fc48db480c
One scoped read that answers "is anything waiting to be deployed?" for the whole fleet: each site's stored artifact revision hash compared against what a deploy would send right now (NeverDeployed / Current / OutOfDate), plus per-site deployed/stale/unknown instance tallies from the batched staleness evaluation. NeverDeployed is deliberately NOT a pending update — the operator has not deployed yet — and exceptions propagate so the caller's single-flight cache can render "unavailable" rather than invent an "up to date". Adds the validated PendingUpdatesCacheTtl (60 s) that TTL will key off. Claude-Session: https://claude.ai/code/session_01Y5ef34iUUMjmwnMpL9xgmB
58 lines
3.6 KiB
C#
58 lines
3.6 KiB
C#
using ZB.MOM.WW.Configuration;
|
|
|
|
namespace ZB.MOM.WW.ScadaBridge.DeploymentManager;
|
|
|
|
/// <summary>
|
|
/// Validates <see cref="DeploymentManagerOptions"/> at startup. Each timeout is
|
|
/// applied as a linked-CTS deadline around a lifecycle command, per-site artifact
|
|
/// deployment, or operation-lock acquisition; a zero/negative value makes the
|
|
/// deadline fire immediately (or the <see cref="System.Threading.CancellationTokenSource"/>
|
|
/// constructor throw), breaking deployments with an opaque failure. Registered
|
|
/// with <c>ValidateOnStart()</c> so a bad <c>ScadaBridge:DeploymentManager</c>
|
|
/// section fails fast at boot with a clear, key-naming message.
|
|
/// </summary>
|
|
public sealed class DeploymentManagerOptionsValidator : OptionsValidatorBase<DeploymentManagerOptions>
|
|
{
|
|
/// <inheritdoc />
|
|
protected override void Validate(ValidationBuilder builder, DeploymentManagerOptions options)
|
|
{
|
|
builder.RequireThat(options.LifecycleCommandTimeout > TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:LifecycleCommandTimeout must be a positive duration " +
|
|
$"(was {options.LifecycleCommandTimeout}); it bounds a lifecycle command round-trip.");
|
|
|
|
builder.RequireThat(options.ArtifactDeploymentTimeoutPerSite > TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:ArtifactDeploymentTimeoutPerSite must be a positive duration " +
|
|
$"(was {options.ArtifactDeploymentTimeoutPerSite}); it bounds per-site artifact deployment.");
|
|
|
|
builder.RequireThat(options.OperationLockTimeout > TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:OperationLockTimeout must be a positive duration " +
|
|
$"(was {options.OperationLockTimeout}); it bounds acquiring an instance operation lock.");
|
|
|
|
builder.RequireThat(options.SiteDeploymentMaxParallelism > 0,
|
|
$"ScadaBridge:DeploymentManager:SiteDeploymentMaxParallelism must be at least 1 " +
|
|
$"(was {options.SiteDeploymentMaxParallelism}); it is the SemaphoreSlim bound on a bulk " +
|
|
$"site deployment's site round-trips, and a non-positive value would deadlock the fan-out.");
|
|
|
|
builder.RequireThat(options.SiteDeploymentTimeoutPerInstance > TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:SiteDeploymentTimeoutPerInstance must be a positive duration " +
|
|
$"(was {options.SiteDeploymentTimeoutPerInstance}); it bounds each instance's site round-trip " +
|
|
$"inside a bulk site deployment.");
|
|
|
|
builder.RequireThat(options.SiteDeploymentReconcileTimeout > TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:SiteDeploymentReconcileTimeout must be a positive duration " +
|
|
$"(was {options.SiteDeploymentReconcileTimeout}); it bounds each query-before-redeploy " +
|
|
$"reconciliation inside a bulk site deployment's serial prepare phase.");
|
|
|
|
builder.RequireThat(options.PendingUpdatesCacheTtl > TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:PendingUpdatesCacheTtl must be a positive duration " +
|
|
$"(was {options.PendingUpdatesCacheTtl}); it is the freshness window of the Central UI " +
|
|
$"pending-updates snapshot, and a non-positive value would re-flatten the whole fleet on " +
|
|
$"every poll of every open circuit.");
|
|
|
|
builder.RequireThat(options.TerminalDeploymentRecordRetention >= TimeSpan.Zero,
|
|
$"ScadaBridge:DeploymentManager:TerminalDeploymentRecordRetention must not be negative " +
|
|
$"(was {options.TerminalDeploymentRecordRetention}); use TimeSpan.Zero to disable purging of " +
|
|
$"terminal deployment records.");
|
|
}
|
|
}
|