using Akka.Actor;
using Microsoft.CodeAnalysis.Scripting;
using Microsoft.Extensions.DependencyInjection;
using Microsoft.Extensions.Logging;
using ZB.MOM.WW.ScadaBridge.Commons.Messages.Streaming;
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
using ZB.MOM.WW.ScadaBridge.Commons.Types.Flattening;
using ZB.MOM.WW.ScadaBridge.HealthMonitoring;
using ZB.MOM.WW.ScadaBridge.SiteEventLogging;
using ZB.MOM.WW.ScadaBridge.SiteRuntime.Scripts;
using System.Globalization;
using System.Text.Json;
namespace ZB.MOM.WW.ScadaBridge.SiteRuntime.Actors;
/// <summary>
/// WP-16: Alarm Actor — coordinator actor, child of Instance Actor, peer to Script Actors.
/// Subscribes to attribute change notifications from Instance Actor.
///
/// Evaluates alarm conditions:
/// - ValueMatch: attribute equals a specific value
/// - RangeViolation: attribute outside min/max range
/// - RateOfChange: attribute rate exceeds threshold (configurable window, default per-second)
///
/// State (active/normal) is in memory only, NOT persisted.
/// On restart: starts normal, re-evaluates from incoming values.
///
/// WP-21: AlarmExecutionActor CAN call Instance.CallScript() (ask to sibling Script Actor).
/// Instance scripts CANNOT call alarm on-trigger scripts (no Instance.CallAlarmScript API).
///
/// Supervision: Resume on exception; AlarmExecutionActor stopped on exception.
/// </summary>
public class AlarmActor : ReceiveActor
{
private readonly string _alarmName;
private readonly string _instanceName;
private readonly IActorRef _instanceActor;
private readonly SharedScriptLibrary _sharedScriptLibrary;
private readonly SiteRuntimeOptions _options;
private readonly ILogger _logger;
private readonly ISiteHealthCollector? _healthCollector;
private readonly IServiceProvider? _serviceProvider;
/// <summary>
/// M1.5: the optional site operational-event log, resolved once from
/// <see cref="_serviceProvider"/> at construction and cached. The
/// registration is process-lifetime (a singleton), so resolving once on
/// the actor's own thread is both correct and cheaper than a per-event
/// <c>GetService</c> on the hot path. <c>null</c> when no provider was
/// supplied (the test/no-logging path) — <see cref="LogAlarmEvent"/> then
/// no-ops.
/// </summary>
private readonly ISiteEventLogger? _siteEventLogger;
/// <summary>
/// M1.5: priority at or above which a computed-alarm raise is logged as
/// <c>Error</c> to the site event log; below it, raises log as <c>Warning</c>.
/// Mirrors the 01000 alarm-severity scale.
/// </summary>
private const int ErrorPriorityThreshold = 700;
private AlarmState _currentState = AlarmState.Normal;
/// <summary>
/// Always <see cref="AlarmLevel.None"/> for binary trigger types. For
/// <see cref="AlarmTriggerType.HiLo"/> this is the source of truth — the
/// state machine transitions when the computed level changes.
/// </summary>
private AlarmLevel _currentLevel = AlarmLevel.None;
private readonly AlarmTriggerType _triggerType;
private readonly AlarmEvalConfig _evalConfig;
private readonly int _priority;
private readonly string? _onTriggerScriptName;
private readonly Script<object?>? _onTriggerCompiledScript;
// Expression trigger: compiled expression + the attribute snapshot it
// evaluates against. This field is the single home for the compiled
// expression on the hot path.
private readonly Script<object?>? _compiledTriggerExpression;
private readonly Dictionary<string, object?> _attributeSnapshot = new();
/// <summary>
/// SiteRuntime-017: the exact dictionary instance this actor was seeded from
/// at construction. The Instance Actor must pass a private snapshot here, not
/// its live <c>_attributes</c> field. Exposed for regression coverage of that
/// isolation contract.
