Compare commits

...

9 Commits

Author SHA1 Message Date
Joseph Doherty 73ce2e4d0f docs(secured-writes): mark plan tasks complete (build+tests+smoke) 2026-06-27 14:07:25 -04:00
Joseph Doherty c6a32e8fef test(central-ui): cover tree-select path for OnNodeSelected DataType 2026-06-27 13:48:58 -04:00
Joseph Doherty 63273fd0f8 feat(central-ui): tag selector + data-type auto-fill on Secured Writes 2026-06-27 13:38:52 -04:00
Joseph Doherty 1ad19e28f6 feat(central-ui): NodeBrowserDialog emits full node + optional ShowSearch
Fully suppress search UI (box + results panel) when ShowSearch=false, and
reset search state on ShowAsync so a reused dialog never shows stale results.
2026-06-27 13:36:50 -04:00
Joseph Doherty 265f115a1f feat(central-ui): add Galaxy-type to DataType mapper for secured writes 2026-06-27 13:27:32 -04:00
Joseph Doherty c4daf941d2 docs: secured-writes tag selector + MxGateway browse DataType 2026-06-27 13:24:26 -04:00
Joseph Doherty ce4d5f0639 feat(dcl): surface MxGateway attribute DataType through browse seam 2026-06-27 13:24:25 -04:00
Joseph Doherty 5076f0a277 docs(secured-writes): implementation plan + task persistence 2026-06-27 12:09:49 -04:00
Joseph Doherty 0bbe637370 docs(secured-writes): design — tag selector + data-type auto-fill from MxGateway browse 2026-06-27 12:04:12 -04:00
14 changed files with 1003 additions and 16 deletions
@@ -0,0 +1,171 @@
# Secured Writes — Tag Selector + Data-Type Auto-Fill (Design)
**Date:** 2026-06-27
**Component(s):** Central UI (#9), Data Connection Layer (#4); Security & Auth (#10) for the Secured Writes UX.
**Status:** Approved design — ready for implementation plan.
## Problem
On the Central UI Secured Writes page (`/operations/secured-writes`), an Operator submits a
two-person MxGateway secured write. Today the **Tag path** is a free-text input and the **Data
type** is a manually-chosen dropdown defaulting to `Boolean`. Operators must know the exact
MxGateway tag reference and the correct data type by hand — error-prone, and a wrong data type
only surfaces at *approval* time (the value can't be decoded/written).
We want:
1. The **Tag path** field to be backed by a **tag selector** (browse the connection's tags).
2. The **Data type** to be **auto-selected from the chosen tag**.
## Key insight — the data type is already available
Secured writes are **MxGateway-only** (the page filters connections to `Protocol == "MxGateway"`,
and the ManagementActor enforces the same on submit). The MxGateway gateway *already returns* a
per-attribute `data_type_name` (free-form Galaxy text, e.g. `"Float"`, `"Integer"`, `"Boolean"`)
on its browse response (`GalaxyAttribute.data_type_name` in `galaxy_repository.proto`). ScadaBridge
currently **discards** it: `RealMxGatewayClient.BrowseChildrenAsync` reads only
`FullTagReference` + `AttributeName` when building `MxBrowseChild`.
So the feature is mostly *plumbing an existing value through* + reusing the existing
`NodeBrowserDialog`. No new gRPC, no DB/schema/migration, no new cross-cluster message contracts.
Reused as-is:
- `NodeBrowserDialog` / `TreeRow` tag browser (already used by `InstanceConfigure`,
`TestBindingsDialog`).
- The full browse call path: `IBrowseService` → `CommunicationService.BrowseNodeAsync` →
`SiteCommunicationActor` → `DeploymentManager` → `DataConnectionManagerActor` →
`DataConnectionActor` → adapter.
- `BrowseNode` already carries an optional `DataType` field.
## UX decisions (confirmed)
- **Tag field:** editable text field **+ a "Browse…" button** (hybrid, matching
`InstanceConfigure`). Operators can still paste a known reference; the browser populates the field.
- **Data type:** **auto-filled from the tag but left editable**. The Galaxy type name is free-form;
the map to ScadaBridge's `DataType` enum is best-effort, so an unmapped type must leave the
operator able to choose.
## Design
### Layer 1 — Surface `DataType` from MxGateway browse (DCL)
- `Adapters/IMxGatewayClient.cs`: extend the seam record additively —
`record MxBrowseChild(string NodeId, string DisplayName, BrowseNodeClass NodeClass, bool HasChildren, string? DataType = null)`.
- `Adapters/RealMxGatewayClient.cs` (`BrowseChildrenAsync`): when projecting
`parentObject.Attributes`, pass `attr.DataTypeName` (normalise empty → `null`) into `MxBrowseChild`.
- `Adapters/MxGatewayDataConnection.cs`: forward it —
`new BrowseNode(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren, DataType: c.DataType)`.
- Test fake `FakeMxGatewayClient`: update to the new record shape and emit a sample `DataType` so
tests can assert end-to-end surfacing.
`ValueRank`/`Writable` remain `null` for MxGateway (not needed here). Array attributes
(`is_array`/`array_dimension`) are **explicitly out of scope** — a secured write to an array via
this form is an edge case; the operator can pick `List` manually.
### Layer 2 — Let the browser emit the full node (shared dialog)
`NodeBrowserDialog` currently emits only `OnSelected(string nodeId)`. Add, additively:
- `EventCallback<BrowseNode> OnNodeSelected` — invoked alongside the existing `OnSelected` in
`SelectBrowseNode()`. The internal tree node retains its source `BrowseNode` so the emit is
faithful (NodeId + DataType). Existing callers are unaffected (the callback is optional).
- `bool ShowSearch = true` — set `false` from Secured Writes. MxGateway does **not** implement
`IAddressSpaceSearchable`, so the search box would always return a `NotBrowsable` failure;
hiding it avoids a guaranteed-broken affordance. Default `true` keeps OPC UA callers unchanged.
### Layer 3 — Wire the form (`Components/Pages/Operations/SecuredWrites.razor`)
- Tag path becomes an input-group: the existing editable `<input>` + a `Browse…` button,
`disabled` unless a site **and** an MxGateway connection are selected
(`CanBrowse`, mirroring `InstanceConfigure`'s `canBrowse`).
- Render one `<NodeBrowserDialog @ref="_browserRef" SiteId="@_formSiteIdentifier"
ConnectionName="@_formConnectionName" ShowSearch="false" OnNodeSelected="OnTagPicked" />`.
- `OpenBrowser()` → `await _browserRef.ShowAsync(_formSiteIdentifier, _formConnectionName, _formTagPath)`
(seeds with whatever is already typed).
- `OnTagPicked(BrowseNode node)`:
```csharp
_formTagPath = node.NodeId;
if (SecuredWriteDataTypeMapper.TryMap(node.DataType, out var dt))
_formValueType = dt.ToString();
// else: leave _formValueType unchanged — operator picks
```
- The Data type `<select>` is unchanged (no `disabled`): pre-filled but editable. `CanSubmit`
is unchanged.
