using ZB.MOM.WW.Configuration; namespace ZB.MOM.WW.ScadaBridge.SiteRuntime; /// /// Validates at startup. These values size the /// staggered Instance-Actor startup batches, the dedicated script-execution thread /// pool, and the site-wide Akka stream's per-subscriber buffer; a zero or negative /// count either creates a degenerate thread scheduler / stream stage or trips an /// deep inside actor construction with an /// opaque message that never names the offending config key. Registered with /// ValidateOnStart() so a bad ScadaBridge:SiteRuntime section fails /// fast at boot with a clear, key-naming message. /// public sealed class SiteRuntimeOptionsValidator : OptionsValidatorBase { /// protected override void Validate(ValidationBuilder builder, SiteRuntimeOptions options) { builder.RequireThat(options.StartupBatchSize > 0, $"ScadaBridge:SiteRuntime:StartupBatchSize must be greater than 0 " + $"(was {options.StartupBatchSize}); it sizes each staggered Instance-Actor startup batch."); builder.RequireThat(options.StartupBatchDelayMs >= 0, $"ScadaBridge:SiteRuntime:StartupBatchDelayMs must be >= 0 " + $"(was {options.StartupBatchDelayMs}); it is the inter-batch startup delay."); builder.RequireThat(options.MaxScriptCallDepth > 0, $"ScadaBridge:SiteRuntime:MaxScriptCallDepth must be greater than 0 " + $"(was {options.MaxScriptCallDepth}); it bounds recursive CallScript/CallShared depth."); builder.RequireThat(options.ScriptExecutionTimeoutSeconds > 0, $"ScadaBridge:SiteRuntime:ScriptExecutionTimeoutSeconds must be greater than 0 " + $"(was {options.ScriptExecutionTimeoutSeconds})."); builder.RequireThat(options.StreamBufferSize > 0, $"ScadaBridge:SiteRuntime:StreamBufferSize must be greater than 0 " + $"(was {options.StreamBufferSize}); it is the per-subscriber site-stream buffer size."); builder.RequireThat(options.ScriptExecutionThreadCount > 0, $"ScadaBridge:SiteRuntime:ScriptExecutionThreadCount must be greater than 0 " + $"(was {options.ScriptExecutionThreadCount}); it is the FLOOR for the dedicated script-execution scheduler."); builder.RequireThat(options.ScriptExecutionMaxThreadCount >= options.ScriptExecutionThreadCount, $"ScadaBridge:SiteRuntime:ScriptExecutionMaxThreadCount must be >= ScriptExecutionThreadCount " + $"(was {options.ScriptExecutionMaxThreadCount} vs {options.ScriptExecutionThreadCount}); it is the " + "CEILING for the instance-scaled script-execution pool and a ceiling below the floor would " + "silently shrink the configured pool."); builder.RequireThat(options.TriggerEvalMaxConcurrency > 0, $"ScadaBridge:SiteRuntime:TriggerEvalMaxConcurrency must be greater than 0 " + $"(was {options.TriggerEvalMaxConcurrency}); it gates concurrent trigger-expression evaluations " + "and a zero gate would park every Expression trigger on the node forever."); builder.RequireThat(options.TriggerEvalTimeoutSeconds > 0, $"ScadaBridge:SiteRuntime:TriggerEvalTimeoutSeconds must be greater than 0 " + $"(was {options.TriggerEvalTimeoutSeconds}); it bounds a single trigger-expression evaluation " + "(measured from enqueue, so it also bounds gate-wait time)."); builder.RequireThat(options.MaxConcurrentRunsPerScript > 0, $"ScadaBridge:SiteRuntime:MaxConcurrentRunsPerScript must be greater than 0 " + $"(was {options.MaxConcurrentRunsPerScript}); it caps concurrent runs per script and a zero cap " + "would shed every trigger."); builder.RequireThat(options.MirroredAlarmCapPerSource > 0, $"ScadaBridge:SiteRuntime:MirroredAlarmCapPerSource must be greater than 0 " + $"(was {options.MirroredAlarmCapPerSource})."); builder.RequireThat(options.NativeAlarmRetryIntervalMs > 0, $"ScadaBridge:SiteRuntime:NativeAlarmRetryIntervalMs must be greater than 0 " + $"(was {options.NativeAlarmRetryIntervalMs})."); builder.RequireThat(options.ConfigFetchTimeoutSeconds > 0, $"ScadaBridge:SiteRuntime:ConfigFetchTimeoutSeconds must be greater than 0 " + $"(was {options.ConfigFetchTimeoutSeconds})."); builder.RequireThat(options.TagSubscribeRetryIntervalMs > 0, $"ScadaBridge:SiteRuntime:TagSubscribeRetryIntervalMs must be greater than 0 " + $"(was {options.TagSubscribeRetryIntervalMs}); a zero interval hot-loops the tag-subscribe " + "retry and a negative one throws inside the Instance Actor's retry scheduling."); builder.RequireThat(options.TagSubscribeRetryMaxIntervalMs >= options.TagSubscribeRetryIntervalMs, $"ScadaBridge:SiteRuntime:TagSubscribeRetryMaxIntervalMs must be >= TagSubscribeRetryIntervalMs " + $"(was {options.TagSubscribeRetryMaxIntervalMs} vs {options.TagSubscribeRetryIntervalMs}); " + "it is the ceiling of the tag-subscribe retry backoff."); builder.RequireThat(options.TagSubscribeInFlightCeilingMs > 0, $"ScadaBridge:SiteRuntime:TagSubscribeInFlightCeilingMs must be greater than 0 " + $"(was {options.TagSubscribeInFlightCeilingMs}); it bounds how long an unanswered tag-subscribe " + "blocks a duplicate for the same connection."); builder.RequireThat(options.StuckScriptGraceMs >= 0, $"ScadaBridge:SiteRuntime:StuckScriptGraceMs must be >= 0 " + $"(was {options.StuckScriptGraceMs}); a negative grace throws inside the stuck-script watchdog's delay."); builder.RequireThat(options.AlarmPublishQueueCapacity > 0, $"ScadaBridge:SiteRuntime:AlarmPublishQueueCapacity must be greater than 0 " + $"(was {options.AlarmPublishQueueCapacity}); it bounds SiteStreamManager's dedicated alarm publish queue."); builder.RequireThat(options.ScriptRunSummaryIntervalSeconds >= 0, $"ScadaBridge:SiteRuntime:ScriptRunSummaryIntervalSeconds must be >= 0 " + $"(was {options.ScriptRunSummaryIntervalSeconds}); it is the ScriptRunSummaryRecorder " + "flush interval and a negative value throws inside its delay. 0 disables the flush."); builder.RequireThat(options.InstanceSweepIntervalSeconds >= 0, $"ScadaBridge:SiteRuntime:InstanceSweepIntervalSeconds must be >= 0 " + $"(was {options.InstanceSweepIntervalSeconds}); it is the Deployment Manager's " + "instance reconcile-sweep interval and a negative value throws inside the Akka timer. " + "0 disables the sweep, which reopens the replication-seeded-config and stale-revision " + "self-heals (deferred register rows 78 and 72)."); builder.RequireThat(options.TraceArmWindowSeconds > 0, $"ScadaBridge:SiteRuntime:TraceArmWindowSeconds must be greater than 0 " + $"(was {options.TraceArmWindowSeconds}); it is how long the Instance Actor waits for the " + "device echo of a Flow Debugger traced write before the arm expires (design 2026-09-05 ยง5.3)."); builder.RequireThat(options.MaxLogLinesPerRun > 0, $"ScadaBridge:SiteRuntime:MaxLogLinesPerRun must be greater than 0 " + $"(was {options.MaxLogLinesPerRun}); it is the per-run cap on Flow Debugger ScriptLog " + "rows a script's Log.* calls may produce (design 2026-09-09 D7), and a run that may " + "emit no lines at all cannot report its own truncation."); } }