/// </summary>
internal IReadOnlyDictionary<string, object?>? SeedAttributesReference { get; }
// Rate of change tracking
private readonly Queue<(DateTimeOffset Timestamp, double Value)> _rateOfChangeWindow = new();
private readonly TimeSpan _rateOfChangeWindowDuration;
private int _executionCounter;
/// <summary>Initializes a new <see cref="AlarmActor"/> and configures message handlers for the alarm.</summary>
/// <param name="alarmName">The canonical name of this alarm.</param>
/// <param name="instanceName">The name of the owning instance.</param>
/// <param name="instanceActor">Reference to the parent instance actor used for attribute access and script calls.</param>
/// <param name="alarmConfig">The resolved alarm configuration including trigger type, priority, and script references.</param>
/// <param name="onTriggerCompiledScript">Pre-compiled on-trigger script, or <c>null</c> if no script is defined.</param>
/// <param name="sharedScriptLibrary">Shared script library providing common utilities to executed scripts.</param>
/// <param name="options">Site runtime configuration options.</param>
/// <param name="logger">Logger for alarm diagnostics.</param>
/// <param name="compiledTriggerExpression">Pre-compiled trigger expression, or <c>null</c> for non-expression triggers.</param>
/// <param name="initialAttributes">Seed attribute snapshot so static attributes evaluate correctly at startup.</param>
/// <param name="healthCollector">Optional health collector for surfacing alarm execution metrics.</param>
/// <param name="serviceProvider">Optional DI service provider used to resolve the optional
/// <see cref="ISiteEventLogger"/> for M1.5 <c>alarm</c> operational events. Fire-and-forget;
/// a logging failure never affects alarm evaluation.</param>
public AlarmActor(
string alarmName,
string instanceName,
IActorRef instanceActor,
ResolvedAlarm alarmConfig,
Script<object?>? onTriggerCompiledScript,
SharedScriptLibrary sharedScriptLibrary,
SiteRuntimeOptions options,
ILogger logger,
Script<object?>? compiledTriggerExpression = null,
IReadOnlyDictionary<string, object?>? initialAttributes = null,
ISiteHealthCollector? healthCollector = null,
IServiceProvider? serviceProvider = null)
{
_alarmName = alarmName;
_instanceName = instanceName;
_instanceActor = instanceActor;
_sharedScriptLibrary = sharedScriptLibrary;
_options = options;
_logger = logger;
_healthCollector = healthCollector;
_serviceProvider = serviceProvider;
// M1.5: resolve the optional site event logger once and cache it,
// rather than calling GetService on every alarm transition.
_siteEventLogger = serviceProvider?.GetService<ISiteEventLogger>();
_priority = alarmConfig.PriorityLevel;
_onTriggerScriptName = alarmConfig.OnTriggerScriptCanonicalName;
_onTriggerCompiledScript = onTriggerCompiledScript;
_compiledTriggerExpression = compiledTriggerExpression;
// Seed the trigger-expression attribute snapshot from the instance's
// initial attribute set so static attributes (which never re-emit an
// AttributeValueChanged after deploy) evaluate correctly at startup.
SeedAttributesReference = initialAttributes;
if (initialAttributes != null)
{
foreach (var kvp in initialAttributes)
_attributeSnapshot[kvp.Key] = kvp.Value;
}
// Parse trigger type
_triggerType = Enum.TryParse<AlarmTriggerType>(alarmConfig.TriggerType, true, out var tt)
? tt : AlarmTriggerType.ValueMatch;
_evalConfig = ParseEvalConfig(alarmConfig.TriggerConfiguration);
_rateOfChangeWindowDuration = _evalConfig is RateOfChangeEvalConfig roc
? roc.WindowDuration
: TimeSpan.FromSeconds(1);
// Handle attribute value changes
Receive<AttributeValueChanged>(HandleAttributeValueChanged);
// Handle alarm execution completion
Receive<AlarmExecutionCompleted>(_ =>
_logger.LogDebug("Alarm {Alarm} execution completed on {Instance}", _alarmName, _instanceName));
}
/// <inheritdoc />
protected override void PreStart()
{
base.PreStart();
_logger.LogInformation(
"AlarmActor {Alarm} started on instance {Instance}, trigger={TriggerType}",
_alarmName, _instanceName, _triggerType);
}
/// <inheritdoc />
protected override SupervisorStrategy SupervisorStrategy()
{
return new OneForOneStrategy(
maxNrOfRetries: -1,
withinTimeRange: TimeSpan.FromMinutes(1),
decider: Decider.From(ex =>
{
_logger.LogWarning(ex,
"AlarmExecutionActor for {Alarm} on {Instance} failed, stopping",
_alarmName, _instanceName);
return Directive.Stop;
}));
}
/// <summary>
/// Evaluates alarm condition on attribute change. Alarm evaluation errors are logged,
/// actor continues (does not crash).
