<Project Sdk="Microsoft.NET.Sdk.Razor">
|
|
|
|
<PropertyGroup>
|
|
<TargetFramework>net10.0</TargetFramework>
|
|
<ImplicitUsings>enable</ImplicitUsings>
|
|
<Nullable>enable</Nullable>
|
|
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
|
</PropertyGroup>
|
|
|
|
<ItemGroup>
|
|
<FrameworkReference Include="Microsoft.AspNetCore.App" />
|
|
</ItemGroup>
|
|
|
|
<ItemGroup>
|
|
<InternalsVisibleTo Include="ZB.MOM.WW.ScadaBridge.CentralUI.Tests" />
|
|
</ItemGroup>
|
|
|
|
<ItemGroup>
|
|
<PackageReference Include="Microsoft.CodeAnalysis.CSharp.Scripting" />
|
|
<PackageReference Include="Microsoft.CodeAnalysis.CSharp.Workspaces" />
|
|
<PackageReference Include="ZB.MOM.WW.Theme" />
|
|
<PackageReference Include="ZB.MOM.WW.Secrets.Ui" />
|
|
</ItemGroup>
|
|
|
|
<ItemGroup>
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.Commons/ZB.MOM.WW.ScadaBridge.Commons.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.ScriptAnalysis/ZB.MOM.WW.ScadaBridge.ScriptAnalysis.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.Security/ZB.MOM.WW.ScadaBridge.Security.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.TemplateEngine/ZB.MOM.WW.ScadaBridge.TemplateEngine.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.DeploymentManager/ZB.MOM.WW.ScadaBridge.DeploymentManager.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.HealthMonitoring/ZB.MOM.WW.ScadaBridge.HealthMonitoring.csproj" />
|
|
<!-- SMS Notifications: the NotificationListForm Type selector derives its options
|
|
from the registered INotificationDeliveryAdapter set (via INotificationChannelCatalog)
|
|
so it reflects the channels the central node can actually deliver — never a hardcoded
|
|
{Email, Sms}. The adapters live in NotificationOutbox; no NuGet packages added. -->
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.NotificationOutbox/ZB.MOM.WW.ScadaBridge.NotificationOutbox.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.KpiHistory/ZB.MOM.WW.ScadaBridge.KpiHistory.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.Communication/ZB.MOM.WW.ScadaBridge.Communication.csproj" />
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.Transport/ZB.MOM.WW.ScadaBridge.Transport.csproj" />
|
|
<!-- Secured Writes (M7): the SecuredWriteService dispatches the secured-write
|
|
management commands to the central ManagementActor via the in-process
|
|
ManagementActorHolder seam (the same Ask path the HTTP /management endpoint uses). -->
|
|
<ProjectReference Include="../ZB.MOM.WW.ScadaBridge.ManagementService/ZB.MOM.WW.ScadaBridge.ManagementService.csproj" />
|
|
</ItemGroup>
|
|
|
|
</Project>
|