Joseph Doherty ee8a8e9d3d fix(site-runtime): step-log review — trace-flag-gated ES step scope, shared-script Log, formatter guard
Task 5 code-review follow-ups:
- I1: ExternalSystemHelper gates its TraceStepScope on a new isTraced ctor arg
  (default false for direct construction), not on `_traceSink is not null` — a
  traced run without an inline collector still writes durable ScriptLog rows
  that must name their step.
- I2 (design §5): an inline shared script now SHARES its caller's ScriptLogger
  via the new `sharedLog` ctor param — one line cap, one anchor, one closing
  row. Consequence documented on the Log property: a shared script's lines
  carry the PARENT run's ExecutionId and land on the parent's ScriptRun node.
- M3: TraceCapturingLogger swallows a throwing formatter — most of what it
  captures is best-effort "audit write failed" warnings logged from inside a
  catch block, and a formatting exception must not escape that path.
- Tests: ApiCall step attribution, traced-without-collector, shared-script
  logger sharing, nested batch/wait scope attribution + unwind, throwing
  formatter; test (c) now also pins the anti-recursion property (EmitLog must
  log through the undecorated logger).

CompileSurfaceParityTests stays red until Task 7 mirrors Log on ScriptCompileSurface.
2026-09-09 12:10:17 -04:00

