Joseph Doherty 26ab6f8f09 fix(dcl): generation-fence ConnectResult + roll back failed OPC UA subscribe batches (arch-review 2026-08-19 P2-3 + P2-4)
P2-3. ConnectResult was the last piped completion with no adapter generation on
it, so a connect launched against generation N and answered after the adapter had
been swapped (failover, or the row-97 in-place reconfigure) was applied to its
REPLACEMENT. A stale success drove ReSubscribeAll + BecomeConnected against an
adapter that had never connected, and the replacement's own result then landed in
the Connected state where nothing handles it. With a bad new endpoint the batch
subscribes failed at connection level with a log line only, no AdapterDisconnected
ever fired, and the idempotent-reconfigure guard refused a re-send of the same
configuration — only a restart recovered the connection. A stale FAILURE was as
wrong the other way: it counted toward failover and re-armed the reconnect timer
underneath the attempt genuinely in flight.

HandleAttemptConnect now stamps the generation and both handlers open with the
same guard the subscribe leg got in c4d3c8b8, dropping a mismatched result whole.
The adapter instance is deliberately NOT carried: unlike a subscribe completion a
connect result holds no adapter-scoped handles to release, and SwapAdapter has
already disposed the outgoing adapter. Dropping cannot wedge the machine — every
generation bump (CountFailureAndMaybeFailover, BecomeReconnecting's failover
branch, HandleReconfigure through it) arms an AttemptConnect for the new
generation, and the state stays Connecting/Reconnecting until that answers.

P2-4. CreateSubscriptionsCoreAsync registers each monitored item as it places it
(_callbacks, _itemShard, shard budget, the SDK subscription's item list) and only
then issues ApplyChanges, so a throw there propagated with every registration
still in place and nothing holding a handle to release them. The actor reads the
throw as a whole-chunk fault and re-issues the SAME batch on its backoff timer, so
each probe grew the bookkeeping again. Placement + apply moved to
PlaceAndApplyAsync behind a try/catch that unwinds via the existing
ReleaseFailedItem (per-item try, so one failure neither stops the rest nor
replaces the original fault); no ApplyChanges is re-issued, and items a partial
apply did reach the server with are reclaimed when the shard and session are torn
down on reconnect.

That reconnect is the other half: IsConnectionLevelFailure knew nothing about
ServiceResultException, which is how the SDK reports a dead session — so a dead
session classified as a per-tag resolution failure for the whole chunk. It now
also matches a narrow set of session/channel status codes (BadSessionIdInvalid,
BadSessionClosed, BadSessionNotActivated, BadSecureChannelClosed,
BadSecureChannelIdInvalid, BadServerNotConnected, BadConnectionClosed,
BadCommunicationError, BadNotConnected). Per-node codes such as BadNodeIdUnknown
stay per-tag — that is exactly the device-still-booting case the resolution timer
exists for.

Tests: DataConnectionStaleConnectResultTests (stale success neither connects nor
re-subscribes against the new adapter; stale failure does not disturb the current
attempt; the current generation's result is still processed after a stale drop) —
all 3 fail with the guards removed. DataConnectionOpcUaFaultClassificationTests
(bad-session drives reconnect — fails unfixed; bad-node-id stays per-tag).
RealOpcUaClientBatchRollbackTests (no residual registrations after an ApplyChanges
throw; repeated failed batches do not grow the bookkeeping) — both fail with the
rollback removed. Full DCL suite 342/342 green.
2026-08-19 14:49:24 -04:00

