Every downing decision of LeaderAutoDowningProvider is now logged under a
[leader-auto-down] prefix: start-up snapshot (leader, window, already-unreachable),
unreachable observed + its window (Warning), skipped because already Down/Exiting,
pending Down cancelled on reachable-again/removed, timed out on a non-leader and kept
pending, leadership gained/lost, and DOWNING (Warning) before Cluster.Down. Akka's own
AutoDown logged only the final Down. Decision semantics are unchanged.
New real two-node scenarios (IntegrationTests/Cluster/LeaderAutoDownScenarioTests),
built from production BuildHocon with self-first seeds:
- both nodes cold-start together -> one cluster, nobody downed past FD + window;
- lone cold start with the peer dead (the down-if-alone cold-recreate shape) stays Up,
then the peer cold-starts and joins;
- flapping peer via Akka's trttl throttler Blackhole: unreachable shorter than the
window, repeated past it in total -> never downed; positive control asserts the cuts
really produced unreachability;
- partition held past the window -> each side downs the other, both stay Up and
leader (the accepted dual-active trade);
- switch off: auto-down loads AutoDowning, keep-oldest loads SplitBrainResolverProvider,
only leader-auto-down loads the in-repo provider.
Unit: flapping never downs; a flapping member that finally stays unreachable is downed
exactly once a full window after its LAST unreachable; each decision log line.
Mutation-proved: no timer cancel on reachable -> flap-then-stay unit fails; reachable
ignored -> both unit flapping tests, the cancel-log test and the real-cluster flapping
test fail; DOWNING log dropped -> log test fails; provider never downs -> partition
test fails; auto-down miswired to the new provider -> switch-off theory fails.
Docker failover drill not run (it would rebuild the shared scadabridge:latest image
and reuse the shared rig volumes while another agent works in the repo); filed as
deploy gate ScadaBridge#116. Default remains auto-down.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Adds LeaderAutoDowningProvider (Host/Actors), a line-for-line port of Akka.NET
1.5.62 AutoDowning/AutoDown/AutoDownBase read from the decompiled assembly: the
leader among the reachable members downs a peer unreachable for StableAfter; a
non-leader records it as pending and downs it on becoming leader; reachable-again
or removed members are forgotten; Down/Exiting members are skipped. Its window is
carried under scadabridge.cluster.leader-auto-down.unreachable-after, so no
deprecated auto-down-unreachable-after key is emitted and Akka's boot-time
"keep-majority will be used instead" warning goes away. DownRemovalMargin reads
akka.cluster.down-removal-margin exactly as AutoDowning does (default off).
New SplitBrainResolverStrategy value "leader-auto-down", wired through BuildHocon
and ClusterOptionsValidator. The default stays "auto-down"; auto-down and
keep-oldest HOCON is byte-identical to before. Placed in Host, not
ClusterInfrastructure, per the Code Placement rule (ClusterInfrastructure stays
Akka-free).
Tests: HOCON + validator units; LeaderAutoDownTests ports Akka's AutoDownSpec
cases (leader-only, pending-on-leader-change, losing leadership, reachable again,
removed, Down/Exiting skipped, single Down per member); LeaderAutoDownFailoverTests
clones SbrFailoverTests' oldest-crash and younger-crash cases on a real two-node
cluster plus a test that Akka actually loaded the provider and its downing actor.
Mutation-checked: a provider that never calls Cluster.Down fails both failover
tests; never-downs, leader-check-dropped, reachable-ignored and pending-not-flushed
mutations each fail the unit tests.
Remaining gate before switching the default: the docker failover drill
(DRILL_MODE=active and standby mode) on leader-auto-down.