### Layer 4 — Galaxy type → `DataType` mapping
A small internal, unit-testable static class in CentralUI. Case-insensitive, whitespace-trimmed:
| Galaxy `data_type_name` | ScadaBridge `DataType` |
| --- | --- |
| `boolean`, `bool` | `Boolean` |
| `integer`, `int`, `int32` | `Int32` |
| `float` | `Float` |
| `double` | `Double` |
| `string` | `String` |
| `time` | `DateTime` |
| anything else / null / empty | *no map — operator's selection kept* |
```csharp
internal static class SecuredWriteDataTypeMapper
{
public static bool TryMap(string? galaxyTypeName, out DataType dataType)
{
dataType = default;
if (string.IsNullOrWhiteSpace(galaxyTypeName)) return false;
switch (galaxyTypeName.Trim().ToLowerInvariant())
{
case "boolean": case "bool": dataType = DataType.Boolean; return true;
case "integer": case "int": case "int32": dataType = DataType.Int32; return true;
case "float": dataType = DataType.Float; return true;
case "double": dataType = DataType.Double; return true;
case "string": dataType = DataType.String; return true;
case "time": dataType = DataType.DateTime; return true;
default: return false;
}
}
}
```
`Binary` and `List` are intentionally not auto-mapped (no clean Galaxy source); operator picks them.
## Error handling / edge cases
- Browse button disabled until site + MxGateway connection chosen.
- Gateway returns no type (older gateway / read gap) → `DataType` null → mapper returns false →
dropdown keeps its value; operator picks. Graceful.
- Unmapped Galaxy type → same graceful fallback; auto-fill stays editable so a mis-map is fixable.
- MxGateway search box hidden (`ShowSearch=false`) — tree browse + expand only.
## Testing
- **Unit:** `SecuredWriteDataTypeMapper` — every known name (incl. casing/whitespace) → expected
enum; `null` / `""` / exotic → `false`.
- **DCL:** assert a browsed MxGateway attribute's `DataTypeName` survives to `BrowseNode.DataType`
through `MxGatewayDataConnection` (via the updated `FakeMxGatewayClient`).
- **Build + targeted tests** for touched projects (DCL, DCL tests, CentralUI) — not the full suite.
- **Live-smoke:** rebuild the image (`bash docker/deploy.sh`) and exercise the page against an
MxGateway connection.
## Docs to update (spec travels with code)
- Secured Writes section under **Security & Auth** — tag selector + data-type auto-fill UX.
- MxGateway browse **type-info** note under **Data Connection Layer** — `DataType` now surfaced
for MxGateway (previously OPC-UA-only).
## Out of scope
- Array attribute handling (`is_array`) → `List`.
- OPC UA / non-MxGateway connections (Secured Writes is MxGateway-only).
- MxGateway address-space search (adapter does not implement `IAddressSpaceSearchable`).
- Any DB schema, migration, or new message contract (`ValueType` already exists on
`SubmitSecuredWriteCommand`).
## Files touched
- `src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/IMxGatewayClient.cs`
- `src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/RealMxGatewayClient.cs`
- `src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/MxGatewayDataConnection.cs`
- `FakeMxGatewayClient` (DCL test fake)
- `src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Dialogs/NodeBrowserDialog.razor`
- `src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Pages/Operations/SecuredWrites.razor`
- new `SecuredWriteDataTypeMapper` + unit test
- Component design docs (Security & Auth, Data Connection Layer)
@@ -0,0 +1,553 @@
# Secured Writes — Tag Selector + Data-Type Auto-Fill Implementation Plan
> **For Claude:** REQUIRED SUB-SKILL: Use superpowers-extended-cc:executing-plans to implement this plan task-by-task.
**Goal:** On `/operations/secured-writes`, back the Tag path with the existing tag browser and auto-fill the Data type from the selected MxGateway tag.
**Architecture:** Plumb the MxGateway gateway's already-returned per-attribute `data_type_name` through the DCL browse seam into `BrowseNode.DataType` (currently dropped); make the shared `NodeBrowserDialog` emit the full selected node additively; wire a Browse button + a best-effort Galaxy-type→`DataType` mapper into the page. No new gRPC, DB/schema/migration, or message contracts.
**Tech Stack:** C#/.NET, Akka.NET (untouched here), Blazor Server (Bootstrap), bUnit + xUnit + NSubstitute for tests.
**Design doc:** `docs/plans/2026-06-27-secured-writes-tag-selector-design.md`
---
## Task ordering & parallelism
- **Tasks 1, 2, 3, 5** are mutually independent (different files) — dispatchable in parallel.
- **Task 4** depends on Tasks 1, 2, 3 (needs the dialog callback, the mapper, and the surfaced DataType).
- **Task 6** (verify) depends on everything.
---
### Task 1: Surface `DataType` through the MxGateway browse seam (DCL)
**Classification:** standard
**Estimated implement time:** ~4 min
**Parallelizable with:** Task 2, Task 3, Task 5
**Files:**
- Modify: `src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/IMxGatewayClient.cs:21`
- Modify: `src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/RealMxGatewayClient.cs:263-270`
- Modify: `src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/MxGatewayDataConnection.cs:269-271`
- Test: `tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests/Adapters/MxGatewayDataConnectionTests.cs` (add one test after line 246)
**Step 1: Write the failing test**
Add after the existing `BrowseChildrenAsync_maps_children_and_truncated` test (after line 246) in `MxGatewayDataConnectionTests.cs`:
```csharp
[Fact]
public async Task BrowseChildrenAsync_surfaces_attribute_datatype()
{
var fake = new FakeMxGatewayClient
{
BrowseHandler = _ => (new List<MxBrowseChild>
{
new("Area1.Pump.Speed", "Speed", BrowseNodeClass.Variable, false, "Double"),
}, false)
};
var adapter = NewAdapter(fake);
await adapter.ConnectAsync(Details());
var result = await adapter.BrowseChildrenAsync(null);
Assert.Equal("Double", result.Children[0].DataType);
}
```
**Step 2: Run test to verify it fails**
Run: `dotnet test tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests --filter "FullyQualifiedName~BrowseChildrenAsync_surfaces_attribute_datatype"`
Expected: FAIL — compile error (the 5-arg `MxBrowseChild` ctor does not exist yet).
**Step 3: Write minimal implementation**
(a) `IMxGatewayClient.cs:21` — add the additive field:
```csharp
public record MxBrowseChild(string NodeId, string DisplayName, BrowseNodeClass NodeClass, bool HasChildren, string? DataType = null);
```
(b) `MxGatewayDataConnection.cs:269-271` — forward the new field:
```csharp
var nodes = children
.Select(c => new BrowseNode(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren, DataType: c.DataType))
.ToList();
```
(c) `RealMxGatewayClient.cs:265-270` — pass the gateway's Galaxy type name (empty → null) when projecting attributes:
```csharp
children.Add(new MxBrowseChild(
attr.FullTagReference,
attr.AttributeName,
BrowseNodeClass.Variable,
false,
string.IsNullOrEmpty(attr.DataTypeName) ? null : attr.DataTypeName));
```
(The object loop at lines 252-256 is left unchanged — objects are not leaves and carry no type.)