/// </summary>
private void HandleAttributeValueChanged(AttributeValueChanged changed)
{
// Expression triggers evaluate against a snapshot of every attribute,
// not a single monitored attribute. Keep the snapshot current for every
// change before the IsMonitoredAttribute gate (which does not apply).
if (_triggerType == AlarmTriggerType.Expression)
{
_attributeSnapshot[changed.AttributeName] = changed.Value;
}
else if (!IsMonitoredAttribute(changed.AttributeName))
{
// Only evaluate if this change is for an attribute we're monitoring
return;
}
try
{
if (_triggerType == AlarmTriggerType.HiLo)
{
HandleHiLoTransition(EvaluateHiLo(changed.Value));
return;
}
var isTriggered = _triggerType switch
{
AlarmTriggerType.ValueMatch => EvaluateValueMatch(changed.Value),
AlarmTriggerType.RangeViolation => EvaluateRangeViolation(changed.Value),
AlarmTriggerType.RateOfChange => EvaluateRateOfChange(changed.Value, changed.Timestamp),
AlarmTriggerType.Expression => EvaluateExpression(),
_ => false
};
if (isTriggered && _currentState == AlarmState.Normal)
{
// Transition: Normal → Active
_currentState = AlarmState.Active;
_logger.LogInformation(
"Alarm {Alarm} ACTIVATED on instance {Instance}",
_alarmName, _instanceName);
// Notify Instance Actor of alarm state change
var alarmChanged = new AlarmStateChanged(
_instanceName, _alarmName, AlarmState.Active, _priority, DateTimeOffset.UtcNow);
_instanceActor.Tell(alarmChanged);
// M1.5: operational `alarm` event — raise. Severity by priority.
LogAlarmEvent(RaiseSeverity(_priority), $"Alarm {_alarmName} activated (priority {_priority})");
// Spawn AlarmExecutionActor if on-trigger script defined
if (_onTriggerCompiledScript != null)
{
SpawnAlarmExecution(AlarmLevel.None, _priority, string.Empty);
}
}
else if (!isTriggered && _currentState == AlarmState.Active)
{
// Transition: Active → Normal (no script on clear)
_currentState = AlarmState.Normal;
_logger.LogInformation(
"Alarm {Alarm} CLEARED on instance {Instance}",
_alarmName, _instanceName);
var alarmChanged = new AlarmStateChanged(
_instanceName, _alarmName, AlarmState.Normal, _priority, DateTimeOffset.UtcNow);
_instanceActor.Tell(alarmChanged);
// M1.5: operational `alarm` event — return to normal.
LogAlarmEvent("Info", $"Alarm {_alarmName} cleared");
}
}
catch (Exception ex)
{
_healthCollector?.IncrementAlarmError();
// Alarm evaluation errors logged, actor continues
_logger.LogError(ex,
"Alarm {Alarm} evaluation error on {Instance}",
_alarmName, _instanceName);
}
}
/// <summary>
/// HiLo state machine: emit an AlarmStateChanged whenever the evaluated
/// level changes. Spawns the on-trigger script only on the Normal→Active
/// edge (i.e., when entering an alarm band from the normal band) — not on
/// level escalations like Hi→HiHi or Low→LowLow.
/// </summary>
private void HandleHiLoTransition(AlarmLevel newLevel)
{
if (newLevel == _currentLevel) return;
var previousLevel = _currentLevel;
_currentLevel = newLevel;
_currentState = newLevel == AlarmLevel.None ? AlarmState.Normal : AlarmState.Active;
var priority = LevelPriority(newLevel);
var message = LevelMessage(newLevel);
_logger.LogInformation(
"Alarm {Alarm} on {Instance} transitioned {Prev} → {New} (priority={Priority})",
_alarmName, _instanceName, previousLevel, newLevel, priority);
var alarmChanged = new AlarmStateChanged(
_instanceName, _alarmName, _currentState, priority, DateTimeOffset.UtcNow)
{
Level = newLevel,
Message = message
};
_instanceActor.Tell(alarmChanged);
// M1.5: operational `alarm` event. Entering a band from Normal is a raise
// (severity by the band's priority); returning to None is a clear; a
// level-to-level escalation/de-escalation is an informational transition.