212 lines
10 KiB
C#

using Akka.Actor;
using Akka.TestKit.Xunit2;
using NSubstitute;
using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol;
using ZB.MOM.WW.ScadaBridge.Commons.Messages.DataConnection;
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
using ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Actors;
using ZB.MOM.WW.ScadaBridge.HealthMonitoring;
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests.Actors;
/// <summary>
/// Arch-review 2026-08-19 <b>P2-3</b> — the connect leg of the stale-completion family that
/// <c>DataConnectionStaleCompletionTests</c> pins for the subscribe leg.
///
/// <para>
/// <b>The gap these pin.</b> <c>ConnectResult</c> was piped untagged, so a connect launched
/// against adapter generation N and answered after the adapter had been swapped (failover, or the
/// row-97 in-place reconfigure) was applied to its REPLACEMENT. A stale success drove
/// <c>ReSubscribeAll</c> and <c>BecomeConnected</c> against an adapter that had never connected;
/// the replacement's own result then landed in the Connected state, where nothing handles it. With
/// a bad new endpoint the batch subscribes failed at connection level with a log line only, no
/// <c>AdapterDisconnected</c> ever fired, and the idempotent-reconfigure guard refused a re-send
/// of the same configuration — only a restart recovered the connection. A stale FAILURE was just
/// as wrong: it counted toward failover and re-armed the reconnect timer underneath the attempt
/// that was genuinely in flight.
/// </para>
///
/// <para>
/// The state machine must also stay able to finish the CURRENT attempt after a stale result was
/// dropped — Connecting/Reconnecting is held until the matching-generation result arrives.
/// </para>
/// </summary>
[Collection("DataConnectionManagerActor")]
public class DataConnectionStaleConnectResultTests : TestKit
{
private const string FirstEndpoint = "opc.tcp://first-plc:4840";
private const string MidEndpoint = "opc.tcp://mid-plc:4840";
private const string LastEndpoint = "opc.tcp://last-plc:4840";
private const string Tag = "sensor/temp";
private readonly ISiteHealthCollector _health = Substitute.For<ISiteHealthCollector>();
private readonly IDataConnectionFactory _factory = Substitute.For<IDataConnectionFactory>();
private readonly DataConnectionOptions _options = new()
{
ReconnectInterval = TimeSpan.FromMilliseconds(100),
TagResolutionRetryInterval = TimeSpan.FromMilliseconds(200),
WriteTimeout = TimeSpan.FromSeconds(5),
SeedReadMaxAttempts = 1,
SeedReadRetryDelay = TimeSpan.FromMilliseconds(10)
};
private static Dictionary<string, string> Config(string endpoint) =>
new() { ["Endpoint"] = endpoint };
private IActorRef CreateConnectionActor(string name, IDataConnection adapter) =>
Sys.ActorOf(Props.Create(() =>
new DataConnectionActor(
name, adapter, _options, _health, _factory, "OpcUa",
Config(FirstEndpoint), null, 3)), name);
private void ExpectAdapterFor(string endpoint, IDataConnection adapter) =>
_factory.Create("OpcUa", Arg.Is<IDictionary<string, string>>(d => d["Endpoint"] == endpoint))
.Returns(adapter);
/// <summary>An adapter whose connect completes when <paramref name="connect"/> does.</summary>
private static IDataConnection Adapter(Task connect, string subscriptionId)
{
var adapter = Substitute.For<IDataConnection>();
adapter.ConnectAsync(Arg.Any<IDictionary<string, string>>(), Arg.Any<CancellationToken>())
.Returns(connect);
adapter.Status.Returns(ConnectionHealth.Connected);
adapter.SubscribeAsync(Arg.Any<string>(), Arg.Any<SubscriptionCallback>(), Arg.Any<CancellationToken>())
.Returns(subscriptionId);
adapter.ReadAsync(Arg.Any<string>(), Arg.Any<CancellationToken>())
.Returns(new ReadResult(false, null, null));
return adapter;
}
private int HealthTransitions(string connectionName, ConnectionHealth health) =>
_health.ReceivedCalls().Count(c =>
c.GetMethodInfo().Name == nameof(ISiteHealthCollector.UpdateConnectionHealth) &&
c.GetArguments() is [string name, ConnectionHealth reported, ..] &&
name == connectionName && reported == health);
private static int CallCount(IDataConnection adapter, string method) =>
adapter.ReceivedCalls().Count(c => c.GetMethodInfo().Name == method);
/// <summary>
/// Drives the actor to: connected on the first adapter with one live tag subscription, then
/// reconfigured onto <paramref name="mid"/> (whose connect is still in flight), then
/// reconfigured again onto <paramref name="last"/> (whose connect is also still in flight).
/// The mid adapter's pending connect is now two generations stale.
/// </summary>
private IActorRef ArrangeTwoGenerationsBehind(
