Joseph Doherty e9e44a9ef0 test(loadharness)+docs: wire-path stream probes — R2 batching benchmark-proven at target scale
The WP-4 runs measured the stream path only up to the bounded send channel;
the probe deliberately substituted the socket hop with a controllable reader,
which is exactly where the R2 SiteStreamEventBatcher lives — so batching had
never been in any benchmark's hot path. The harness now also attaches per-site
wire probes: a real Kestrel h2c listener hosting the production
SiteStreamGrpcServer, dialed by the production SiteStreamGrpcClient with
batching negotiated, batch sizes read from the production batch_size histogram
via a MeterListener (--wire-probes-per-site, default 10; 0 restores the old
shape). Full-scale run (10x500x75, 20-min window, results doc §8 + raw JSON):
899,807 events in 12,462 frames (mean 72.2 ev/frame, p50=p99=75), wire P99
43.4 ms vs the 250 ms budget — every batch pays the full 25 ms linger since a
75-event burst never hits the 100 cap — zero drops, zero faults, offered load
100.0% of nominal with fan-out doubled. CI smoke Fact now asserts the wire
path carries traffic and observes frames.
2026-08-18 10:32:46 -04:00
..