if (newLevel == AlarmLevel.None)
{
LogAlarmEvent("Info", $"Alarm {_alarmName} cleared ({previousLevel} → Normal)");
}
else if (previousLevel == AlarmLevel.None)
{
LogAlarmEvent(RaiseSeverity(priority),
$"Alarm {_alarmName} activated at {newLevel} (priority {priority})");
}
else
{
LogAlarmEvent("Info",
$"Alarm {_alarmName} transitioned {previousLevel} → {newLevel} (priority {priority})");
}
if (previousLevel == AlarmLevel.None
&& newLevel != AlarmLevel.None
&& _onTriggerCompiledScript != null)
{
SpawnAlarmExecution(newLevel, priority, message);
}
}
/// <summary>
/// M1.5: maps an alarm priority (01000) to a site-event severity for a
/// <i>raise</i> transition — <c>Error</c> at or above
/// <see cref="ErrorPriorityThreshold"/>, otherwise <c>Warning</c>. Clears and
/// inter-band transitions always log as <c>Info</c>.
/// </summary>
private static string RaiseSeverity(int priority) =>
priority >= ErrorPriorityThreshold ? "Error" : "Warning";
/// <summary>
/// M1.5: fire-and-forget an <c>alarm</c> operational event to the optional
/// <see cref="ISiteEventLogger"/> (resolved once at construction and cached
/// in <see cref="_siteEventLogger"/>). Never awaited so a logging failure
/// cannot affect alarm evaluation (matching the established
/// ScriptActor/ScriptExecutionActor pattern).
/// </summary>
private void LogAlarmEvent(string severity, string message)
{
_ = _siteEventLogger?.LogEventAsync(
"alarm", severity, _instanceName, $"AlarmActor:{_alarmName}", message);
}
/// <summary>
/// Returns the per-setpoint priority for the given level. Falls back to
/// the alarm-level <see cref="_priority"/> when the HiLo config did not
/// override the priority for that band, or for <see cref="AlarmLevel.None"/>.
/// </summary>
private int LevelPriority(AlarmLevel level)
{
if (_evalConfig is not HiLoEvalConfig hiLo) return _priority;
return level switch
{
AlarmLevel.LowLow => hiLo.LoLoPriority ?? _priority,
AlarmLevel.Low => hiLo.LoPriority ?? _priority,
AlarmLevel.High => hiLo.HiPriority ?? _priority,
AlarmLevel.HighHigh => hiLo.HiHiPriority ?? _priority,
_ => _priority
};
}
/// <summary>
/// Per-band operator message. Empty string when no message is configured
/// for the band, or for non-HiLo trigger types, or for the None level
/// (alarm clear).
/// </summary>
private string LevelMessage(AlarmLevel level)
{
if (_evalConfig is not HiLoEvalConfig hiLo) return string.Empty;
return level switch
{
AlarmLevel.LowLow => hiLo.LoLoMessage ?? string.Empty,
AlarmLevel.Low => hiLo.LoMessage ?? string.Empty,
AlarmLevel.High => hiLo.HiMessage ?? string.Empty,
AlarmLevel.HighHigh => hiLo.HiHiMessage ?? string.Empty,
_ => string.Empty
};
}
private bool IsMonitoredAttribute(string attributeName)
{
return _evalConfig.MonitoredAttributeName == attributeName;
}
private bool EvaluateValueMatch(object? value)
{
if (_evalConfig is not ValueMatchEvalConfig config) return false;
if (config.MatchValue == null) return value == null;
var valueStr = value?.ToString() ?? "";
// Support "!=X" for not-equal matching
if (config.MatchValue.StartsWith("!="))
{
var expected = config.MatchValue[2..];
return !string.Equals(valueStr, expected, StringComparison.Ordinal);
}
return string.Equals(valueStr, config.MatchValue, StringComparison.Ordinal);
}
private bool EvaluateRangeViolation(object? value)
{
if (_evalConfig is not RangeViolationEvalConfig config) return false;
if (value == null) return false;
try
{
// InvariantCulture so string attribute values parse consistently
// regardless of host locale (SiteRuntime-023).
var numericValue = Convert.ToDouble(value, CultureInfo.InvariantCulture);
return numericValue < config.Min || numericValue > config.Max;
}
catch
{
return false;
}
}
private bool EvaluateRateOfChange(object? value, DateTimeOffset timestamp)
{
if (_evalConfig is not RateOfChangeEvalConfig config) return false;
if (value == null) return false;
try
{
// InvariantCulture so string attribute values parse consistently
// regardless of host locale (SiteRuntime-023).
