Files
ScadaBridge/docs
Joseph Doherty caf14a3e03 feat(ui): admin manual-failover control on the health page
CentralFailoverControl lives in Components/Health/ (matching AuditKpiTiles /
SiteCallKpiTiles) rather than inline in Health.razor, so it is testable without
standing up the whole dashboard's DI graph.

- Admin-gated via AuthorizeView + RequireAdmin. The Health page itself is
  intentionally all-roles, so the gate belongs on the control, not the page.
- Disabled with an explanatory title when the pair has no online standby;
  the authoritative guard remains server-side against live cluster membership.
- Confirmation dialog (IDialogService, the page idiom) warns that singletons
  hand over, in-flight work on the active node is interrupted, and THIS PAGE
  will disconnect and reconnect against the new active node -- Traefik routes
  the UI to the node being restarted, so a working failover otherwise reads as
  a crash the admin caused.
- A refused failover (service returns null) surfaces the refusal; the UI never
  reports a failover that did not happen.

7 bUnit tests. Two harness requirements that bit first: AuthorizeView needs a
cascading AuthenticationState (the app supplies it from the layout), and
BunitContext pre-registers a placeholder IAuthorizationService that throws on
policy evaluation -- both handled the same way NavMenuTests documents.

Runbook paragraphs added to Component-ClusterInfrastructure.md (new Manual
Failover section) and docker/README.md.
2026-07-22 07:00:10 -04:00
..