**Step 4: Run test to verify it passes**
Run: `dotnet test tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests --filter "FullyQualifiedName~BrowseChildrenAsync"`
Expected: PASS (both the new test and the existing `_maps_children_and_truncated`, whose 4-arg ctors stay valid because `DataType` defaults to null).
**Step 5: Commit**
```bash
git add src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/IMxGatewayClient.cs \
src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/RealMxGatewayClient.cs \
src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/Adapters/MxGatewayDataConnection.cs \
tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests/Adapters/MxGatewayDataConnectionTests.cs
git commit -m "feat(dcl): surface MxGateway attribute DataType through browse seam"
```
---
### Task 2: Galaxy-type → `DataType` mapper (CentralUI)
**Classification:** small
**Estimated implement time:** ~4 min
**Parallelizable with:** Task 1, Task 3, Task 5
**Files:**
- Create: `src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Pages/Operations/SecuredWriteDataTypeMapper.cs`
- Test: `tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests/Components/SecuredWriteDataTypeMapperTests.cs` (create)
**Step 1: Write the failing test**
Create `tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests/Components/SecuredWriteDataTypeMapperTests.cs`:
```csharp
using ZB.MOM.WW.ScadaBridge.CentralUI.Components.Pages.Operations;
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
namespace ZB.MOM.WW.ScadaBridge.CentralUI.Tests.Components;
public class SecuredWriteDataTypeMapperTests
{
[Theory]
[InlineData("Boolean", DataType.Boolean)]
[InlineData("bool", DataType.Boolean)]
[InlineData("Integer", DataType.Int32)]
[InlineData("int", DataType.Int32)]
[InlineData("Int32", DataType.Int32)]
[InlineData("Float", DataType.Float)]
[InlineData("Double", DataType.Double)]
[InlineData("String", DataType.String)]
[InlineData("Time", DataType.DateTime)]
[InlineData(" double ", DataType.Double)] // trimmed + case-insensitive
public void TryMap_known_galaxy_types_map(string galaxy, DataType expected)
{
Assert.True(SecuredWriteDataTypeMapper.TryMap(galaxy, out var dt));
Assert.Equal(expected, dt);
}
[Theory]
[InlineData(null)]
[InlineData("")]
[InlineData(" ")]
[InlineData("ElapsedTime")]
[InlineData("SomeVendorType")]
public void TryMap_unknown_or_blank_returns_false(string? galaxy)
{
Assert.False(SecuredWriteDataTypeMapper.TryMap(galaxy, out _));
}
}
```
**Step 2: Run test to verify it fails**
Run: `dotnet test tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests --filter "FullyQualifiedName~SecuredWriteDataTypeMapperTests"`
Expected: FAIL — compile error (`SecuredWriteDataTypeMapper` does not exist).
**Step 3: Write minimal implementation**
Create `src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Pages/Operations/SecuredWriteDataTypeMapper.cs`:
```csharp
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
namespace ZB.MOM.WW.ScadaBridge.CentralUI.Components.Pages.Operations;
/// <summary>
/// Best-effort map from the MxGateway/Galaxy free-form attribute type name
/// (<c>GalaxyAttribute.data_type_name</c>, surfaced on <c>BrowseNode.DataType</c>)
/// to a ScadaBridge <see cref="DataType"/>. Used by the Secured Writes page to
/// pre-fill the data-type dropdown when a tag is picked. Unknown or blank names
/// return false so the operator's existing selection is left untouched. Galaxy
/// type names are free-form text, not a stable enum — keep this tolerant.
/// </summary>
internal static class SecuredWriteDataTypeMapper
{
public static bool TryMap(string? galaxyTypeName, out DataType dataType)
{
dataType = default;
if (string.IsNullOrWhiteSpace(galaxyTypeName)) return false;
switch (galaxyTypeName.Trim().ToLowerInvariant())
{
case "boolean": case "bool": dataType = DataType.Boolean; return true;
case "integer": case "int": case "int32": dataType = DataType.Int32; return true;
case "float": dataType = DataType.Float; return true;
case "double": dataType = DataType.Double; return true;
case "string": dataType = DataType.String; return true;
case "time": dataType = DataType.DateTime; return true;
default: return false;
}
}
}
```
**Step 4: Run test to verify it passes**
Run: `dotnet test tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests --filter "FullyQualifiedName~SecuredWriteDataTypeMapperTests"`
Expected: PASS (14 cases).
**Step 5: Commit**
```bash
git add src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Pages/Operations/SecuredWriteDataTypeMapper.cs \
tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests/Components/SecuredWriteDataTypeMapperTests.cs
git commit -m "feat(central-ui): add Galaxy-type to DataType mapper for secured writes"
```
---
### Task 3: `NodeBrowserDialog` — additive `OnNodeSelected` + `ShowSearch` (CentralUI)
**Classification:** standard
**Estimated implement time:** ~5 min
**Parallelizable with:** Task 1, Task 2, Task 5
**Files:**
- Modify: `src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Dialogs/NodeBrowserDialog.razor` (params, search-box gate, selected-node tracking, Confirm emit)
- Test: `tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests/Components/NodeBrowserDialogSelectionTests.cs` (create)
**Background (do not skip):** Selection is confirmed in `Confirm()` (the footer "Select" button), which fires `OnSelected(_selectedNodeId)`. `Select`/`SelectBrowseNode`/`UseManual` only set `_selectedNodeId`. So the new `OnNodeSelected` must fire from `Confirm()`, and the dialog must track the selected node (for its `DataType`).