var numericValue = Convert.ToDouble(value, CultureInfo.InvariantCulture);
// Add to window
_rateOfChangeWindow.Enqueue((timestamp, numericValue));
// Remove old entries outside the window
var cutoff = timestamp - _rateOfChangeWindowDuration;
while (_rateOfChangeWindow.Count > 0 && _rateOfChangeWindow.Peek().Timestamp < cutoff)
{
_rateOfChangeWindow.Dequeue();
}
if (_rateOfChangeWindow.Count < 2) return false;
var oldest = _rateOfChangeWindow.Peek();
var timeDelta = (timestamp - oldest.Timestamp).TotalSeconds;
if (timeDelta <= 0) return false;
var signedRate = (numericValue - oldest.Value) / timeDelta;
return config.Direction switch
{
RateOfChangeDirection.Rising => signedRate > config.ThresholdPerSecond,
RateOfChangeDirection.Falling => -signedRate > config.ThresholdPerSecond,
_ => Math.Abs(signedRate) > config.ThresholdPerSecond
};
}
catch
{
return false;
}
}
/// <summary>
/// Evaluates the compiled trigger expression against the current attribute
/// snapshot, returning the resulting bool. This bool feeds the existing
/// binary Normal↔Active state path — the alarm is active while true. A
/// throwing, non-bool, or timed-out expression is treated as false (logged
/// as an alarm error) so that the state machine still runs — an Active
/// alarm correctly clears if the expression starts throwing.
/// </summary>
private bool EvaluateExpression()
{
if (_compiledTriggerExpression == null) return false;
try
{
var globals = new TriggerExpressionGlobals(_attributeSnapshot);
// Bound evaluation with a short timeout. The CancellationToken
// covers cooperative/async cases; a pathological CPU-bound
// expression is not fully interruptible. Acceptable because
// trigger expressions are authored by trusted Design-role users
// and are compile-checked pre-deployment.
using var cts = new CancellationTokenSource(TimeSpan.FromSeconds(2));
var state = _compiledTriggerExpression
.RunAsync(globals, cancellationToken: cts.Token)
.GetAwaiter().GetResult();
return state.ReturnValue is bool b && b;
}
catch (Exception ex)
{
// OperationCanceledException (timeout) falls through here too,
// and is correctly treated as false.
_healthCollector?.IncrementAlarmError();
_logger.LogError(ex,
"Alarm {Alarm} trigger expression evaluation failed on {Instance}; treated as false",
_alarmName, _instanceName);
return false;
}
}
/// <summary>
/// HiLo level evaluator: returns the most-severe matching band for the
/// given value. Severity order checked from highest to lowest so that a
/// value at exactly Hi==HiHi resolves to HighHigh. Unset setpoints (null)
/// are skipped, allowing partial configs (e.g., HighHigh only).
///
/// Hysteresis: when the alarm is already in a level whose threshold the
/// value would re-cross from inside, the threshold is relaxed by the
/// configured deadband. This prevents flapping at the boundary — once at
/// HighHigh with HiHi=100 and hiHiDeadband=5, the alarm stays HighHigh
/// until the value drops below 95.
/// </summary>
private AlarmLevel EvaluateHiLo(object? value)
{
if (_evalConfig is not HiLoEvalConfig config) return AlarmLevel.None;
if (value == null) return _currentLevel;
double numericValue;
// InvariantCulture so string attribute values parse consistently
// regardless of host locale (SiteRuntime-023).
try { numericValue = Convert.ToDouble(value, CultureInfo.InvariantCulture); }
catch { return _currentLevel; }
// When the current level is at-or-above HighHigh, relax the HiHi exit.
