- BrowseOpcUaNodeCommand: int DataConnectionId -> string ConnectionName (site DataConnectionManagerActor indexes children by name; CentralUI already has the connection name in scope via the dropdown — no extra plumbing across the trust boundary). - IOpcUaBrowseService / OpcUaBrowseService: parameter renamed accordingly. - OpcUaBrowserDialog: collapse the duplicate ConnectionName parameters (display label and routing key are the same string). - Task 10: DataConnectionManagerActor forwards BrowseOpcUaNodeCommand to its child by name (owns ConnectionNotFound); DataConnectionActor adds the receive across all three lifecycle states (Connecting / Connected / Reconnecting) and maps adapter outcomes to BrowseFailureKind (NotBrowsable / ConnectionNotConnected / Timeout / ServerError). - Task 17: SetFailure in OpcUaBrowserDialog implements the full BrowseFailureKind switch with friendly UI messages. - Tests: DataConnectionManagerBrowseHandlerTests covers ConnectionNotFound, NotBrowsable, success, and ConnectionNotConnectedException paths.