82f6fb949e
Both Flow Debugger and Debug View enable the shared InstancePicker as soon as _selectedSiteId lands, but Blazor renders at the site-change handler's first await — at which point the picker is still holding the PREVIOUS site's Areas / Instances lists. Typing into the field in that window (an operator, or Playwright's FillAsync, which waits only for "enabled") was silently lost: the picker compares both lists by reference, so the freshly-assigned lists read as "the site changed" and it clears the field text and closes the panel. Both pages now hold an _instancesLoading flag across the whole load — set before the first await, cleared in a finally so a fault or a site-scope refusal cannot leave the picker disabled forever — and fold it into the picker's Disabled expression. InstancePicker itself is unchanged. Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29