Files
ScadaBridge/tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests/Actors
Joseph Doherty 4b6ff49822 fix(dcl+centralui): MxGateway tag browse — lazy attributes, frame-size cap, wider scrollable picker
Expanding a Galaxy object in the tag picker hung on "loading…": the browse
reply inlined every child's full attribute set (~152 KB), exceeding Akka's
128 KB remote frame, and remoting silently discarded the oversized reply.

Browse path (DataConnectionLayer):
- RealMxGatewayClient: navigation now uses BrowseChildren(include_attributes=
  false) — child objects only — and an object's own attributes load lazily via
  DiscoverHierarchy(root, max_depth=0) when it's expanded. Payload drops from
  ~152 KB/level to a few KB. Seam contract unchanged.
- DataConnectionActor.CapBrowseChildren: protocol-agnostic byte-budget cap
  (~100 KB) on every BrowseNodeResult before it crosses the site→central
  frame, OR-ing the adapter's own Truncated flag. Byte budget, not a count —
  the only bound that holds regardless of NodeId/attribute-name length.
- RealOpcUaClient: requestedMaxReferencesPerNode 1000 → 500 to narrow the
  window before the byte budget applies.
- Graceful gRPC Unimplemented handling → NotSupportedException →
  BrowseFailureKind.NotBrowsable with an actionable message (older gateway
  builds lacking BrowseChildren).

Picker UI (CentralUI):
- NodeBrowserDialog: modal-lg → modal-xl; new scoped .razor.css caps the tree
  at 55vh with its own scrollbar so manual entry + Select/Cancel stay visible.
- Protocol-agnostic failure messages (was hardcoded "OPC UA …"); renamed the
  leftover opcua-browser-tree class to node-browser-tree.

Tests: new frame-budget cap test + NotSupported=>NotBrowsable mapping test;
DCL suite 88/88. Doc: Component-DataConnectionLayer.md records the lazy
attribute-light browse and the frame-size guard.
2026-05-29 09:53:19 -04:00
..