Joseph Doherty 957db62df1 fix(site-runtime): deployment whose Instance Actor dies during init reports Failed, exactly-once reply (S6)
Success now requires BOTH persistence commit AND an InstanceActorInitialized
readiness signal from the actor's PreStart — persistence can commit before the
actor's async init has run or failed, so persistence alone must not report
Success. An actor that dies during init never signals readiness; the Terminated
fallback fails that deployment and rolls back the optimistic state. The
persisted-row rollback is deferred until the store commits so it cannot race the
optimistic write.

Deviation from plan Task 15: the plan's swallow-only guard did not handle the
persistence-first ordering (empirically the store commits before the Terminated
signal, so Success was reported for a dead actor). Added the readiness handshake
to make the join deterministic.
2026-07-09 00:33:40 -04:00
..