QA Warm gate (lmxopcua#907, 2026-11-13): a graceful stop of the Warm Primary reported ServiceLevel 0 for ~6 s - shorter than the 10 s degraded window - the next unreadable sample cleared the streak, and the connection retried the stopped node FailoverRetryCount times: Good on the peer after 66 s, peer Active in 0.2 s. Two going-away triggers on top of #138, both still requiring a Healthy (>= 200), higher level on the other endpoint and honouring the minimum dwell: - ServiceLevel 0 (Part 4 Maintenance) probes the other endpoint at once instead of waiting out the window - once per degraded streak, so a non-Healthy peer is re-probed once per window, not every poll. Other Degraded levels (standby 90/50, booting 1) still wait the window. - A lost link whose session's last KNOWN ServiceLevel was < 200 (unreadable samples don't overwrite it) probes the other endpoint before the first reconnect attempt, holding the reconnect timer. Healthy -> switch and reconnect at zero delay, the stopped node is never retried; otherwise the ordinary retry cycle runs (less the probe's time). After only Healthy levels (250/240, Unset), inside the dwell, or with the feature off: unchanged retry-then-failover. Tests: DataConnectionGoingAwayFailoverTests (10 cases, each trigger and non-trigger with positive controls, connect-order artifact assertions) and a real in-process OPC UA server pair graceful-stop e2e on production defaults: 1.1 s (lost-link trigger alone 12.1 s, neither 33.1 s -> fails the 10 s bound). 13 mutants, all killed. DCL tests 608/608 (3 full runs); solution 0 warnings. Docs: Component-DataConnectionLayer, components/DataConnectionLayer. Not deployed; QA live re-check pending. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
451 lines
22 KiB
C#
451 lines
22 KiB
C#
using System.Globalization;
|
|
using Akka.Actor;
|
|
using Akka.Event;
|
|
using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol;
|
|
using ZB.MOM.WW.ScadaBridge.Commons.Serialization;
|
|
using ZB.MOM.WW.ScadaBridge.Commons.Types.DataConnections;
|
|
|
|
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Actors;
|
|
|
|
/// <summary>
|
|
/// ScadaBridge#138 — ServiceLevel-aware failover between a primary and a backup endpoint.
|
|
///
|
|
/// <para>
|
|
/// <b>Why.</b> Until now the connection failed over only when the link itself misbehaved
|
|
/// (<c>FailoverRetryCount</c> consecutive connect failures or unstable disconnects). Under OtOpcUa
|
|
/// Warm redundancy (lmxopcua#717) the standby keeps a perfectly healthy session but serves
|
|
/// <c>BadOutOfService</c> data at a standby ServiceLevel (90 healthy / 50 degraded / 1 booting), so a
|
|
/// connection that lands there would sit on Bad quality indefinitely.
|
|
/// </para>
|
|
///
|
|
/// <para>
|
|
/// <b>What.</b> While Connected, the connected endpoint's <c>Server_ServiceLevel</c> is polled every
|
|
/// <see cref="DataConnectionOptions.ServiceLevelPollInterval"/>. A level below
|
|
/// <see cref="HealthyServiceLevelMinimum"/> (200, the bottom of the Part 4 Healthy band) starts a
|
|
/// degraded streak; any Healthy or unreadable sample ends it. Once the streak has lasted the
|
|
/// connection's degraded window — or immediately on the first sample after a (re)connect, which is
|
|
/// the "prefer the better endpoint on connect" rule — the other endpoint is probed with a
|
|
/// short-lived session. The connection switches only when that probe reads a Healthy level that is
|
|
/// also higher than the connected one, and never within the dwell time of the previous
|
|
/// ServiceLevel switch. Otherwise it stays put and the window re-arms.
|
|
/// </para>
|
|
///
|
|
/// <para>
|
|
/// <b>Unchanged behaviour.</b> A level of 200 or more never starts a streak, so today's OtOpcUa pair
|
|
/// (250 Primary / 240 Secondary) never triggers anything; an adapter without
|
|
/// <see cref="IServiceLevelReadable"/> (MxGateway) and a connection without a backup are never
|
|
/// monitored at all. The switch itself reuses <see cref="SwitchToOtherEndpoint"/> and the reconnect
|
|
/// cycle, exactly like the connection-driven failovers.