**Step 1: Write the failing test**
Create `tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests/Components/NodeBrowserDialogSelectionTests.cs` (mirrors the existing `NodeBrowserDialogSearchTests` harness; reuses the search path to select a typed node):
```csharp
using Bunit;
using Microsoft.AspNetCore.Components;
using Microsoft.Extensions.DependencyInjection;
using NSubstitute;
using ZB.MOM.WW.ScadaBridge.CentralUI.Components.Dialogs;
using ZB.MOM.WW.ScadaBridge.CentralUI.Services;
using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol;
using ZB.MOM.WW.ScadaBridge.Commons.Messages.Management;
namespace ZB.MOM.WW.ScadaBridge.CentralUI.Tests.Components;
public class NodeBrowserDialogSelectionTests : BunitContext
{
private readonly IBrowseService _browse = Substitute.For<IBrowseService>();
public NodeBrowserDialogSelectionTests()
{
Services.AddSingleton(_browse);
_browse.BrowseChildrenAsync(
Arg.Any<string>(), Arg.Any<string>(), Arg.Any<string?>(),
Arg.Any<string?>(), Arg.Any<CancellationToken>())
.Returns(new BrowseNodeResult(Array.Empty<BrowseNode>(), Truncated: false, Failure: null));
_browse.SearchAsync(
Arg.Any<string>(), Arg.Any<string>(), Arg.Any<string>(),
Arg.Any<int>(), Arg.Any<int>(), Arg.Any<CancellationToken>())
.Returns(new SearchAddressSpaceResult(
Matches: new[]
{
new AddressSpaceMatch(
new BrowseNode("ns=2;s=Pump1.Speed", "Speed", BrowseNodeClass.Variable, HasChildren: false, DataType: "Double"),
Path: "Devices/Pump1/Speed"),
},
CapReached: false, Failure: null));
}
[Fact]
public void Confirm_emits_full_node_with_datatype_on_OnNodeSelected()
{
BrowseNode? captured = null;
var cut = Render<NodeBrowserDialog>(p => p
.Add(c => c.SiteId, "plant-a")
.Add(c => c.ConnectionName, "PLC-OPC")
.Add(c => c.OnNodeSelected, EventCallback.Factory.Create<BrowseNode>(this, n => captured = n)));
cut.InvokeAsync(() => cut.Instance.ShowAsync("plant-a", "PLC-OPC", null));
cut.Render();
cut.Find("[data-test=node-search-input]").Input("Pump1");
cut.Find("[data-test=node-search-button]").Click();
cut.FindAll("[data-test=node-search-result] a")[0].Click();
cut.Find(".modal-footer .btn-primary").Click();
Assert.NotNull(captured);
Assert.Equal("ns=2;s=Pump1.Speed", captured!.NodeId);
Assert.Equal("Double", captured.DataType);
}
[Fact]
public void ShowSearch_false_hides_search_box()
{
var cut = Render<NodeBrowserDialog>(p => p
.Add(c => c.SiteId, "plant-a")
.Add(c => c.ConnectionName, "PLC-MX")
.Add(c => c.ShowSearch, false));
cut.InvokeAsync(() => cut.Instance.ShowAsync("plant-a", "PLC-MX", null));
cut.Render();
Assert.Empty(cut.FindAll("[data-test=node-search-input]"));
}
}
```
**Step 2: Run test to verify it fails**
Run: `dotnet test tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests --filter "FullyQualifiedName~NodeBrowserDialogSelectionTests"`
Expected: FAIL — `OnNodeSelected` / `ShowSearch` parameters do not exist yet (compile error).
**Step 3: Write minimal implementation** — edit `NodeBrowserDialog.razor`:
(a) Gate the search input-group. Wrap lines 25-31 (the `<div class="input-group mb-3">…</div>` containing `node-search-input`/`node-search-button`) in:
```razor
@if (ShowSearch)
{
<div class="input-group mb-3">
<input class="form-control" data-test="node-search-input"
@bind="_searchQuery" @bind:event="oninput"
@onkeydown="SearchOnEnter"
placeholder="Search the address space by name or path…" />
<button class="btn btn-outline-primary" data-test="node-search-button" @onclick="SearchAsync">Search</button>
</div>
}
```
(b) Add parameters after line 114 (`[Parameter] public EventCallback OnCancelled …`):
```csharp
/// <summary>Additive: receives the full selected <see cref="BrowseNode"/> (incl.
/// DataType) on confirm, alongside the existing string-id <see cref="OnSelected"/>.
/// Optional — existing callers that only wire OnSelected are unaffected.</summary>
[Parameter] public EventCallback<BrowseNode> OnNodeSelected { get; set; }
/// <summary>When false, hides the address-space search box. Set false for protocols
/// that don't implement IAddressSpaceSearchable (e.g. MxGateway), where search would
/// always fail. Default true preserves OPC UA behaviour.</summary>
[Parameter] public bool ShowSearch { get; set; } = true;
```
(c) Add a tracking field next to `_selectedNodeId` (after line 117):
```csharp
private BrowseNode? _selectedNode;
```
(d) `TreeNode` — add a source reference (after the `DataType` property, ~line 149):
```csharp
/// <summary>The originating BrowseNode, retained so selection can emit the
/// full node (incl. DataType) via OnNodeSelected.</summary>
public BrowseNode? Source { get; init; }
```
(e) `ToTreeNode` (lines 197-198) — capture the source:
```csharp
private static TreeNode ToTreeNode(BrowseNode c) =>
new(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren) { DataType = c.DataType, Source = c };
```
(f) `ShowAsync` — reset the tracker. After `_selectedNodeId = initialNodeId;` (line 176) add:
```csharp
_selectedNode = null;
```
(g) `SelectBrowseNode` (line 309-314) — track the node. After `_manualNodeId = node.NodeId;` add:
```csharp
_selectedNode = node;
```
(h) `Select` (line 316-321) — track via the tree node's source. After `_manualNodeId = node.NodeId;` add:
```csharp
_selectedNode = node.Source;
```
(i) `UseManual` (line 349-352) — manual entry has no known type. After `_selectedNodeId = _manualNodeId.Trim();` add:
```csharp
_selectedNode = null;
```
(j) `Confirm` (lines 354-359) — also emit the full node:
```csharp
private async Task Confirm()
{
_isVisible = false;
if (!string.IsNullOrWhiteSpace(_selectedNodeId))
{
await OnSelected.InvokeAsync(_selectedNodeId!);
if (OnNodeSelected.HasDelegate)
await OnNodeSelected.InvokeAsync(
_selectedNode ?? new BrowseNode(_selectedNodeId!, _selectedNodeId!, BrowseNodeClass.Variable, HasChildren: false));
}
}
```
**Step 4: Run test to verify it passes**
Run: `dotnet test tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests --filter "FullyQualifiedName~NodeBrowserDialog"`
Expected: PASS — both the new `NodeBrowserDialogSelectionTests` and the existing `NodeBrowserDialogSearchTests` (search box still present by default; OnSelected still fires).
**Step 5: Commit**
```bash
git add src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Dialogs/NodeBrowserDialog.razor \
tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests/Components/NodeBrowserDialogSelectionTests.cs
git commit -m "feat(central-ui): NodeBrowserDialog emits full node + optional ShowSearch"
```
---
### Task 4: Wire the Browse button + data-type auto-fill into the page (CentralUI)
**Classification:** standard
**Estimated implement time:** ~5 min
**Parallelizable with:** none
**Depends on:** Task 1, Task 2, Task 3
**Files:**
- Modify: `src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Pages/Operations/SecuredWrites.razor`
No new automated test: the auto-fill logic is unit-tested in Task 2 and the dialog emit in Task 3; the page itself is gated behind `AuthorizeView`/policies with several injected services, so it is verified by build (this task) + live-smoke (Task 6). Do NOT add a heavyweight bUnit page harness.
