Joseph Doherty 0ffd4bdbea docs(src): fix CommentChecker findings across src/ — 1,032 → 5 (all false positives)
Comment/XML-doc changes only, no code logic:
- strip project-tracking references (WP*, P*-*, row-NN, #NN, Task N) from
  comments, keeping the explanatory rationale
- add missing summaries, <param>, <returns>, <typeparam> and <inheritdoc/>
- replace misused <inheritdoc/> with real docs; where <inheritdoc/> was
  combined with useful remarks, move the rationale into // comments
- drop stale replicationActor <param> on DeploymentManagerActor ctor

Remaining 5 are false positives (CWE-1236 x2, failures-1, year-0001, M365).
Build 0 errors / 0 warnings.
2026-10-07 14:12:25 -04:00

79 lines
3.2 KiB
C#

using Microsoft.Extensions.Hosting;
using Microsoft.Extensions.Logging;
using ZB.MOM.WW.ScadaBridge.HealthMonitoring;
namespace ZB.MOM.WW.ScadaBridge.SiteRuntime.Streaming;
/// <summary>
/// Site-side
/// hosted service that periodically reads <see cref="SiteStreamManager.AlarmPublishDroppedCount"/>
/// and pushes it into <see cref="ISiteHealthCollector.SetSiteStreamAlarmDropCount"/> so
/// the next <see cref="ISiteHealthCollector.CollectReport"/> carries a fresh snapshot on
/// the site health report. Mirrors <c>ScriptSchedulerStatsReporter</c>: immediate first
/// probe, fixed cadence, exceptions logged and swallowed so the loop survives every probe
/// failure.
/// </summary>
public sealed class SiteStreamAlarmDropReporter : BackgroundService
{
/// <summary>Default poll cadence (10 s) — coarse enough to amortise across health reports.</summary>
internal static readonly TimeSpan DefaultPollInterval = TimeSpan.FromSeconds(10);
private readonly ISiteHealthCollector _collector;
private readonly SiteStreamManager _streamManager;
private readonly ILogger<SiteStreamAlarmDropReporter> _logger;
private readonly TimeSpan _pollInterval;
/// <summary>Initializes a new instance of <see cref="SiteStreamAlarmDropReporter"/>.</summary>
/// <param name="collector">The site health collector that receives the drop count.</param>
/// <param name="streamManager">The site stream manager whose alarm-queue drop count is sampled.</param>
/// <param name="logger">Logger instance.</param>
/// <param name="pollInterval">Poll interval override; defaults to <see cref="DefaultPollInterval"/> (10 s).</param>
public SiteStreamAlarmDropReporter(
ISiteHealthCollector collector,
SiteStreamManager streamManager,
ILogger<SiteStreamAlarmDropReporter> logger,
TimeSpan? pollInterval = null)
{
_collector = collector ?? throw new ArgumentNullException(nameof(collector));
_streamManager = streamManager ?? throw new ArgumentNullException(nameof(streamManager));
_logger = logger ?? throw new ArgumentNullException(nameof(logger));
_pollInterval = pollInterval ?? DefaultPollInterval;
}
/// <inheritdoc />
protected override async Task ExecuteAsync(CancellationToken stoppingToken)
{
// Immediate first probe so the first health report after start carries a
// real snapshot instead of a zero.
Probe();
while (!stoppingToken.IsCancellationRequested)
{
try
{
await Task.Delay(_pollInterval, stoppingToken).ConfigureAwait(false);
}
catch (OperationCanceledException)
{
break;
}
Probe();
}
}
private void Probe()
{
try
{
_collector.SetSiteStreamAlarmDropCount(_streamManager.AlarmPublishDroppedCount);
}
catch (Exception ex)
{
// Catch-all is deliberate: the hosted service must survive every class
// of probe failure so the next tick gets a chance.
_logger.LogWarning(ex, "SiteStreamAlarmDropReporter probe failed; next tick will retry.");
}
}
}