|
|
/// </para>
|
|
///
|
|
/// <para>
|
|
/// <b>A server going away (ScadaBridge#141).</b> A graceful stop of a redundant OtOpcUa node reports
|
|
/// ServiceLevel 0 for only a few seconds before the session closes — shorter than the degraded window
|
|
/// — and the following unreadable sample cleared the streak, so the connection fell back to the
|
|
/// connectivity path and retried the stopped node <c>FailoverRetryCount</c> times (66 s on QA). Two
|
|
/// going-away triggers now skip that wait: (1) a sample of <see cref="MaintenanceServiceLevel"/> (0,
|
|
/// Part 4 "Maintenance": the server is not available for use) probes the other endpoint at once,
|
|
/// without the window; and (2) when the link is lost while the last KNOWN level of the session was
|
|
/// Degraded (below 200), the other endpoint is probed before the first reconnect attempt and, if it
|
|
/// answers Healthy, the connection switches straight to it instead of spending the retry count on the
|
|
/// endpoint that announced it was degraded. Both keep the "Healthy and higher" rule and the dwell; a
|
|
/// pair that only ever reports Healthy levels (250/240) never meets either condition.
|
|
/// </para>
|
|
/// </summary>
|
|
public partial class DataConnectionActor
|
|
{
|
|
/// <summary>The lowest ServiceLevel in the OPC UA Healthy band (Part 4 §6.6.2.4.2).</summary>
|
|
internal const byte HealthyServiceLevelMinimum = 200;
|
|
|
|
/// <summary>
|
|
/// Part 4 §6.6.2.4.2 "Maintenance": the server is not available for use — OtOpcUa reports it while
|
|
/// it is shutting down or its endpoint has failed. Skips the degraded window (ScadaBridge#141).
|
|
/// </summary>
|
|
internal const byte MaintenanceServiceLevel = 0;
|
|
|
|
private const string ServiceLevelPollTimerKey = "servicelevel-poll";
|
|
|
|
private ServiceLevelFailoverPolicy _serviceLevelPolicy;
|
|
|
|
/// <summary>When the current unbroken run of Degraded samples began; null when not degraded.</summary>
|
|
private DateTimeOffset? _degradedSince;
|
|
|
|
/// <summary>When the last ServiceLevel-driven switch happened (dwell / anti-flap).</summary>
|
|
private DateTimeOffset _lastServiceLevelSwitchAt = DateTimeOffset.MinValue;
|
|
|
|
private bool _serviceLevelReadInFlight;
|
|
private bool _serviceLevelProbeInFlight;
|
|
|
|
/// <summary>True until the first sample of a session is evaluated (connect-time preference).</summary>
|
|
private bool _serviceLevelConnectCheckPending;
|
|
|
|
/// <summary>
|
|
/// The last level this session actually read (unknown samples do not overwrite it); null when
|
|
/// none has been read. Drives the lost-link probe (ScadaBridge#141).
|
|
/// </summary>
|
|
private byte? _lastKnownServiceLevel;
|
|
|
|
/// <summary>
|
|
/// True while the lost-link probe of the other endpoint is outstanding; the first reconnect
|
|
/// attempt is held until it answers (ScadaBridge#141).
|
|
/// </summary>
|
|
private bool _disconnectProbePending;
|
|
|
|
/// <summary>
|
|
/// True once ServiceLevel 0 has started a probe in the current degraded streak: 0 skips the window
|
|
/// once, so a peer that is not Healthy is then re-probed once per window, not on every poll.
