04:00