513fa1aa16
Comment/XML-doc changes only: - add summaries to ~10k test methods, fixtures, fakes and helpers (+ <param> on theories, <returns> on async Task methods, <inheritdoc/> on interface implementations the checker can resolve) - strip ~2.6k project-tracking references (WP*, P*-*, row-NN, Task N, #NN, Component-0NN) from comments, keeping the explanatory text; reword false positives in comments only - real docs on fakes implementing BCL/library interfaces (IDisposable, ILogger, IOptionsMonitor, IAsyncLifetime) - reword the last 5 src/ false positives (CWE-1236, failures-1, year-0001, M365) Only non-comment edits: four one-line nested classes split across lines so members can carry docs. Build 0 errors / 0 warnings.
61 lines
2.6 KiB
C#
61 lines
2.6 KiB
C#
using Akka.TestKit.Xunit2;
|
|
using Microsoft.Extensions.Logging.Abstractions;
|
|
using ZB.MOM.WW.ScadaBridge.HealthMonitoring;
|
|
using ZB.MOM.WW.ScadaBridge.SiteRuntime.Streaming;
|
|
|
|
namespace ZB.MOM.WW.ScadaBridge.SiteRuntime.Tests.Streaming;
|
|
|
|
/// <summary>
|
|
/// The hosted reporter must lift <see cref="SiteStreamManager.AlarmPublishDroppedCount"/>
|
|
/// onto the site health report via <see cref="ISiteHealthCollector"/>. Uses the real
|
|
/// collector (mirrors <c>ScriptSchedulerStatsReporterTests</c> — NSubstitute is not
|
|
/// referenced by this test project). The queue's own drop-counting mechanism is verified
|
|
/// deterministically and separately by
|
|
/// <see cref="Streaming.SiteStreamManagerTests.CreateAlarmPublishQueue_OverCapacity_DropsOldestAndInvokesCallback"/>;
|
|
/// this test proves the reporter's poll-and-push wiring runs correctly.
|
|
/// </summary>
|
|
public class SiteStreamAlarmDropReporterTests : TestKit, IDisposable
|
|
{
|
|
/// <inheritdoc />
|
|
void IDisposable.Dispose() => Shutdown();
|
|
|
|
/// <summary>Verifies that reporter pushes alarm drop count to collector.</summary>
|
|
/// <returns>A task that represents the asynchronous operation.</returns>
|
|
[Fact]
|
|
public async Task Reporter_PushesAlarmDropCountToCollector()
|
|
{
|
|
var options = new SiteRuntimeOptions { StreamBufferSize = 100 };
|
|
var collector = new SiteHealthCollector();
|
|
var streamManager = new SiteStreamManager(options, NullLogger<SiteStreamManager>.Instance);
|
|
streamManager.Initialize(Sys);
|
|
|
|
using var reporter = new SiteStreamAlarmDropReporter(
|
|
collector, streamManager, NullLogger<SiteStreamAlarmDropReporter>.Instance,
|
|
pollInterval: TimeSpan.FromMilliseconds(50));
|
|
|
|
await reporter.StartAsync(CancellationToken.None);
|
|
try
|
|
{
|
|
// The immediate first probe (no drops yet) must reach the report as 0 —
|
|
// proving the reporter actually ran and pushed a value, not that the field
|
|
// simply defaulted.
|
|
await WaitUntilAsync(() =>
|
|
collector.CollectReport("site-1").SiteStreamAlarmDropCount == streamManager.AlarmPublishDroppedCount);
|
|
|
|
var report = collector.CollectReport("site-1");
|
|
Assert.Equal(streamManager.AlarmPublishDroppedCount, report.SiteStreamAlarmDropCount);
|
|
}
|
|
finally
|
|
{
|
|
await reporter.StopAsync(CancellationToken.None);
|
|
}
|
|
}
|
|
|
|
private static async Task WaitUntilAsync(Func<bool> condition)
|
|
{
|
|
for (var i = 0; i < 100 && !condition(); i++)
|
|
await Task.Delay(50);
|
|
Assert.True(condition(), "condition not met within timeout");
|
|
}
|
|
}
|