|
|
/// </summary>
|
|
private bool _goingAwayProbeStarted;
|
|
|
|
/// <summary>When the outstanding lost-link probe started (to shorten the reconnect wait after it).</summary>
|
|
private DateTimeOffset _disconnectProbeStartedAt;
|
|
|
|
/// <summary>Why <see cref="BecomeReconnecting"/> is re-establishing the link.</summary>
|
|
internal enum ReconnectCause
|
|
{
|
|
/// <summary>The link was lost (disconnect, connection-level failure).</summary>
|
|
ConnectionLost,
|
|
|
|
/// <summary>An in-place reconfiguration swapped the adapter.</summary>
|
|
Reconfigured,
|
|
|
|
/// <summary>A sustained Degraded ServiceLevel swapped to the other endpoint (#138).</summary>
|
|
ServiceLevelFailover,
|
|
}
|
|
|
|
/// <summary>
|
|
/// True when this connection's ServiceLevel is watched: the policy is enabled, there is a
|
|
/// backup to go to, and the live adapter can read a ServiceLevel.
|
|
/// </summary>
|
|
private bool ServiceLevelFailoverInForce =>
|
|
_serviceLevelPolicy.Enabled && _backupConfig != null && _adapter is IServiceLevelReadable;
|
|
|
|
/// <summary>Called on entering Connected. Arms the poll (first tick immediately).</summary>
|
|
private void StartServiceLevelMonitoring()
|
|
{
|
|
ResetServiceLevelSession();
|
|
if (!ServiceLevelFailoverInForce)
|
|
return;
|
|
|
|
_serviceLevelConnectCheckPending = true;
|
|
Timers.StartPeriodicTimer(ServiceLevelPollTimerKey, ServiceLevelPollTick.Instance,
|
|
TimeSpan.Zero, _options.ServiceLevelPollInterval);
|
|
}
|
|
|
|
/// <summary>Called on leaving Connected. Results still in flight are fenced by generation.</summary>
|
|
private void StopServiceLevelMonitoring()
|
|
{
|
|
Timers.Cancel(ServiceLevelPollTimerKey);
|
|
ResetServiceLevelSession();
|
|
}
|
|
|
|
private void ResetServiceLevelSession()
|
|
{
|
|
_degradedSince = null;
|
|
_serviceLevelReadInFlight = false;
|
|
_serviceLevelProbeInFlight = false;
|
|
_serviceLevelConnectCheckPending = false;
|
|
_lastKnownServiceLevel = null;
|
|
_goingAwayProbeStarted = false;
|
|
}
|
|
|
|
private void HandleServiceLevelPollTick()
|
|
{
|
|
// One read at a time, and none while the other endpoint is being probed: the probe's
|
|
// verdict is taken against the level it started from.
|
|
if (!ServiceLevelFailoverInForce || _serviceLevelReadInFlight || _serviceLevelProbeInFlight)
|
|
return;
|
|
|
|
_serviceLevelReadInFlight = true;
|
|
var generation = _adapterGeneration;
|
|
var reader = (IServiceLevelReadable)_adapter;
|
|
var timeout = _options.ServiceLevelProbeTimeout;
|
|
Task.Run(() => reader.ReadServiceLevelAsync().WaitAsync(timeout))
|
|
.ContinueWith(t => new ServiceLevelSampled(generation,
|
|
t.IsCompletedSuccessfully ? t.Result : null), TaskScheduler.Default)
|
|
.PipeTo(_self);
|
|
}
|
|
|
|
private void HandleServiceLevelSampled(ServiceLevelSampled sampled)
|
|
{
|
|
if (sampled.AdapterGeneration != _adapterGeneration)
|
|
return;
|
|
|
|
_serviceLevelReadInFlight = false;
|
|
var connectCheck = _serviceLevelConnectCheckPending;
|
|
_serviceLevelConnectCheckPending = false;
|
|
if (sampled.Level is { } known)
|
|
_lastKnownServiceLevel = known;
|
|
|
|
if (sampled.Level is not { } level || level >= HealthyServiceLevelMinimum)
|
|
{
|
|
// Healthy, or unknown: either way the run of Degraded samples is broken. Unknown never
|
|
// counts toward a switch — acting on missing information is how a pair flaps.
