using Microsoft.Extensions.Options;
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests;
///
/// Regression: intervals/timeouts drive the
/// DCL reconnect/tag-resolution timers and the seed-read retry loop; a
/// zero/negative duration (or a non-positive SeedReadMaxAttempts) must be
/// rejected at startup by an with a
/// clear, key-naming message rather than surfacing later at runtime.
///
public class DataConnectionOptionsValidatorTests
{
private static ValidateOptionsResult Validate(DataConnectionOptions options) =>
new DataConnectionOptionsValidator().Validate(Options.DefaultName, options);
/// Verifies that the default options are valid.
[Fact]
public void DefaultOptions_AreValid()
{
var result = Validate(new DataConnectionOptions());
Assert.True(result.Succeeded, result.FailureMessage);
}
/// Verifies that a zero reconnect interval is rejected.
[Fact]
public void ZeroReconnectInterval_IsRejected()
{
var result = Validate(new DataConnectionOptions { ReconnectInterval = TimeSpan.Zero });
Assert.True(result.Failed);
Assert.Contains("ReconnectInterval", result.FailureMessage);
}
/// Verifies that a non-positive seed-read max attempts value is rejected.
[Fact]
public void NonPositiveSeedReadMaxAttempts_IsRejected()
{
var result = Validate(new DataConnectionOptions { SeedReadMaxAttempts = 0 });
Assert.True(result.Failed);
Assert.Contains("SeedReadMaxAttempts", result.FailureMessage);
}
}