// Same for the other directions.
var hiHiThreshold = config.HiHi;
if (hiHiThreshold is { } hh && _currentLevel == AlarmLevel.HighHigh)
hiHiThreshold = hh - Math.Max(0, config.HiHiDeadband ?? 0);
var hiThreshold = config.Hi;
if (hiThreshold is { } h && (_currentLevel == AlarmLevel.High || _currentLevel == AlarmLevel.HighHigh))
hiThreshold = h - Math.Max(0, config.HiDeadband ?? 0);
var loLoThreshold = config.LoLo;
if (loLoThreshold is { } ll && _currentLevel == AlarmLevel.LowLow)
loLoThreshold = ll + Math.Max(0, config.LoLoDeadband ?? 0);
var loThreshold = config.Lo;
if (loThreshold is { } l && (_currentLevel == AlarmLevel.Low || _currentLevel == AlarmLevel.LowLow))
loThreshold = l + Math.Max(0, config.LoDeadband ?? 0);
if (hiHiThreshold is { } effHiHi && numericValue >= effHiHi) return AlarmLevel.HighHigh;
if (hiThreshold is { } effHi && numericValue >= effHi) return AlarmLevel.High;
if (loLoThreshold is { } effLoLo && numericValue <= effLoLo) return AlarmLevel.LowLow;
if (loThreshold is { } effLo && numericValue <= effLo) return AlarmLevel.Low;
return AlarmLevel.None;
}
/// <summary>
/// Spawns an AlarmExecutionActor to run the on-trigger script.
/// Passes the firing alarm's level/priority/message so the script can
/// branch on severity via the <c>Alarm</c> global.
/// </summary>
private void SpawnAlarmExecution(AlarmLevel level, int priority, string message)
{
if (_onTriggerCompiledScript == null) return;
var executionId = $"{_alarmName}-alarm-exec-{_executionCounter++}";
// SiteRuntime-009: the on-trigger script body runs on the dedicated
// ScriptExecutionScheduler, not the shared .NET thread pool.
var props = Props.Create(() => new AlarmExecutionActor(
_alarmName,
_instanceName,
level,
priority,
message,
_onTriggerCompiledScript,
_instanceActor,
_sharedScriptLibrary,
_options,
_logger));
Context.ActorOf(props, executionId);
}
private AlarmEvalConfig ParseEvalConfig(string? triggerConfigJson)
{
if (string.IsNullOrEmpty(triggerConfigJson))
return new ValueMatchEvalConfig("", null);
try
{
var doc = JsonDocument.Parse(triggerConfigJson);
var root = doc.RootElement;
// Support both "attributeName" and "attribute" keys
var attr = root.TryGetProperty("attributeName", out var attrEl)
? attrEl.GetString() ?? ""
: root.TryGetProperty("attribute", out var attrEl2)
? attrEl2.GetString() ?? ""
: "";
return _triggerType switch
{
AlarmTriggerType.ValueMatch => new ValueMatchEvalConfig(
attr,
root.TryGetProperty("matchValue", out var mv) ? mv.GetString()
: root.TryGetProperty("value", out var mv2) ? mv2.GetString()
: null),
AlarmTriggerType.RangeViolation => new RangeViolationEvalConfig(
attr,
root.TryGetProperty("min", out var minEl) ? minEl.GetDouble()
: root.TryGetProperty("low", out var lowEl) ? lowEl.GetDouble()
: double.MinValue,
root.TryGetProperty("max", out var maxEl) ? maxEl.GetDouble()
: root.TryGetProperty("high", out var highEl) ? highEl.GetDouble()
: double.MaxValue),
AlarmTriggerType.RateOfChange => new RateOfChangeEvalConfig(
attr,
root.TryGetProperty("thresholdPerSecond", out var tps) ? tps.GetDouble() : 10.0,
root.TryGetProperty("windowSeconds", out var ws)
? TimeSpan.FromSeconds(ws.GetDouble())
: TimeSpan.FromSeconds(1),
root.TryGetProperty("direction", out var dirEl)
? ParseDirection(dirEl.GetString())
: RateOfChangeDirection.Either),
AlarmTriggerType.HiLo => new HiLoEvalConfig(
attr,
LoLo: TryReadDouble(root, "loLo"),
Lo: TryReadDouble(root, "lo"),
Hi: TryReadDouble(root, "hi"),
HiHi: TryReadDouble(root, "hiHi"),
LoLoPriority: TryReadInt(root, "loLoPriority"),
LoPriority: TryReadInt(root, "loPriority"),
HiPriority: TryReadInt(root, "hiPriority"),
HiHiPriority: TryReadInt(root, "hiHiPriority"),
LoLoDeadband: TryReadDouble(root, "loLoDeadband"),
LoDeadband: TryReadDouble(root, "loDeadband"),
HiDeadband: TryReadDouble(root, "hiDeadband"),
HiHiDeadband: TryReadDouble(root, "hiHiDeadband"),
LoLoMessage: TryReadString(root, "loLoMessage"),
LoMessage: TryReadString(root, "loMessage"),
HiMessage: TryReadString(root, "hiMessage"),
HiHiMessage: TryReadString(root, "hiHiMessage")),
// Expression triggers have no single monitored attribute; they
// evaluate the compiled expression (passed into the actor and
// cached in _compiledTriggerExpression) over the full attribute
// snapshot. MonitoredAttributeName is unused.
