Files
ScadaBridge/tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests/Actors/DataConnectionOpcUaFaultClassificationTests.cs
T
Joseph Doherty 513fa1aa16 docs(tests): fix CommentChecker findings across tests/ — 13,392 → 0 (repo-wide scan clean)
Comment/XML-doc changes only:
- add summaries to ~10k test methods, fixtures, fakes and helpers
  (+ <param> on theories, <returns> on async Task methods,
  <inheritdoc/> on interface implementations the checker can resolve)
- strip ~2.6k project-tracking references (WP*, P*-*, row-NN, Task N,
  #NN, Component-0NN) from comments, keeping the explanatory text;
  reword false positives in comments only
- real docs on fakes implementing BCL/library interfaces
  (IDisposable, ILogger, IOptionsMonitor, IAsyncLifetime)
- reword the last 5 src/ false positives (CWE-1236, failures-1,
  year-0001, M365)

Only non-comment edits: four one-line nested classes split across lines
so members can carry docs. Build 0 errors / 0 warnings.
2026-10-07 15:05:49 -04:00

110 lines
5.1 KiB
C#

using Akka.Actor;
using Akka.TestKit.Xunit2;
using NSubstitute;
using Opc.Ua;
using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol;
using ZB.MOM.WW.ScadaBridge.Commons.Messages.DataConnection;
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
using ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Actors;
using ZB.MOM.WW.ScadaBridge.HealthMonitoring;
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests.Actors;
/// <summary>
/// Classification half — how a thrown
/// <see cref="ServiceResultException"/> out of a batch subscribe is classified.
///
/// <para>
/// <b>The gap these pin.</b> <c>IsConnectionLevelFailure</c> knew only about
/// <c>InvalidOperationException</c> / socket / timeout / IO faults, so the OPC UA SDK's own way of
/// reporting a dead session — a <c>ServiceResultException</c> carrying a bad-session status —
/// was treated as a per-tag resolution failure for the WHOLE chunk. Every tag went unresolved and
/// the backoff probe re-issued the same batch against the same dead session forever, growing the
/// adapter's monitored-item bookkeeping each round, instead of reconnecting once.
/// </para>
///
/// <para>
/// The classification must stay narrow: a per-node status (<c>BadNodeIdUnknown</c>) is exactly the
/// "device still booting / wrong tag path" case the resolution timer exists for, and must NOT put
/// the connection into a reconnect loop.
/// </para>
/// </summary>
public class DataConnectionOpcUaFaultClassificationTests : TestKit
{
private readonly ISiteHealthCollector _health = Substitute.For<ISiteHealthCollector>();
private readonly IDataConnectionFactory _factory = Substitute.For<IDataConnectionFactory>();
private static DataConnectionOptions Options() => new()
{
ReconnectInterval = TimeSpan.FromMilliseconds(100),
TagResolutionRetryInterval = TimeSpan.FromMilliseconds(150),
TagResolutionRetryMaxInterval = TimeSpan.FromMilliseconds(600),
WriteTimeout = TimeSpan.FromSeconds(5),
SeedReadMaxAttempts = 1,
SeedReadRetryDelay = TimeSpan.FromMilliseconds(10),
SubscribeBatchSize = 5,
SubscribeBatchDelay = TimeSpan.FromMilliseconds(50),
SeedReadBatchSize = 4,
SeedReadMaxParallelism = 2,
SeedOverallTimeout = TimeSpan.FromSeconds(30),
QualityFlushInterval = TimeSpan.FromMilliseconds(200)
};
private IActorRef CreateActor(FakeBatchDataConnection adapter, string name) =>
Sys.ActorOf(Props.Create(() => new DataConnectionActor(
name, adapter, Options(), _health, _factory, "OpcUa")), name);
private int HealthTransitions(string connectionName, ConnectionHealth health) =>
_health.ReceivedCalls().Count(c =>
c.GetMethodInfo().Name == nameof(ISiteHealthCollector.UpdateConnectionHealth) &&
c.GetArguments() is [string name, ConnectionHealth reported, ..] &&
name == connectionName && reported == health);
/// <summary>
/// A bad-session fault is a CONNECTION fault: the request fails and the actor enters
/// Reconnecting (which pushes bad quality for the connection).
///
/// <para><b>Fails before the fix:</b> the chunk was treated per-tag, so the request was acked
/// Success and the connection stayed nominally up on a dead session.</para>
/// </summary>
[Fact]
public void BadSessionServiceResultException_IsConnectionLevel_AndDrivesReconnect()
{
const string name = "opcua-bad-session";
var adapter = new FakeBatchDataConnection
{
BatchSubscribeThrows = () =>
new ServiceResultException(StatusCodes.BadSessionIdInvalid, "session is no longer valid")
};
var actor = CreateActor(adapter, name);
actor.Tell(new SubscribeTagsRequest("c1", "inst1", name, ["tag1", "tag2"], DateTimeOffset.UtcNow));
ExpectMsg<SubscribeTagsResponse>(m => !m.Success && m.ErrorMessage != null, TimeSpan.FromSeconds(5));
ExpectMsg<ConnectionQualityChanged>(q => q.Quality == QualityCode.Bad, TimeSpan.FromSeconds(5));
}
/// <summary>
/// The narrowness control. <c>BadNodeIdUnknown</c> is a per-node fault: the tags go unresolved
/// (bad quality, retried on the backoff timer) and the connection is NOT torn down.
/// </summary>
[Fact]
public void BadNodeIdServiceResultException_StaysPerTag_AndDoesNotTearDownTheConnection()
{
const string name = "opcua-bad-nodeid";
var adapter = new FakeBatchDataConnection
{
BatchSubscribeThrows = () =>
new ServiceResultException(StatusCodes.BadNodeIdUnknown, "no such node")
};
var actor = CreateActor(adapter, name);
actor.Tell(new SubscribeTagsRequest("c1", "inst1", name, ["tag1", "tag2"], DateTimeOffset.UtcNow));
// Per-tag treatment: bad quality per tag, and the request itself is still acked Success
// (the tags are registered and retried, exactly as an unresolved tag path is).
FishForMessage<SubscribeTagsResponse>(m => m.Success, TimeSpan.FromSeconds(5));
Assert.Equal(0, HealthTransitions(name, ConnectionHealth.Disconnected));
}
}