02:19:58 before: scadabridge-site-a-a active=503 scadabridge-site-a-b active=200 restarts A=1/2026-11-13T02:16:56.78136603Z B=0/2026-11-13T02:11:56.101105213Z (A ip 192.168.147.7)
02:19:59 partition ON (B drops all traffic to/from A)
02:20:26 DUAL-ACTIVE reached at +28s
02:20:43 end of hold (+45s): scadabridge-site-a-a active=200 scadabridge-site-a-b active=200
02:20:44 partition HEALED (+46s)
02:22:34 +110s after heal: A stayed, B RESTARTED
02:22:35 one active (scadabridge-site-a-a=200 scadabridge-site-a-b=503), "memberCount":2 "memberCount":2 — converged +111s after heal
02:22:55 final: scadabridge-site-a-a active=200 ready=200 restarts=1/2026-11-13T02:16:56.78136603Z | scadabridge-site-a-b active=503 ready=200 restarts=1/2026-11-13T02:22:33.72599839Z
result: restart=[+110s after heal: A stayed, B RESTARTED] converged=[+111s after heal] stable-samples=10
--- scadabridge-site-a-a [leader-auto-down] + quarantine lines
[02:20:10 WRN] [Site/scadabridge-site-a-a] [leader-auto-down] akka.tcp://scadabridge@scadabridge-site-a-b:8082 is unreachable; it will be downed if still unreachable after 00:00:15 (this node akka.tcp://scadabridge@scadabridge-site-a-a:8082 is leader: True)
[02:20:25 WRN] [Site/scadabridge-site-a-a] [leader-auto-down] DOWNING akka.tcp://scadabridge@scadabridge-site-a-b:8082: unreachable for 00:00:15 and this node (akka.tcp://scadabridge@scadabridge-site-a-a:8082) is leader
[02:21:01 WRN] [Site/scadabridge-site-a-a] [leader-auto-down] split from akka.tcp://scadabridge@scadabridge-site-a-b:8082: it is still running the incarnation this node (akka.tcp://scadabridge@scadabridge-site-a-a:8082) removed, so this node has shut it out. Giving it 00:01:00 to restart itself before the tiebreak (a frozen node
[02:22:01 WRN] [Site/scadabridge-site-a-a] [leader-auto-down] split from akka.tcp://scadabridge@scadabridge-site-a-b:8082: its old incarnation is still running 00:01:00 later and it has not restarted itself; both sides are shut out. Tiebreak says STAY: this node (akka.tcp://scadabridge@scadabridge-site-a-a:8082) has the lower ad
--- scadabridge-site-a-b [leader-auto-down] + quarantine lines
[02:20:11 WRN] [Site/scadabridge-site-a-b] [leader-auto-down] akka.tcp://scadabridge@scadabridge-site-a-a:8082 is unreachable; it will be downed if still unreachable after 00:00:15 (this node akka.tcp://scadabridge@scadabridge-site-a-b:8082 is leader: False)
[02:20:11 INF] [Site/scadabridge-site-a-b] [leader-auto-down] akka.tcp://scadabridge@scadabridge-site-a-b:8082 gained leadership (leader is now akka.tcp://scadabridge@scadabridge-site-a-b:8082); pending unreachable=[]
[02:20:26 WRN] [Site/scadabridge-site-a-b] [leader-auto-down] DOWNING akka.tcp://scadabridge@scadabridge-site-a-a:8082: unreachable for 00:00:15 and this node (akka.tcp://scadabridge@scadabridge-site-a-b:8082) is leader
[02:21:02 WRN] [Site/scadabridge-site-a-b] [leader-auto-down] split from akka.tcp://scadabridge@scadabridge-site-a-a:8082: it is still running the incarnation this node (akka.tcp://scadabridge@scadabridge-site-a-b:8082) removed, so this node has shut it out. Giving it 00:01:00 to restart itself before the tiebreak (a frozen node
[02:22:02 WRN] [Site/scadabridge-site-a-b] [leader-auto-down] split from akka.tcp://scadabridge@scadabridge-site-a-a:8082: its old incarnation is still running 00:01:00 later and it has not restarted itself; both sides are shut out. Tiebreak says RESTART: this node (akka.tcp://scadabridge@scadabridge-site-a-b:8082) has the highe
[02:22:02 INF] [Site/scadabridge-site-a-b] [leader-auto-down] akka.tcp://scadabridge@scadabridge-site-a-b:8082 lost leadership (leader is now none); pending unreachable=[]
[02:22:03 FTL] [Site/scadabridge-site-a-b] ActorSystem terminated outside host shutdown (SBR down / run-coordinated-shutdown-when-down / leader-auto-down shut-out restart). Stopping the host process with exit code 75 so the service supervisor restarts this node as a fresh incarnation.
[02:22:34 INF] [Site/scadabridge-site-a-b] [leader-auto-down] shut-out restart is ON for akka.tcp://scadabridge@scadabridge-site-a-b:8082: a node split from its pair peer restarts itself — at once if only it was removed, otherwise the higher address restarts after a 00:01:00 grace (ScadaBridge#132)
[02:22:34 INF] [Site/scadabridge-site-a-b] [leader-auto-down] started on akka.tcp://scadabridge@scadabridge-site-a-b:8082: leader=none (this node is leader: False), unreachable-after=00:00:15, already unreachable=[]