/// <summary>
/// In-memory state for a single site's health, stored by the central aggregator.
/// Immutable: every state transition produces a new instance which the aggregator
/// installs into its <c>ConcurrentDictionary</c> via an atomic compare-and-swap.
/// This makes handing the reference straight to UI callers safe — a consumer can
/// never observe a torn or half-applied update.
/// </summary>
public sealed record SiteHealthState
{
public required string SiteId { get; init; }
/// <summary>
/// The latest full <see cref="SiteHealthReport"/> received for the site, or
/// <c>null</c> if the site is known only via heartbeats and has not yet sent
/// a report.
/// </summary>
public SiteHealthReport? LatestReport { get; init; }
/// <summary>
/// Time the latest full <see cref="SiteHealthReport"/> was processed.
/// Used by the UI to surface report staleness during failover.
/// </summary>
public DateTimeOffset LastReportReceivedAt { get; init; }
/// <summary>
/// Time the most recent signal of any kind (full report OR heartbeat) was
/// received. Drives offline detection — heartbeats from the standby keep the
/// site marked online even when the active node is unable to produce a report
/// (mid-failover, brief stalls). Heartbeat cadence is owned by the Cluster
/// Infrastructure / SiteCommunicationActor (every
/// CommunicationOptions.TransportHeartbeatInterval — 5s by default).
/// </summary>
public DateTimeOffset LastHeartbeatAt { get; init; }
public long LastSequenceNumber { get; init; }
public bool IsOnline { get; init; }
}