|
|
if (_degradedSince != null)
|
|
_log.Info("[{0}] {1} endpoint ServiceLevel is {2} — degraded watch cleared",
|
|
_connectionName, _activeEndpoint, sampled.Level?.ToString(CultureInfo.InvariantCulture) ?? "unknown");
|
|
_degradedSince = null;
|
|
_goingAwayProbeStarted = false;
|
|
return;
|
|
}
|
|
|
|
var now = DateTimeOffset.UtcNow;
|
|
// ScadaBridge#141: 0 means the server is going away (graceful stop) — it will not be there
|
|
// for a full window, so the other endpoint is checked now. Still "Healthy and higher" + dwell.
|
|
var goingAway = level == MaintenanceServiceLevel && !_goingAwayProbeStarted;
|
|
if (_degradedSince is null)
|
|
{
|
|
_degradedSince = now;
|
|
_log.Warning("[{0}] {1} endpoint reports ServiceLevel {2} (Degraded band, < {3}) — "
|
|
+ "will check the other endpoint {4}",
|
|
_connectionName, _activeEndpoint, level, HealthyServiceLevelMinimum,
|
|
connectCheck ? "now (connect-time preference)"
|
|
: goingAway ? "now (ServiceLevel 0: the server is going away)"
|
|
: $"if it persists for {_serviceLevelPolicy.DegradedWindow.TotalSeconds:F0}s");
|
|
}
|
|
|
|
if (!connectCheck && !goingAway && now - _degradedSince.Value < _serviceLevelPolicy.DegradedWindow)
|
|
return;
|
|
|
|
if (now - _lastServiceLevelSwitchAt < _serviceLevelPolicy.MinDwell)
|
|
{
|
|
_log.Debug("[{0}] ServiceLevel {1} still Degraded but the last ServiceLevel switch was {2:F0}s ago "
|
|
+ "(dwell {3:F0}s) — staying", _connectionName, level,
|
|
(now - _lastServiceLevelSwitchAt).TotalSeconds, _serviceLevelPolicy.MinDwell.TotalSeconds);
|
|
return;
|
|
}
|
|
|
|
if (goingAway)
|
|
_goingAwayProbeStarted = true;
|
|
StartServiceLevelProbe(level);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Reads the OTHER endpoint's ServiceLevel through a short-lived adapter built from its
|
|
/// configuration — connect, read, dispose — off the actor thread, bounded by
|
|
/// <see cref="DataConnectionOptions.ServiceLevelProbeTimeout"/>. The live adapter is untouched.
|
|
/// </summary>
|
|
private void StartServiceLevelProbe(byte currentLevel, bool afterDisconnect = false)
|
|
{
|
|
if (!afterDisconnect)
|
|
_serviceLevelProbeInFlight = true;
|
|
var generation = _adapterGeneration;
|
|
var otherConfig = _activeEndpoint == ActiveEndpoint.Primary ? _backupConfig! : _primaryConfig;
|
|
var factory = _factory;
|
|
var protocol = _protocolType;
|
|
var timeout = _options.ServiceLevelProbeTimeout;
|
|
|
|
Task.Run(() => ProbeServiceLevelAsync(factory, protocol, otherConfig).WaitAsync(timeout))
|
|
.ContinueWith(t => t.IsCompletedSuccessfully
|
|
? new ServiceLevelProbed(generation, currentLevel, t.Result.Level, t.Result.Error, afterDisconnect)
|
|
: new ServiceLevelProbed(generation, currentLevel, null,
|
|
t.Exception?.GetBaseException() is TimeoutException
|
|
? $"no answer within {timeout.TotalSeconds:F0}s"
|
|
: t.Exception?.GetBaseException().Message ?? "probe cancelled",
|
|
afterDisconnect),
|
|
TaskScheduler.Default)
|
|
.PipeTo(_self);
|
|
}
|
|
|
|
private static async Task<(byte? Level, string? Error)> ProbeServiceLevelAsync(
|
|
IDataConnectionFactory factory, string protocol, IDictionary<string, string> config)
|
|
{
|
|
IDataConnection? probe = null;
|
|
try
|
|
{
|
|
probe = factory.Create(protocol, config);
|
|
if (probe is not IServiceLevelReadable reader)
|
|
return (null, "the adapter cannot read a ServiceLevel");
|
|
|
|
await probe.ConnectAsync(config).ConfigureAwait(false);
|
|
var level = await reader.ReadServiceLevelAsync().ConfigureAwait(false);
|
|
return (level, level is null ? "ServiceLevel unreadable" : null);
|
|
}
|
|
catch (Exception ex)
|
|
{
|
|
return (null, ex.GetBaseException().Message);
|
|
}
|
|
finally
|
|
{
|
|
// Fire-and-forget: closing a session against a black-holed server can block for the
|
|
// operation timeout, and the probe's verdict must not wait for it.