**Step 1: Add usings** — after line 7 (`@using …Commons.Types.Enums`) add:
```razor
@using ZB.MOM.WW.ScadaBridge.CentralUI.Components.Dialogs
@using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol
```
**Step 2: Replace the Tag path field (lines 59-63)** with an input-group + Browse button:
```razor
<div class="col-md-4">
<label class="form-label form-label-sm">Tag path</label>
<div class="input-group input-group-sm">
<input class="form-control form-control-sm" @bind="_formTagPath"
placeholder="e.g. PLC1.Pump.Setpoint" data-test="secured-write-tagpath" />
<button class="btn btn-outline-secondary" type="button"
disabled="@(!CanBrowse)"
title="@(CanBrowse ? "Browse tags" : "Pick a site and MxGateway connection first")"
@onclick="OpenBrowser" data-test="secured-write-browse">Browse…</button>
</div>
</div>
```
**Step 3: Render the dialog once** — insert between line 91 (`</div>` closing the `mt-3` submit-button div) and line 92 (`</div>` closing `card-body`), inside the operator `Authorized` region:
```razor
<NodeBrowserDialog @ref="_browserRef"
SiteId="@_formSiteIdentifier"
ConnectionName="@_formConnectionName"
ShowSearch="false"
OnNodeSelected="OnTagPicked" />
```
**Step 4: Add the `@code` members** (place with the other submit-form fields, e.g. just after `_formComment` around line 227):
```csharp
private NodeBrowserDialog? _browserRef;
private bool CanBrowse =>
!string.IsNullOrWhiteSpace(_formSiteIdentifier)
&& !string.IsNullOrWhiteSpace(_formConnectionName);
private async Task OpenBrowser()
{
if (!CanBrowse || _browserRef is null) return;
await _browserRef.ShowAsync(_formSiteIdentifier, _formConnectionName, _formTagPath);
}
private void OnTagPicked(BrowseNode node)
{
_formTagPath = node.NodeId;
if (SecuredWriteDataTypeMapper.TryMap(node.DataType, out var dt))
_formValueType = dt.ToString();
}
```
(`SecuredWriteDataTypeMapper` is in the same `…Pages.Operations` namespace — no using needed.)
**Step 5: Build to verify it compiles**
Run: `dotnet build src/ZB.MOM.WW.ScadaBridge.CentralUI/ZB.MOM.WW.ScadaBridge.CentralUI.csproj`
Expected: Build succeeded, 0 errors.
**Step 6: Commit**
```bash
git add src/ZB.MOM.WW.ScadaBridge.CentralUI/Components/Pages/Operations/SecuredWrites.razor
git commit -m "feat(central-ui): tag selector + data-type auto-fill on Secured Writes"
```
---
### Task 5: Update component design docs
**Classification:** trivial
**Estimated implement time:** ~3 min
**Parallelizable with:** Task 1, Task 2, Task 3
**Files:**
- Modify: `docs/requirements/Component-Security.md` (Secured Writes section)
- Modify: `docs/requirements/Component-DataConnectionLayer.md` (MxGateway browse type-info)
**Step 1: Security doc.** Find the Secured Writes section: `grep -n "Secured Write" docs/requirements/Component-Security.md`. Add a concise sentence to the operator-submit description: the Tag path is backed by the shared tag browser (`NodeBrowserDialog`, search hidden for MxGateway), and the Data type is auto-filled (best-effort, still editable) from the selected tag's Galaxy type via `SecuredWriteDataTypeMapper`.
**Step 2: DCL doc.** Find the browse type-info note: `grep -n "DataType\|type-info\|BrowseNode\|MxGateway" docs/requirements/Component-DataConnectionLayer.md`. Update the type-info note so it states that `BrowseNode.DataType` is now surfaced for **MxGateway** too (from `GalaxyAttribute.data_type_name`), not OPC-UA-only. Note `ValueRank`/`Writable` remain OPC-UA-only.
**Step 3: Commit**
```bash
git add docs/requirements/Component-Security.md docs/requirements/Component-DataConnectionLayer.md
git commit -m "docs: secured-writes tag selector + MxGateway browse DataType"
```
---
### Task 6: Build, targeted tests, and live-smoke
**Classification:** standard
**Estimated implement time:** ~6 min (+ image rebuild)
**Parallelizable with:** none
**Depends on:** Task 1, Task 2, Task 3, Task 4, Task 5
**Step 1: Build the touched projects**
```bash
dotnet build src/ZB.MOM.WW.ScadaBridge.DataConnectionLayer/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.csproj
dotnet build src/ZB.MOM.WW.ScadaBridge.CentralUI/ZB.MOM.WW.ScadaBridge.CentralUI.csproj
```
Expected: Build succeeded, 0 errors.
**Step 2: Run targeted tests** (the touched test projects only — per the targeted-tests convention, not the full suite)
```bash
dotnet test tests/ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests --filter "FullyQualifiedName~MxGatewayDataConnectionTests"
dotnet test tests/ZB.MOM.WW.ScadaBridge.CentralUI.Tests --filter "FullyQualifiedName~SecuredWriteDataTypeMapperTests|FullyQualifiedName~NodeBrowserDialog"
```
Expected: all PASS.
**Step 3: Rebuild the cluster image and live-smoke**
```bash
bash docker/deploy.sh
```
Then in the browser (Traefik LB at `http://localhost:9000`), as a user holding the Operator role, open `/operations/secured-writes`:
- Pick a site + MxGateway connection → the **Browse…** button enables.
- Click Browse → the dialog opens with **no search box**; expand an object, pick an attribute → the Tag path fills with the tag reference and the Data type pre-selects the mapped type (still editable).
- Tag path remains hand-editable; Submit still works.
**Step 4: Final commit (if any smoke-fix needed)** — otherwise nothing to commit. Report results.
---
## Done criteria
- DCL test surfaces `BrowseNode.DataType` for MxGateway; existing browse test still green.
- Mapper unit tests green (known types map; unknown/blank → false).
- Dialog test: `OnNodeSelected` emits the typed node; `ShowSearch=false` hides search; existing dialog tests green.
- CentralUI + DCL build clean.
- Live-smoke: Browse populates tag path and auto-fills data type on an MxGateway connection.
- Design docs updated.