string name, IDataConnection first, IDataConnection mid, IDataConnection last)
{
ExpectAdapterFor(MidEndpoint, mid);
ExpectAdapterFor(LastEndpoint, last);
var actor = CreateConnectionActor(name, first);
AwaitCondition(() => HealthTransitions(name, ConnectionHealth.Connected) >= 1,
TimeSpan.FromSeconds(5), TimeSpan.FromMilliseconds(10));
var probe = CreateTestProbe();
probe.Send(actor, new SubscribeTagsRequest("c1", "inst1", name, [Tag], DateTimeOffset.UtcNow));
probe.FishForMessage<SubscribeTagsResponse>(m => m.Success, TimeSpan.FromSeconds(5));
actor.Tell(new ReconfigureConnectionCommand(name, "OpcUa", Config(MidEndpoint), null, 3));
AwaitCondition(() => CallCount(mid, nameof(IDataConnection.ConnectAsync)) >= 1,
TimeSpan.FromSeconds(5), TimeSpan.FromMilliseconds(10));
actor.Tell(new ReconfigureConnectionCommand(name, "OpcUa", Config(LastEndpoint), null, 3));
AwaitCondition(() => CallCount(last, nameof(IDataConnection.ConnectAsync)) >= 1,
TimeSpan.FromSeconds(5), TimeSpan.FromMilliseconds(10));
return actor;
}
/// <summary>
/// The headline case: a success from the adapter the operator has just corrected AWAY from
/// must not declare the connection up, and must not re-issue the subscription registry
/// against the replacement adapter that has not connected yet.
///
/// <para><b>Fails before the fix:</b> the actor entered Connected and re-subscribed
/// <c>Tag</c> on the never-connected last adapter.</para>
/// </summary>
[Fact]
public void StaleConnectSuccess_DoesNotConnect_AndDoesNotResubscribeAgainstTheNewAdapter()
{
const string name = "stale-connect-success";
var midGate = new TaskCompletionSource();
var lastGate = new TaskCompletionSource();
var first = Adapter(Task.CompletedTask, "sub-first");
var mid = Adapter(midGate.Task, "sub-mid");
var last = Adapter(lastGate.Task, "sub-last");
ArrangeTwoGenerationsBehind(name, first, mid, last);
// The two-generations-old connect finally answers — successfully.
midGate.SetResult();
// Settle: nothing here subscribes the default test actor, so this is purely a wait long
// enough for the piped result to have been received and dropped.
ExpectNoMsg(TimeSpan.FromMilliseconds(500));
Assert.Equal(1, HealthTransitions(name, ConnectionHealth.Connected));
Assert.Equal(0, CallCount(last, nameof(IDataConnection.SubscribeAsync)));
}
/// <summary>
/// A stale FAILURE must not touch the attempt that is genuinely in flight. Acting on it
/// counted toward the failover budget and re-armed the reconnect timer, so a second
/// <c>ConnectAsync</c> was launched against an adapter already connecting.
///
/// <para><b>Fails before the fix:</b> the last adapter was asked to connect a second time
/// one <c>ReconnectInterval</c> after the stale failure landed.</para>
/// </summary>
[Fact]
public void StaleConnectFailure_DoesNotDisturbTheCurrentAttempt()
{
const string name = "stale-connect-failure";
var midGate = new TaskCompletionSource();
var lastGate = new TaskCompletionSource();
var first = Adapter(Task.CompletedTask, "sub-first");
var mid = Adapter(midGate.Task, "sub-mid");
var last = Adapter(lastGate.Task, "sub-last");
ArrangeTwoGenerationsBehind(name, first, mid, last);
midGate.SetException(new Exception("connection refused"));
// Comfortably longer than ReconnectInterval, so a re-armed timer would have fired.
ExpectNoMsg(TimeSpan.FromMilliseconds(600));
Assert.Equal(1, CallCount(last, nameof(IDataConnection.ConnectAsync)));
Assert.Equal(1, HealthTransitions(name, ConnectionHealth.Connected));
}
/// <summary>
/// Dropping a stale result must not wedge the state machine: the actor stays in Reconnecting
/// and the CURRENT generation's own result is still processed normally — connection up, and
/// the whole subscription registry transparently re-subscribed against the live adapter.
/// </summary>
[Fact]
public void CurrentGenerationConnectResult_IsStillProcessed_AfterAStaleOneWasDropped()
{
const string name = "stale-connect-then-live";
var midGate = new TaskCompletionSource();
var lastGate = new TaskCompletionSource();
var first = Adapter(Task.CompletedTask, "sub-first");
var mid = Adapter(midGate.Task, "sub-mid");
var last = Adapter(lastGate.Task, "sub-last");
ArrangeTwoGenerationsBehind(name, first, mid, last);
midGate.SetResult();
ExpectNoMsg(TimeSpan.FromMilliseconds(300));
Assert.Equal(1, HealthTransitions(name, ConnectionHealth.Connected));
// Now the live adapter answers.
lastGate.SetResult();
AwaitCondition(() => HealthTransitions(name, ConnectionHealth.Connected) >= 2,
TimeSpan.FromSeconds(5), TimeSpan.FromMilliseconds(10));
AwaitCondition(() => CallCount(last, nameof(IDataConnection.SubscribeAsync)) >= 1,
TimeSpan.FromSeconds(5), TimeSpan.FromMilliseconds(10));
}
}