|
|
if (probe != null)
|
|
_ = probe.DisposeAsync().AsTask().ContinueWith(
|
|
t => _ = t.Exception, TaskContinuationOptions.OnlyOnFaulted);
|
|
}
|
|
}
|
|
|
|
private void HandleServiceLevelProbed(ServiceLevelProbed probed)
|
|
{
|
|
// A lost-link probe belongs to the Reconnecting state (HandleDisconnectProbed).
|
|
if (probed.AfterDisconnect || probed.AdapterGeneration != _adapterGeneration)
|
|
return;
|
|
|
|
_serviceLevelProbeInFlight = false;
|
|
if (!ServiceLevelFailoverInForce || _degradedSince is null)
|
|
return;
|
|
|
|
var other = _activeEndpoint == ActiveEndpoint.Primary ? ActiveEndpoint.Backup : ActiveEndpoint.Primary;
|
|
var now = DateTimeOffset.UtcNow;
|
|
|
|
if (probed.OtherLevel is not { } otherLevel)
|
|
{
|
|
_log.Warning("[{0}] {1} endpoint ServiceLevel {2} is Degraded but the {3} endpoint is not "
|
|
+ "available ({4}) — staying", _connectionName, _activeEndpoint, probed.CurrentLevel, other,
|
|
probed.Error);
|
|
_degradedSince = now; // re-arm: look again after another full window
|
|
return;
|
|
}
|
|
|
|
if (otherLevel < HealthyServiceLevelMinimum || otherLevel <= probed.CurrentLevel)
|
|
{
|
|
_log.Warning("[{0}] {1} endpoint ServiceLevel {2} is Degraded and the {3} endpoint reports {4} "
|
|
+ "(not a Healthy, higher level) — staying", _connectionName, _activeEndpoint,
|
|
probed.CurrentLevel, other, otherLevel);
|
|
_degradedSince = now;
|
|
return;
|
|
}
|
|
|
|
var degradedFor = now - _degradedSince.Value;
|
|
SwitchForServiceLevel(probed.CurrentLevel, otherLevel,
|
|
$"ServiceLevel {probed.CurrentLevel} Degraded for {degradedFor.TotalSeconds:F0}s");
|
|
BecomeReconnecting(ReconnectCause.ServiceLevelFailover);
|
|
}
|
|
|
|
/// <summary>
|
|
/// The endpoint switch shared by the Connected-state and the lost-link ServiceLevel triggers:
|
|
/// flips the adapter, resets both connection-failure counters, starts the dwell and logs it.
|
|
/// The caller re-arms the reconnect.