@@ -0,0 +1,12 @@
{
"planPath": "docs/plans/2026-06-27-secured-writes-tag-selector.md",
"tasks": [
{"id": 1, "subject": "Task 1: Surface DataType through MxGateway browse seam (DCL)", "status": "completed", "classification": "standard", "commit": "ce4d5f06"},
{"id": 2, "subject": "Task 2: Galaxy-type to DataType mapper (CentralUI)", "status": "completed", "classification": "small", "commit": "265f115a"},
{"id": 3, "subject": "Task 3: NodeBrowserDialog additive OnNodeSelected + ShowSearch (CentralUI)", "status": "completed", "classification": "standard", "commit": "1ad19e28", "followupTestCommit": "c6a32e8f"},
{"id": 4, "subject": "Task 4: Wire Browse button + data-type auto-fill into Secured Writes page", "status": "completed", "classification": "standard", "commit": "63273fd0", "blockedBy": [1, 2, 3]},
{"id": 5, "subject": "Task 5: Update component design docs", "status": "completed", "classification": "trivial", "commit": "c4daf941"},
{"id": 6, "subject": "Task 6: Build, targeted tests, live-smoke", "status": "completed", "classification": "standard", "blockedBy": [1, 2, 3, 4, 5], "note": "Build clean; DCL 13/13 + CentralUI 22/22; cluster healthy on branch image; page renders cleanly. Operator-gated Browse UI not live-smokeable locally (no Operator/Verifier user in test LDAP; no real MxGateway gateway in local infra)."}
],
"lastUpdated": "2026-06-27"
}
@@ -197,7 +197,7 @@ DCL is a clean data pipe on the hot path. Browse is an **opt-in capability** for
- `OpcUaDataConnection` and `MxGatewayDataConnection` both implement `IBrowsableDataConnection`; other/custom protocols do not (and return a `NotBrowsable` failure).
- `DataConnectionManagerActor` handles `BrowseNodeCommand` (fields: `ConnectionName`, `ParentNodeId`, and an optional opaque `ContinuationToken` for paging) and replies with `BrowseNodeResult` (children + `Truncated` + an optional continuation token + structured `BrowseFailure?`). The Central UI facade is `IBrowseService`/`BrowseService`, backing the `NodeBrowserDialog` tag picker.
- **Browse type-info** (OPC UA): each child `BrowseNode` carries optional best-effort type metadata — `DataType` (friendly name), `ValueRank` (scalar/array), and `Writable`. `RealOpcUaClient` batch-reads these attributes for **Variable** nodes during browse and maps built-in data-type node ids to friendly names; non-Variable rows leave them unset.
- **Browse type-info**: each child `BrowseNode` carries optional best-effort type metadata — `DataType` (friendly name), `ValueRank` (scalar/array), and `Writable`. `DataType` is populated by **both** OPC UA and MxGateway: `RealOpcUaClient` batch-reads built-in data-type node ids and maps them to friendly names for **Variable** nodes; `MxGatewayDataConnection` surfaces each attribute leaf's `GalaxyAttribute.data_type_name` (free-form Galaxy type text) as `DataType`. `ValueRank` and `Writable` are OPC-UA-only; MxGateway leaves them unset.
- Node ids are opaque protocol-specific strings: OPC UA uses NodeIds; MxGateway uses Galaxy gobject ids for navigable objects and full tag references for selectable attribute leaves.
- Browse runs against the live session; no caching at DCL.
- **Frame-size guard**: the reply crosses the site→central Akka frame (default 128 KB) on a temp Ask actor; an oversized reply is silently discarded by remoting, hanging the picker. The child handler caps each `BrowseNodeResult` to a byte budget (~100 KB) before replying, OR-ing the adapter's own truncation signal into `Truncated`. This is protocol-agnostic (every adapter's reply funnels through it). Per-protocol upstream caps narrow the window first: OPC UA requests at most 500 references per node (continuation point → `Truncated`); MxGateway relies on the gateway's `BrowseChildren` page cap.
+1 -1
View File
@@ -126,7 +126,7 @@ Set in a local or docker-dev environment via the environment variable `ScadaBrid
### Operator
- **Scope**: System-wide (always).
- **Permissions**:
- Submit a **secured write** to an MxAccess Gateway connection from the Central UI Secured Writes page (`/operations/secured-writes`) — the *initiating* half of the two-person write workflow.
- Submit a **secured write** to an MxAccess Gateway connection from the Central UI Secured Writes page (`/operations/secured-writes`) — the *initiating* half of the two-person write workflow. The **Tag path** is selected via the shared `NodeBrowserDialog` tag browser ("Browse…" button; the dialog's address-space search box is hidden for MxGateway connections, which have no search capability). The **Data type** is auto-filled best-effort from the selected tag's Galaxy data type via `SecuredWriteDataTypeMapper` and remains operator-editable.
- **Purpose**: One of the two distinct global roles backing MxGateway secured writes. An Operator initiates a write; it never executes until a separate **Verifier** approves it. Holding Operator alone never executes a write.
### Verifier
@@ -22,15 +22,18 @@
</div>
}
<div class="input-group mb-3">
<input class="form-control" data-test="node-search-input"
@bind="_searchQuery" @bind:event="oninput"
@onkeydown="SearchOnEnter"
placeholder="Search the address space by name or path…" />
<button class="btn btn-outline-primary" data-test="node-search-button" @onclick="SearchAsync">Search</button>
</div>
@if (ShowSearch)
{
<div class="input-group mb-3">
<input class="form-control" data-test="node-search-input"
@bind="_searchQuery" @bind:event="oninput"
@onkeydown="SearchOnEnter"
placeholder="Search the address space by name or path…" />
<button class="btn btn-outline-primary" data-test="node-search-button" @onclick="SearchAsync">Search</button>
</div>
}
@if (_searchActive)
@if (ShowSearch && _searchActive)
{
<div class="node-browser-search mb-3">
@if (_searchResults.Count == 0)
@@ -113,8 +116,19 @@
[Parameter] public EventCallback<string> OnSelected { get; set; }
[Parameter] public EventCallback OnCancelled { get; set; }
/// <summary>Additive: receives the full selected <see cref="BrowseNode"/> (incl.
/// DataType) on confirm, alongside the existing string-id <see cref="OnSelected"/>.
/// Optional — existing callers that only wire OnSelected are unaffected.</summary>
[Parameter] public EventCallback<BrowseNode> OnNodeSelected { get; set; }
/// <summary>When false, hides the address-space search box. Set false for protocols
/// that don't implement IAddressSpaceSearchable (e.g. MxGateway), where search would
/// always fail. Default true preserves OPC UA behaviour.</summary>
[Parameter] public bool ShowSearch { get; set; } = true;
private bool _isVisible;
private string? _selectedNodeId;
private BrowseNode? _selectedNode;
private string _manualNodeId = "";
private BrowseFailure? _failure;
private string _failureMessage = "";
@@ -148,6 +162,10 @@
/// </summary>
public string? DataType { get; init; }
/// <summary>The originating BrowseNode, retained so selection can emit the
/// full node (incl. DataType) via OnNodeSelected.</summary>
public BrowseNode? Source { get; init; }
public List<TreeNode>? Children { get; set; } // null = not loaded yet
public bool Expanded { get; set; }
public bool Loading { get; set; }
@@ -174,6 +192,14 @@
_isVisible = true;
_manualNodeId = initialNodeId ?? "";
_selectedNodeId = initialNodeId;
_selectedNode = null;
// Reset any prior search state so a reused dialog instance never renders
// stale results on re-open (and the search panel stays fully suppressed
// when ShowSearch is false).
