Files
ScadaBridge/tests
Joseph Doherty 9110a4eb01 fix(auditlog,health): harden hosted-service shutdown against disposed CTS
The host does not guarantee IHostedService.StopAsync is driven before the DI
container is disposed — WebApplicationFactory's teardown reaches Dispose first
— so cancelling the internal CTS from StopAsync threw ObjectDisposedException
and aborted the host's whole shutdown sequence. Four services shared the same
copy-pasted lifecycle and the same two races: StopAsync cancelling an already-
disposed CTS, and StartAsync reading _cts.Token lazily inside the Task.Run
lambda, which faults the loop task the host awaits when Dispose wins that race.

Each service now captures the token on the caller's thread, tolerates a
disposed CTS, and cancels-before-disposing so the loop is always signalled and
its pending Task.Delay sees a cancelled token rather than a dead source.
SiteAuditBacklogReporter also gains the outer OperationCanceledException guard
its sibling SiteAuditRetentionService already carried (arch-review 04 R2, R7),
without which a shutdown landing mid-probe threw TaskCanceledException out of
Host.StopAsync.

Surfaced while verifying the Gitea #15 test-harness fix: in Host.Tests the
aborted teardown skipped the fixture's env-var restore, contaminating every
later test in the run.

Refs: Gitea #15
2026-07-16 23:31:19 -04:00
..