|
|
/// </summary>
|
|
private void SwitchForServiceLevel(byte currentLevel, byte otherLevel, string why)
|
|
{
|
|
var previousEndpoint = SwitchToOtherEndpoint();
|
|
_consecutiveFailures = 0;
|
|
_consecutiveUnstableDisconnects = 0;
|
|
_lastServiceLevelSwitchAt = DateTimeOffset.UtcNow;
|
|
|
|
_log.Warning("[{0}] Failing over from {1} to {2} ({3}; {2} reports {4})",
|
|
_connectionName, previousEndpoint, _activeEndpoint, why, otherLevel);
|
|
|
|
if (_siteEventLogger != null)
|
|
{
|
|
_ = _siteEventLogger.LogEventAsync(
|
|
"connection", "Warning", null, _connectionName,
|
|
$"Failover from {previousEndpoint} to {_activeEndpoint} (ServiceLevel)",
|
|
$"{previousEndpoint}: {why} (last ServiceLevel {currentLevel}); {_activeEndpoint} reports {otherLevel}");
|
|
}
|
|
}
|
|
|
|
/// <summary>
|
|
/// ScadaBridge#141 — called by <see cref="BecomeReconnecting"/> for a LOST link. When the session's
|
|
/// last known ServiceLevel was Degraded (below 200: the server had said it was not the one to be
|
|
/// on, typically 0 during a graceful stop), the other endpoint is probed before the first reconnect
|
|
/// attempt instead of retrying the endpoint that is going away. Not when the policy is not in
|
|
/// force, the session never read a Degraded level (250/240 pairs, unknown-only), or the dwell of
|
|
/// the previous ServiceLevel switch has not passed.
|
|
/// </summary>
|
|
/// <param name="lastKnownLevel">The ended session's last known level, captured before it was reset.</param>
|
|
/// <returns>True when the probe was started; the caller must then NOT arm the reconnect timer.</returns>
|
|
private bool TryStartDisconnectProbe(byte? lastKnownLevel)
|
|
{
|
|
if (lastKnownLevel is not { } level || level >= HealthyServiceLevelMinimum || !ServiceLevelFailoverInForce)
|
|
return false;
|
|
|
|
var sinceSwitch = DateTimeOffset.UtcNow - _lastServiceLevelSwitchAt;
|
|
if (sinceSwitch < _serviceLevelPolicy.MinDwell)
|
|
{
|
|
_log.Info("[{0}] Link lost after ServiceLevel {1}, but the last ServiceLevel switch was {2:F0}s ago "
|
|
+ "(dwell {3:F0}s) — normal reconnect cycle", _connectionName, level,
|
|
sinceSwitch.TotalSeconds, _serviceLevelPolicy.MinDwell.TotalSeconds);
|
|
return false;
|
|
}
|
|
|
|
_log.Warning("[{0}] Link to the {1} endpoint lost after it reported ServiceLevel {2} — checking the "
|
|
+ "other endpoint before retrying", _connectionName, _activeEndpoint, level);
|
|
_disconnectProbePending = true;
|
|
_disconnectProbeStartedAt = DateTimeOffset.UtcNow;
|
|
StartServiceLevelProbe(level, afterDisconnect: true);
|
|
return true;
|
|
}
|
|
|
|
/// <summary>
|
|
/// ScadaBridge#141 — the lost-link probe's verdict (Reconnecting state). A Healthy level on the
|
|
/// other endpoint switches to it and reconnects at once; anything else releases the held reconnect
|
|
/// into the ordinary retry cycle on the same endpoint, minus the time the probe already took.