_searchActive = false;
_searchQuery = "";
_searchResults = new();
_searchCapReached = false;
await LoadRootAsync();
}
@@ -195,7 +221,7 @@
}
private static TreeNode ToTreeNode(BrowseNode c) =>
new(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren) { DataType = c.DataType };
new(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren) { DataType = c.DataType, Source = c };
private async Task ToggleAsync(TreeNode node)
{
@@ -311,6 +337,7 @@
if (node.NodeClass != BrowseNodeClass.Variable) return;
_selectedNodeId = node.NodeId;
_manualNodeId = node.NodeId;
_selectedNode = node;
}
private void Select(TreeNode node)
@@ -318,6 +345,7 @@
if (node.NodeClass != BrowseNodeClass.Variable) return;
_selectedNodeId = node.NodeId;
_manualNodeId = node.NodeId;
_selectedNode = node.Source;
}
// Task 17: map each BrowseFailureKind to a friendly UI message. Messages are
@@ -349,13 +377,19 @@
private void UseManual()
{
_selectedNodeId = _manualNodeId.Trim();
_selectedNode = null;
}
private async Task Confirm()
{
_isVisible = false;
if (!string.IsNullOrWhiteSpace(_selectedNodeId))
{
await OnSelected.InvokeAsync(_selectedNodeId!);
if (OnNodeSelected.HasDelegate)
await OnNodeSelected.InvokeAsync(
_selectedNode ?? new BrowseNode(_selectedNodeId!, _selectedNodeId!, BrowseNodeClass.Variable, HasChildren: false));
}
}
private async Task Cancel()
@@ -0,0 +1,30 @@
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
namespace ZB.MOM.WW.ScadaBridge.CentralUI.Components.Pages.Operations;
/// <summary>
/// Best-effort map from the MxGateway/Galaxy free-form attribute type name
/// (<c>GalaxyAttribute.data_type_name</c>, surfaced on <c>BrowseNode.DataType</c>)
/// to a ScadaBridge <see cref="DataType"/>. Used by the Secured Writes page to
/// pre-fill the data-type dropdown when a tag is picked. Unknown or blank names
/// return false so the operator's existing selection is left untouched. Galaxy
/// type names are free-form text, not a stable enum — keep this tolerant.
/// </summary>
internal static class SecuredWriteDataTypeMapper
{
public static bool TryMap(string? galaxyTypeName, out DataType dataType)
{
dataType = default;
if (string.IsNullOrWhiteSpace(galaxyTypeName)) return false;
switch (galaxyTypeName.Trim().ToLowerInvariant())
{
case "boolean": case "bool": dataType = DataType.Boolean; return true;
case "integer": case "int": case "int32": dataType = DataType.Int32; return true;
case "float": dataType = DataType.Float; return true;
case "double": dataType = DataType.Double; return true;
case "string": dataType = DataType.String; return true;
case "time": dataType = DataType.DateTime; return true;
default: return false;
}
}
}
@@ -5,6 +5,8 @@
@using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Repositories
@using ZB.MOM.WW.ScadaBridge.Commons.Messages.Management
@using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums
@using ZB.MOM.WW.ScadaBridge.CentralUI.Components.Dialogs
@using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol
@using ZB.MOM.WW.ScadaBridge.Security
@inject ISecuredWriteService SecuredWriteSvc
@inject ISiteRepository SiteRepository
@@ -58,8 +60,14 @@
</div>
<div class="col-md-4">
<label class="form-label form-label-sm">Tag path</label>
<input class="form-control form-control-sm" @bind="_formTagPath"
placeholder="e.g. PLC1.Pump.Setpoint" data-test="secured-write-tagpath" />
<div class="input-group input-group-sm">
<input class="form-control form-control-sm" @bind="_formTagPath"
placeholder="e.g. PLC1.Pump.Setpoint" data-test="secured-write-tagpath" />
<button class="btn btn-outline-secondary" type="button"
disabled="@(!CanBrowse)"
title="@(CanBrowse ? "Browse tags" : "Pick a site and MxGateway connection first")"
@onclick="OpenBrowser" data-test="secured-write-browse">Browse…</button>
</div>
</div>
<div class="col-md-4">
<label class="form-label form-label-sm">Value</label>
@@ -89,6 +97,11 @@
Submit for verification
</button>
</div>
<NodeBrowserDialog @ref="_browserRef"
SiteId="@_formSiteIdentifier"
ConnectionName="@_formConnectionName"
ShowSearch="false"
OnNodeSelected="OnTagPicked" />
</div>
</div>
</Authorized>
@@ -226,6 +239,25 @@
private string _formValueType = nameof(DataType.Boolean);
private string _formComment = "";
private NodeBrowserDialog? _browserRef;
private bool CanBrowse =>
!string.IsNullOrWhiteSpace(_formSiteIdentifier)
&& !string.IsNullOrWhiteSpace(_formConnectionName);
private async Task OpenBrowser()
{
if (!CanBrowse || _browserRef is null) return;
await _browserRef.ShowAsync(_formSiteIdentifier, _formConnectionName, _formTagPath);
}
private void OnTagPicked(BrowseNode node)
{
_formTagPath = node.NodeId;
if (SecuredWriteDataTypeMapper.TryMap(node.DataType, out var dt))
_formValueType = dt.ToString();
}
private bool _submitting;
private bool _actionInProgress;
@@ -18,7 +18,7 @@ public record MxReadOutcome(string TagPath, bool Success, object? Value, Quality
public record MxWriteOutcome(string TagPath, bool Success, string? Error);
/// <summary>One node in a Galaxy browse level.</summary>
public record MxBrowseChild(string NodeId, string DisplayName, BrowseNodeClass NodeClass, bool HasChildren);
public record MxBrowseChild(string NodeId, string DisplayName, BrowseNodeClass NodeClass, bool HasChildren, string? DataType = null);
/// <summary>
/// Seam over the MxAccess Gateway .NET client + Galaxy repository client. Decouples
@@ -267,7 +267,7 @@ public class MxGatewayDataConnection : IDataConnection, IBrowsableDataConnection
// and no continuation is ever surfaced (ContinuationToken stays null).
