Files
ScadaBridge/tests/ZB.MOM.WW.ScadaBridge.LoadHarness/Metrics/BatchSizeAggregator.cs
T
Joseph Doherty e9e44a9ef0 test(loadharness)+docs: wire-path stream probes — R2 batching benchmark-proven at target scale
The WP-4 runs measured the stream path only up to the bounded send channel;
the probe deliberately substituted the socket hop with a controllable reader,
which is exactly where the R2 SiteStreamEventBatcher lives — so batching had
never been in any benchmark's hot path. The harness now also attaches per-site
wire probes: a real Kestrel h2c listener hosting the production
SiteStreamGrpcServer, dialed by the production SiteStreamGrpcClient with
batching negotiated, batch sizes read from the production batch_size histogram
via a MeterListener (--wire-probes-per-site, default 10; 0 restores the old
shape). Full-scale run (10x500x75, 20-min window, results doc §8 + raw JSON):
899,807 events in 12,462 frames (mean 72.2 ev/frame, p50=p99=75), wire P99
43.4 ms vs the 250 ms budget — every batch pays the full 25 ms linger since a
75-event burst never hits the 100 cap — zero drops, zero faults, offered load
100.0% of nominal with fan-out doubled. CI smoke Fact now asserts the wire
path carries traffic and observes frames.
2026-08-18 10:32:46 -04:00

137 lines
5.0 KiB
C#

using System.Diagnostics.Metrics;
using ZB.MOM.WW.ScadaBridge.Commons.Observability;
namespace ZB.MOM.WW.ScadaBridge.LoadHarness.Metrics;
/// <summary>
/// Captures the production <c>scadabridge.site.stream.batch_size</c> histogram via a
/// <see cref="MeterListener"/>, so a wire-path run can report the actual frame/batch
/// distribution the R2 batcher produced — not a client-side reconstruction. The
/// instrument is recorded once per emitted gRPC frame (negotiated streams only), with
/// the frame's event count as the value, which makes <c>count = frames</c> and
/// <c>sum = events</c> exactly.
///
/// <para>
/// The harness hosts every site's <see cref="ZB.MOM.WW.ScadaBridge.Communication.Grpc.SiteStreamGrpcServer"/>
/// in-process, so this listener sees every wire frame the run emits and nothing else —
/// no other component in the harness records this instrument.
/// </para>
/// </summary>
public sealed class BatchSizeAggregator : IDisposable
{
/// <summary>
/// Sizes above this are clamped into the last bucket. The production cap is
/// <c>GrpcStreamBatchMaxEvents</c> = 100, so 512 leaves generous headroom for a
/// configured-up run without an unbounded array.
/// </summary>
public const int MaxTrackedBatchSize = 512;
private readonly MeterListener _listener;
private readonly long[] _framesBySize = new long[MaxTrackedBatchSize + 1];
/// <summary>Starts listening. Must be created BEFORE the first stream opens.</summary>
public BatchSizeAggregator()
{
_listener = new MeterListener
{
InstrumentPublished = (instrument, listener) =>
{
if (instrument.Meter.Name == ScadaBridgeTelemetry.MeterName &&
instrument.Name == "scadabridge.site.stream.batch_size")
{
listener.EnableMeasurementEvents(instrument);
}
},
};
_listener.SetMeasurementEventCallback<int>((_, value, _, _) =>
{
var size = Math.Clamp(value, 1, MaxTrackedBatchSize);
Interlocked.Increment(ref _framesBySize[size]);
});
_listener.Start();
}
/// <summary>Copies the cumulative per-size frame counts.</summary>
/// <returns>Index = events-per-frame (clamped), value = frames emitted at that size.</returns>
public long[] Snapshot()
{
var copy = new long[_framesBySize.Length];
for (var i = 0; i < copy.Length; i++)
copy[i] = Interlocked.Read(ref _framesBySize[i]);
return copy;
}
/// <inheritdoc />
public void Dispose() => _listener.Dispose();
}
/// <summary>
/// Batch-size distribution over one measurement window, computed from two
/// <see cref="BatchSizeAggregator.Snapshot"/>s. Percentiles are exact (integer sizes,
/// full counts — nothing is bucketed away).
/// </summary>
/// <param name="Frames">gRPC frames written in the window.</param>
/// <param name="Events">Events those frames carried.</param>
/// <param name="BatchedFrames">Frames that carried more than one event.</param>
/// <param name="MeanEventsPerFrame">Events / Frames.</param>
/// <param name="P50">Median events-per-frame.</param>
/// <param name="P95">95th percentile events-per-frame.</param>
/// <param name="P99">99th percentile events-per-frame.</param>
/// <param name="Max">Largest frame observed in the window.</param>
public sealed record BatchSizeWindow(
long Frames,
long Events,
long BatchedFrames,
double MeanEventsPerFrame,
int P50,
int P95,
int P99,
int Max)
{
/// <summary>Computes the window distribution from cumulative start/end snapshots.</summary>
/// <param name="start">Snapshot at window start.</param>
/// <param name="end">Snapshot at window end.</param>
/// <returns>The distribution of frames emitted between the two snapshots.</returns>
public static BatchSizeWindow From(long[] start, long[] end)
{
long frames = 0, events = 0, batched = 0;
var max = 0;
var delta = new long[end.Length];
for (var size = 1; size < end.Length; size++)
{
var n = end[size] - start[size];
if (n <= 0) continue;
delta[size] = n;
frames += n;
events += n * size;
if (size > 1) batched += n;
max = size;
}
return new BatchSizeWindow(
frames, events, batched,
frames == 0 ? 0 : events / (double)frames,
Percentile(delta, frames, 50),
Percentile(delta, frames, 95),
Percentile(delta, frames, 99),
max);
}
private static int Percentile(long[] delta, long frames, double percentile)
{
if (frames == 0) return 0;
var target = (long)Math.Ceiling(frames * percentile / 100.0);
if (target < 1) target = 1;
long cumulative = 0;
for (var size = 1; size < delta.Length; size++)
{
cumulative += delta[size];
if (cumulative >= target)
return size;
}
return delta.Length - 1;
}
}