90ce099928
Row 53 shipped the scadabridge.central.transport.import_sessions.open gauge
and a Warning log on a cap hit, but a log line is not something an operator
can alert on. Adds the companion counter
scadabridge.central.transport.import_sessions.rejected
on the existing ZB.MOM.WW.ScadaBridge meter, so no ObservedMeters allowlist
change is needed (an unlisted meter exports nothing, silently).
The emit point is deliberately narrow. BundleSessionStore.Open tests the cap
TWICE — once on entry and again after EvictExpired() — and only the second
test is a rejection: a store full of merely expired sessions reclaims a slot
and admits the caller. Counting the first would make the series fire
routinely on any node whose sweep had not yet run, turning a page-worthy
signal into background noise. Re-Opening an already-open session id skips
the cap block entirely and is likewise not counted.
The two instruments are diagnostic as a pair: rejections rising while the
gauge oscillates below the cap is genuine concurrency (raise the cap);
rejections rising while the gauge sits pinned at the cap is a session leak
(register row 43's signature), where raising the cap only defers the problem.
Tests assert a delta over a scoped action rather than an absolute value, so
they do not inherit the register row 32 static-state flake that makes
QueueDepthGaugeTests fail only under the full concurrent suite. Negative
controls cover under-cap, expired-reclaim, and duplicate-session-id.
Tests: 11 passed in BundleSessionObservabilityTests (6 existing + 5 new).