pair=central mode=active action=kill active=scadabridge-central-a victim=scadabridge-central-a survivor=scadabridge-central-b hit at 2026-11-13T02:23:11Z Active kill: waiting for scadabridge-central-b to take over as the active node (victim stays down; budget ~25s + hand-over)... survivor logged the Down at +26s PASS: scadabridge-central-b took over as active in 26s with the victim still down (downed the dead oldest, assumed Oldest, re-hosted the singletons). Confirming Traefik routes to the new active node... Traefik routing recovered 28s after the hit. Recovering scadabridge-central-a (kill -> start)... Waiting for the victim to rejoin as a ready standby (scadabridge-central-a /health/ready)... Recovered: scadabridge-central-a is ready as standby (rejoined) 2s after recovery. Checking for a lingering dual-active (10 samples, 1s apart)... Exactly one active node in 10/10 samples. Survivor downing/singleton evidence (last 20 matching log lines from scadabridge-central-b): [02:23:22 WRN] [Central/scadabridge-central-b] [leader-auto-down] akka.tcp://scadabridge@scadabridge-central-a:8081 is unreachable; it will be downed if still unreachable after 00:00:15 (this node akka.tcp://scadabridge@scadabridge-central-b:8081 is leader: False) [02:23:22 INF] [Central/scadabridge-central-b] [leader-auto-down] akka.tcp://scadabridge@scadabridge-central-b:8081 gained leadership (leader is now akka.tcp://scadabridge@scadabridge-central-b:8081); pending unreachable=[] [02:23:37 WRN] [Central/scadabridge-central-b] [leader-auto-down] DOWNING akka.tcp://scadabridge@scadabridge-central-a:8081: unreachable for 00:00:15 and this node (akka.tcp://scadabridge@scadabridge-central-b:8081) is leader [02:23:37 INF] [Central/scadabridge-central-b] Cluster Node [akka.tcp://scadabridge@scadabridge-central-b:8081] - Marking unreachable node [akka.tcp://scadabridge@scadabridge-central-a:8081] as [Down] [02:23:40 INF] [Central/scadabridge-central-b] [leader-auto-down] akka.tcp://scadabridge@scadabridge-central-b:8081 lost leadership (leader is now akka.tcp://scadabridge@scadabridge-central-a:8081); pending unreachable=[] SUMMARY pair=central mode=active action=kill down_logged_s=26 rejoin_s=2 Drill complete. Verify on the Health dashboard / Overview that both nodes show Up and exactly one is Primary. --- shut-out lines since hit (scadabridge-central-b, scadabridge-central-a)