190 lines
6.7 KiB
C#

using Microsoft.Extensions.Logging;
using ZB.MOM.WW.ScadaBridge.SiteRuntime.Scripts;
namespace ZB.MOM.WW.ScadaBridge.SiteRuntime.Tests.Scripts;
/// <summary>
/// Flow Debugger step logs (design 2026-09-09 D6): the decorator installed over the script
/// context's logger while a run is traced. It must forward everything the node would have logged
/// anyway, capture Information and above as <c>runtime</c> rows — including levels the node's own
/// minimum level suppresses, because they are trace data, not node log output — and never capture
/// Debug/Trace chatter.
/// </summary>
public class TraceCapturingLoggerTests
{
/// <summary>One row the sink's emitter received.</summary>
private sealed record Row(string Level, string Source, string Message, Exception? Exception, Guid? StepEventId);
/// <summary>An inner logger that records what it was asked to write, at a configurable minimum level.</summary>
private sealed class RecordingLogger(LogLevel minimum = LogLevel.Trace) : ILogger
{
public List<(LogLevel Level, string Message)> Entries { get; } = [];
public List<object?> Scopes { get; } = [];
public IDisposable? BeginScope<TState>(TState state) where TState : notnull
{
Scopes.Add(state);
return null;
}
public bool IsEnabled(LogLevel logLevel) => logLevel >= minimum;
public void Log<TState>(LogLevel level, EventId eventId, TState state, Exception? exception, Func<TState, Exception?, string> formatter) =>
Entries.Add((level, formatter(state, exception)));
}
private static (TraceCapturingLogger Logger, RecordingLogger Inner, List<Row> Rows) Make(LogLevel innerMinimum = LogLevel.Trace)
{
var inner = new RecordingLogger(innerMinimum);
var rows = new List<Row>();
var sink = new ScriptLogger(
new RecordingLogger(),
(level, source, message, exception, stepEventId) => rows.Add(new Row(level, source, message, exception, stepEventId)),
maxLines: 200,
instance: "CvdReactor01",
script: "OnHeartbeat",
executionId: Guid.NewGuid());
return (new TraceCapturingLogger(inner, sink), inner, rows);
}
[Fact]
public void Debug_IsForwarded_ButNotCaptured()
{
var (logger, inner, rows) = Make();
logger.LogDebug("internal chatter");
Assert.Single(inner.Entries);
Assert.Empty(rows);
}
[Fact]
public void Warning_IsCapturedAsARuntimeRow_WithItsException()
{
var (logger, inner, rows) = Make();
var boom = new TimeoutException("no reply");
logger.LogWarning(boom, "tag write timed out after {Ms} ms", 5_000);
Assert.Single(inner.Entries);
var row = Assert.Single(rows);
Assert.Equal("warn", row.Level);
Assert.Equal("runtime", row.Source);
Assert.Equal("tag write timed out after 5000 ms", row.Message);
Assert.Same(boom, row.Exception);
}
[Fact]
public void ErrorAndCritical_AreBothCapturedAsError()
{
var (logger, _, rows) = Make();
logger.LogError("bad");
logger.LogCritical("worse");
Assert.Equal(["error", "error"], rows.Select(r => r.Level));
}
[Fact]
public void InformationIsEnabled_EvenWhenTheInnerLoggerSaysNo()
{
// A node whose Serilog minimum is Warning must still contribute Information lines to a trace.
var (logger, inner, rows) = Make(innerMinimum: LogLevel.Warning);
Assert.False(inner.IsEnabled(LogLevel.Information));
Assert.True(logger.IsEnabled(LogLevel.Information));
logger.LogInformation("captured anyway");
Assert.Empty(inner.Entries);
var row = Assert.Single(rows);
Assert.Equal("info", row.Level);
Assert.Equal("captured anyway", row.Message);
}
[Fact]
public void BelowInformation_TheInnerLoggerDecidesEnablement()
{
var (logger, _, _) = Make(innerMinimum: LogLevel.Warning);
Assert.False(logger.IsEnabled(LogLevel.Debug));
}
[Fact]
public void ADisabledInnerLogger_IsNotWrittenTo_ButTheRowIsStillCaptured()
{
var (logger, inner, rows) = Make(innerMinimum: LogLevel.Critical);
logger.LogWarning("suppressed on the node");
Assert.Empty(inner.Entries);
Assert.Single(rows);
}
[Fact]
public void CapturedLines_CarryTheAmbientStepId()
{
var (logger, _, rows) = Make();
var stepId = Guid.NewGuid();
using (TraceStepScope.Enter(stepId))
{
logger.LogInformation("inside the helper");
}
Assert.Equal(stepId, Assert.Single(rows).StepEventId);
}
[Fact]
public void Ctor_RejectsAnAlreadyDecoratedLogger()
{
// Wrapping twice would forward each script line through two capture stages and emit two
// runtime rows per line — and would burn the run's line cap at double rate.
var (already, _, _) = Make();
var sink = new ScriptLogger(new RecordingLogger(), emit: null, maxLines: 200, "i", "s", null);
var ex = Assert.Throws<ArgumentException>(() => new TraceCapturingLogger(already, sink));
Assert.Equal("inner", ex.ParamName);
}
[Fact]
public void Ctor_RequiresBothCollaborators()
{
var sink = new ScriptLogger(new RecordingLogger(), emit: null, maxLines: 200, "i", "s", null);
Assert.Throws<ArgumentNullException>(() => new TraceCapturingLogger(null!, sink));
Assert.Throws<ArgumentNullException>(() => new TraceCapturingLogger(new RecordingLogger(), null!));
}
[Fact]
public void AThrowingFormatter_IsSwallowed_AndDropsOnlyThatLine()
{
// Review M3. Most of what this decorator captures is the runtime's own best-effort
// "audit write failed" warnings, logged from INSIDE a catch block: a formatter exception
// escaping here would replace the original failure with a formatting one on a path whose
// contract is that it never throws. The inner logger is disabled for this level so the
// decorator's OWN formatter call is the only one under test.
var (logger, inner, rows) = Make(innerMinimum: LogLevel.Critical);
logger.Log(LogLevel.Warning, new EventId(0), "state", null,
(_, _) => throw new InvalidOperationException("formatter broke"));
Assert.Empty(rows);
Assert.Empty(inner.Entries);
// …and the decorator keeps working for the next line.
logger.LogWarning("still alive");
Assert.Equal("still alive", Assert.Single(rows).Message);
}
[Fact]
public void BeginScope_DelegatesToTheInnerLogger()
{
var (logger, inner, _) = Make();
logger.BeginScope("state");
Assert.Equal(["state"], inner.Scopes);
}
}