|
|
/// </summary>
|
|
private void HandleDisconnectProbed(ServiceLevelProbed probed)
|
|
{
|
|
if (!probed.AfterDisconnect || !_disconnectProbePending || probed.AdapterGeneration != _adapterGeneration)
|
|
return;
|
|
|
|
_disconnectProbePending = false;
|
|
var other = _activeEndpoint == ActiveEndpoint.Primary ? ActiveEndpoint.Backup : ActiveEndpoint.Primary;
|
|
|
|
if (probed.OtherLevel is { } otherLevel
|
|
&& otherLevel >= HealthyServiceLevelMinimum && otherLevel > probed.CurrentLevel)
|
|
{
|
|
SwitchForServiceLevel(probed.CurrentLevel, otherLevel,
|
|
$"link lost after ServiceLevel {probed.CurrentLevel}");
|
|
Timers.StartSingleTimer("reconnect", new AttemptConnect(), TimeSpan.Zero);
|
|
return;
|
|
}
|
|
|
|
_log.Warning("[{0}] Link to the {1} endpoint lost after ServiceLevel {2}, but the {3} endpoint {4} — "
|
|
+ "normal reconnect cycle", _connectionName, _activeEndpoint, probed.CurrentLevel, other,
|
|
probed.OtherLevel is { } l ? $"reports {l} (not a Healthy, higher level)" : $"is not available ({probed.Error})");
|
|
var remaining = _options.ReconnectInterval - (DateTimeOffset.UtcNow - _disconnectProbeStartedAt);
|
|
Timers.StartSingleTimer("reconnect", new AttemptConnect(),
|
|
remaining > TimeSpan.Zero ? remaining : TimeSpan.Zero);
|
|
}
|
|
|
|
/// <summary>Poll tick for the connected endpoint's ServiceLevel.</summary>
|
|
internal sealed record ServiceLevelPollTick
|
|
{
|
|
/// <summary>The single instance.</summary>
|
|
public static readonly ServiceLevelPollTick Instance = new();
|
|
}
|
|
|
|
/// <summary>One ServiceLevel sample of the connected endpoint (null = unknown).</summary>
|
|
internal sealed record ServiceLevelSampled(int AdapterGeneration, byte? Level);
|
|
|
|
/// <summary>
|
|
/// The other endpoint's ServiceLevel (null = unreachable / unreadable, see Error).
|
|
/// <paramref name="AfterDisconnect"/> marks the lost-link probe (ScadaBridge#141), which only the
|
|
/// Reconnecting state acts on.
|
|
/// </summary>
|
|
internal sealed record ServiceLevelProbed(
|
|
int AdapterGeneration, byte CurrentLevel, byte? OtherLevel, string? Error, bool AfterDisconnect = false);
|
|
}
|
|
|
|
/// <summary>
|
|
/// The connection-level ServiceLevel failover settings, read from the PRIMARY endpoint's flattened
|
|
/// configuration (<see cref="OpcUaServiceLevelFailoverConfig"/>). Absent keys mean the defaults.
|
|
/// </summary>
|
|
internal readonly record struct ServiceLevelFailoverPolicy(bool Enabled, TimeSpan DegradedWindow, TimeSpan MinDwell)
|
|
{
|
|
/// <summary>Parses the policy; malformed or out-of-range values fall back to safe values.</summary>
|
|
/// <param name="primaryConfig">The primary endpoint's flattened configuration.</param>
|
|
/// <returns>The policy in force.</returns>
|
|
public static ServiceLevelFailoverPolicy From(IDictionary<string, string>? primaryConfig)
|
|
{
|
|
var enabled = true;
|
|
var window = OpcUaServiceLevelFailoverConfig.DefaultDegradedWindowSeconds;
|
|
var dwell = OpcUaServiceLevelFailoverConfig.DefaultMinDwellSeconds;
|
|
|
|
if (primaryConfig != null)
|
|
{
|
|
if (primaryConfig.TryGetValue(OpcUaEndpointConfigSerializer.ServiceLevelFailoverEnabledKey, out var e)
|
|
&& bool.TryParse(e, out var parsedEnabled))
|
|
enabled = parsedEnabled;
|
|
if (primaryConfig.TryGetValue(OpcUaEndpointConfigSerializer.ServiceLevelFailoverWindowKey, out var w)
|
|
&& int.TryParse(w, NumberStyles.Integer, CultureInfo.InvariantCulture, out var parsedWindow))
|
|
window = Math.Max(1, parsedWindow);
|
|
if (primaryConfig.TryGetValue(OpcUaEndpointConfigSerializer.ServiceLevelFailoverDwellKey, out var d)
|
|
&& int.TryParse(d, NumberStyles.Integer, CultureInfo.InvariantCulture, out var parsedDwell))
|
|
dwell = Math.Max(0, parsedDwell);
|
|
}
|
|
|
|
return new ServiceLevelFailoverPolicy(enabled, TimeSpan.FromSeconds(window), TimeSpan.FromSeconds(dwell));
|
|
}
|
|
}
|