AlarmTriggerType.Expression => new ExpressionEvalConfig(
"",
TriggerExpressionGlobals.ExtractExpression(triggerConfigJson) ?? ""),
_ => new ValueMatchEvalConfig(attr, null)
};
}
catch (Exception ex)
{
_logger.LogWarning(ex, "Failed to parse alarm trigger config for {Alarm}", _alarmName);
return new ValueMatchEvalConfig("", null);
}
}
private static RateOfChangeDirection ParseDirection(string? raw) => raw?.ToLowerInvariant() switch
{
"rising" or "up" or "positive" => RateOfChangeDirection.Rising,
"falling" or "down" or "negative" => RateOfChangeDirection.Falling,
_ => RateOfChangeDirection.Either
};
private static double? TryReadDouble(JsonElement el, string name)
{
if (!el.TryGetProperty(name, out var p)) return null;
return p.ValueKind switch
{
JsonValueKind.Number => p.GetDouble(),
JsonValueKind.String when double.TryParse(p.GetString(), System.Globalization.NumberStyles.Float, System.Globalization.CultureInfo.InvariantCulture, out var v) => v,
_ => null
};
}
private static int? TryReadInt(JsonElement el, string name)
{
if (!el.TryGetProperty(name, out var p)) return null;
return p.ValueKind switch
{
JsonValueKind.Number when p.TryGetInt32(out var i) => i,
JsonValueKind.Number => (int)p.GetDouble(),
JsonValueKind.String when int.TryParse(p.GetString(), System.Globalization.NumberStyles.Integer, System.Globalization.CultureInfo.InvariantCulture, out var v) => v,
_ => null
};
}
private static string? TryReadString(JsonElement el, string name)
{
if (!el.TryGetProperty(name, out var p)) return null;
return p.ValueKind == JsonValueKind.String ? p.GetString() : null;
}
// ── Internal messages ──
internal record AlarmExecutionCompleted(string AlarmName, bool Success);
}
internal enum RateOfChangeDirection { Either, Rising, Falling }
// ── Alarm evaluation config types ──
internal abstract record AlarmEvalConfig(string MonitoredAttributeName);
internal record ValueMatchEvalConfig(string MonitoredAttributeName, string? MatchValue) : AlarmEvalConfig(MonitoredAttributeName);
internal record RangeViolationEvalConfig(string MonitoredAttributeName, double Min, double Max) : AlarmEvalConfig(MonitoredAttributeName);
internal record RateOfChangeEvalConfig(
string MonitoredAttributeName,
double ThresholdPerSecond,
TimeSpan WindowDuration,
RateOfChangeDirection Direction) : AlarmEvalConfig(MonitoredAttributeName);
/// <summary>
/// Expression evaluation config: a read-only boolean C# expression evaluated
/// over the full attribute snapshot. Has no single monitored attribute
/// (<see cref="AlarmEvalConfig.MonitoredAttributeName"/> is empty). The
/// compiled expression itself lives on the actor's <c>_compiledTriggerExpression</c>
/// field, the single source for the hot path.
/// </summary>
internal record ExpressionEvalConfig(
string MonitoredAttributeName,
string Expression) : AlarmEvalConfig(MonitoredAttributeName);
/// <summary>
/// HiLo evaluation config: any subset of the four setpoints may be set; null
/// means "don't evaluate that band". Per-setpoint priorities override the
/// alarm-level priority for AlarmStateChanged messages emitted for that band.
/// </summary>
internal record HiLoEvalConfig(
string MonitoredAttributeName,
double? LoLo,
double? Lo,
double? Hi,
double? HiHi,
int? LoLoPriority,
int? LoPriority,
int? HiPriority,
int? HiHiPriority,
double? LoLoDeadband = null,
double? LoDeadband = null,
double? HiDeadband = null,
double? HiHiDeadband = null,
string? LoLoMessage = null,
string? LoMessage = null,
string? HiMessage = null,
string? HiHiMessage = null) : AlarmEvalConfig(MonitoredAttributeName);