var (children, truncated) = await _client.BrowseChildrenAsync(parentNodeId, cancellationToken);
var nodes = children
.Select(c => new BrowseNode(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren))
.Select(c => new BrowseNode(c.NodeId, c.DisplayName, c.NodeClass, c.HasChildren, DataType: c.DataType))
.ToList();
return new BrowseChildrenResult(nodes, truncated);
}
@@ -266,7 +266,8 @@ public sealed class RealMxGatewayClient : IMxGatewayClient
attr.FullTagReference,
attr.AttributeName,
BrowseNodeClass.Variable,
false));
false,
string.IsNullOrEmpty(attr.DataTypeName) ? null : attr.DataTypeName));
}
}
@@ -0,0 +1,101 @@
using Bunit;
using Microsoft.AspNetCore.Components;
using Microsoft.Extensions.DependencyInjection;
using NSubstitute;
using ZB.MOM.WW.ScadaBridge.CentralUI.Components.Dialogs;
using ZB.MOM.WW.ScadaBridge.CentralUI.Services;
using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol;
using ZB.MOM.WW.ScadaBridge.Commons.Messages.Management;
namespace ZB.MOM.WW.ScadaBridge.CentralUI.Tests.Components;
public class NodeBrowserDialogSelectionTests : BunitContext
{
private readonly IBrowseService _browse = Substitute.For<IBrowseService>();
public NodeBrowserDialogSelectionTests()
{
Services.AddSingleton(_browse);
_browse.BrowseChildrenAsync(
Arg.Any<string>(), Arg.Any<string>(), Arg.Any<string?>(),
Arg.Any<string?>(), Arg.Any<CancellationToken>())
.Returns(new BrowseNodeResult(Array.Empty<BrowseNode>(), Truncated: false, Failure: null));
_browse.SearchAsync(
Arg.Any<string>(), Arg.Any<string>(), Arg.Any<string>(),
Arg.Any<int>(), Arg.Any<int>(), Arg.Any<CancellationToken>())
.Returns(new SearchAddressSpaceResult(
Matches: new[]
{
new AddressSpaceMatch(
new BrowseNode("ns=2;s=Pump1.Speed", "Speed", BrowseNodeClass.Variable, HasChildren: false, DataType: "Double"),
Path: "Devices/Pump1/Speed"),
},
CapReached: false, Failure: null));
}
[Fact]
public void Confirm_emits_full_node_with_datatype_on_OnNodeSelected()
{
BrowseNode? captured = null;
var cut = Render<NodeBrowserDialog>(p => p
.Add(c => c.SiteId, "plant-a")
.Add(c => c.ConnectionName, "PLC-OPC")
.Add(c => c.OnNodeSelected, EventCallback.Factory.Create<BrowseNode>(this, n => captured = n)));
cut.InvokeAsync(() => cut.Instance.ShowAsync("plant-a", "PLC-OPC", null));
cut.Render();
cut.Find("[data-test=node-search-input]").Input("Pump1");
cut.Find("[data-test=node-search-button]").Click();
cut.FindAll("[data-test=node-search-result] a")[0].Click();
cut.Find(".modal-footer .btn-primary").Click();
Assert.NotNull(captured);
Assert.Equal("ns=2;s=Pump1.Speed", captured!.NodeId);
Assert.Equal("Double", captured.DataType);
}
[Fact]
public void ShowSearch_false_hides_search_box()
{
var cut = Render<NodeBrowserDialog>(p => p
.Add(c => c.SiteId, "plant-a")
.Add(c => c.ConnectionName, "PLC-MX")
.Add(c => c.ShowSearch, false));
cut.InvokeAsync(() => cut.Instance.ShowAsync("plant-a", "PLC-MX", null));
cut.Render();
Assert.Empty(cut.FindAll("[data-test=node-search-input]"));
}
// The Secured Writes page browses MxGateway with ShowSearch=false, so the
// ONLY user-reachable selection path in production is the tree (Select(TreeNode)
// → _selectedNode = node.Source). This guards that path end-to-end: a tree-node
// click must carry the node's DataType through Confirm → OnNodeSelected.
[Fact]
public void TreeSelect_emits_full_node_with_datatype_on_OnNodeSelected()
{
_browse.BrowseChildrenAsync(
Arg.Any<string>(), Arg.Any<string>(), Arg.Any<string?>(),
Arg.Any<string?>(), Arg.Any<CancellationToken>())
.Returns(new BrowseNodeResult(
new[] { new BrowseNode("Area1.Pump.Speed", "Speed", BrowseNodeClass.Variable, HasChildren: false, DataType: "Float") },
Truncated: false, Failure: null));
BrowseNode? captured = null;
var cut = Render<NodeBrowserDialog>(p => p
.Add(c => c.SiteId, "plant-a")
.Add(c => c.ConnectionName, "PLC-MX")
.Add(c => c.ShowSearch, false)
.Add(c => c.OnNodeSelected, EventCallback.Factory.Create<BrowseNode>(this, n => captured = n)));
cut.InvokeAsync(() => cut.Instance.ShowAsync("plant-a", "PLC-MX", null));
cut.Render();
// Click the tree node's select link (tree path, not search).
cut.Find(".node-browser-tree a").Click();
cut.Find(".modal-footer .btn-primary").Click();
Assert.NotNull(captured);
Assert.Equal("Area1.Pump.Speed", captured!.NodeId);
Assert.Equal("Float", captured.DataType);
}
}
@@ -0,0 +1,35 @@
using ZB.MOM.WW.ScadaBridge.CentralUI.Components.Pages.Operations;
using ZB.MOM.WW.ScadaBridge.Commons.Types.Enums;
namespace ZB.MOM.WW.ScadaBridge.CentralUI.Tests.Components;
public class SecuredWriteDataTypeMapperTests
{
[Theory]
[InlineData("Boolean", DataType.Boolean)]
[InlineData("bool", DataType.Boolean)]
[InlineData("Integer", DataType.Int32)]
[InlineData("int", DataType.Int32)]
[InlineData("Int32", DataType.Int32)]
[InlineData("Float", DataType.Float)]
[InlineData("Double", DataType.Double)]
[InlineData("String", DataType.String)]
[InlineData("Time", DataType.DateTime)]
[InlineData(" double ", DataType.Double)] // trimmed + case-insensitive
public void TryMap_known_galaxy_types_map(string galaxy, DataType expected)
{
Assert.True(SecuredWriteDataTypeMapper.TryMap(galaxy, out var dt));
Assert.Equal(expected, dt);
}
[Theory]
[InlineData(null)]
[InlineData("")]
[InlineData(" ")]
[InlineData("ElapsedTime")]
[InlineData("SomeVendorType")]
public void TryMap_unknown_or_blank_returns_false(string? galaxy)
{
Assert.False(SecuredWriteDataTypeMapper.TryMap(galaxy, out _));
}
}
@@ -245,6 +245,24 @@ public class MxGatewayDataConnectionTests
Assert.Equal(BrowseNodeClass.Variable, result.Children[1].NodeClass);
}
[Fact]
public async Task BrowseChildrenAsync_surfaces_attribute_datatype()
{
var fake = new FakeMxGatewayClient
{
BrowseHandler = _ => (new List<MxBrowseChild>
{
new("Area1.Pump.Speed", "Speed", BrowseNodeClass.Variable, false, "Double"),
}, false)
};
var adapter = NewAdapter(fake);
await adapter.ConnectAsync(Details());
var result = await adapter.BrowseChildrenAsync(null);
Assert.Equal("Double", result.Children[0].DataType);
}
[Fact]