Files
ScadaBridge/tests/ZB.MOM.WW.ScadaBridge.SiteRuntime.Tests/SiteRuntimeOptionsValidatorTests.cs
T

61 lines
2.0 KiB
C#

using Microsoft.Extensions.Options;
namespace ZB.MOM.WW.ScadaBridge.SiteRuntime.Tests;
/// <summary>
/// <see cref="SiteRuntimeOptions"/> values size the staggered Instance-Actor
/// startup batches, the dedicated script-execution thread scheduler, and the
/// site-wide stream buffer. A zero/negative count crashes actor construction with
/// an opaque <see cref="ArgumentOutOfRangeException"/>; these tests assert the
/// <see cref="SiteRuntimeOptionsValidator"/> rejects a bad
/// <c>ScadaBridge:SiteRuntime</c> section with a clear, key-naming message.
/// </summary>
public class SiteRuntimeOptionsValidatorTests
{
private static ValidateOptionsResult Validate(SiteRuntimeOptions options) =>
new SiteRuntimeOptionsValidator().Validate(Options.DefaultName, options);
[Fact]
public void DefaultOptions_AreValid()
{
var result = Validate(new SiteRuntimeOptions());
Assert.True(result.Succeeded, result.FailureMessage);
}
[Fact]
public void ZeroStartupBatchSize_IsRejected()
{
var result = Validate(new SiteRuntimeOptions { StartupBatchSize = 0 });
Assert.True(result.Failed);
Assert.Contains("StartupBatchSize", result.FailureMessage);
}
[Fact]
public void ZeroScriptExecutionThreadCount_IsRejected()
{
var result = Validate(new SiteRuntimeOptions { ScriptExecutionThreadCount = 0 });
Assert.True(result.Failed);
Assert.Contains("ScriptExecutionThreadCount", result.FailureMessage);
}
[Fact]
public void ZeroStreamBufferSize_IsRejected()
{
var result = Validate(new SiteRuntimeOptions { StreamBufferSize = 0 });
Assert.True(result.Failed);
Assert.Contains("StreamBufferSize", result.FailureMessage);
}
[Fact]
public void NegativeStartupBatchDelayMs_IsRejected()
{
var result = Validate(new SiteRuntimeOptions { StartupBatchDelayMs = -1 });
Assert.True(result.Failed);
Assert.Contains("StartupBatchDelayMs", result.FailureMessage);
}
}