Commit Graph

99 Commits

Author SHA1 Message Date
Joseph Doherty a2e9d71824 feat(dcl): move the OPC UA client to OPC Foundation SDK 2.0.1 (#125)
OPCFoundation.NetStandard.Opc.Ua.Client and the test-only .Server move
1.5.378.182 -> 2.0.1, the version OtOpcUa master runs (lmxopcua#782; #799
and #801 closed). Transitive Core/Core.Types/Types/Configuration/
Security.Certificates resolve to 2.0.1.

API breaks fixed in the DCL adapter:
- Built-in types are immutable structs (Variant, DataValue, NodeId,
  LocalizedText, StatusCode, ArrayOf<T>). New OpcUaValueBoundary restores
  the SDK 1.5 CLR shapes for every read, subscription and alarm-event
  value (byte[], UTC DateTime with no-timestamp = MinValue, Guid,
  detached arrays) and builds write variants with SDK 1.5's
  new Variant(object) semantics (byte[] = ByteString scalar).
- StatusCodes members are no longer constants: switches/patterns over
  them (verify-outcome mapping, connection-level classification,
  BadResourceUnavailable) match by value.
- CertificateIdentifier no longer caches a certificate and the
  CertificateValidator/CertificateValidation event is gone: the
  configuration's CertificateManager owns trust lists and the loaded
  application certificate and is disposed with the session; auto-accept
  and the verify probe's capture-and-reject use AcceptError.
- new UserIdentity(X509Certificate2) is gone: X509 user identities use
  X509IdentityTokenHandler with an on-demand PFX provider (still fails
  fast on a missing file/key).
- DefaultSessionFactory takes the telemetry context; collections are
  ArrayOf<T>; EventFilter select clauses and ContentFilter operands are
  built immutably.

UserName identity (lmxopcua#880): SDK 2's default handler sends a
password over 64 bytes - every 65-character OtOpcUa API key - as an
RsaEncryptedSecret that SDK 1.5 servers reject with BadIdentityTokenInvalid
and SDK 2 servers accept only within a 5-minute clock window (#873). The
DCL now always uses LegacyRsaUserNameIdentityTokenHandler (ported from
OtOpcUa be28aa44), i.e. exactly what it sent on SDK 1.5, so it logs in to
both server generations during a mixed rollout.

Tests: the in-process secured test server is ported to SDK 2 and can
admit an API key; new tests cover the handler (mutation-checked: 5 of 7
fail with the SDK default handler), the value boundary, and a 65-char key
end to end over None/Sign/SignAndEncrypt with a wrong key reaching the
key check (BadIdentityTokenRejected).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 22:20:53 -05:00
Joseph Doherty dd4f1c2aa3 fix(alarms): Severity runs one direction, higher = more urgent; raw priority kept (#129)
AlarmConditionState.Severity mixed two conventions: OPC UA rows carried Part 9
Severity (higher = more severe) while MxGateway native alarms and computed
alarms carried a raw AVEVA-style priority (1 = most urgent). Every consumer
ranks higher as worse, so Worst Severity, the severity filter/sort and the
site event-log Error threshold picked the LEAST urgent MxGateway/computed
alarms.

- AlarmPriorityBands: the OtOpcUa GalaxyAlarmPriority table (lmxopcua#887,
  b61f3e05), value for value: 1-250 -> 1000, 251-500 -> 750, 501-750 -> 500,
  751-999 -> 250; <= 0 clamps to Critical, > 999 to Low.
- MxGatewayAlarmMapper bands the gateway severity (= AVEVA priority);
  AlarmConditionStateFactory.ForComputed bands PriorityLevel. OPC UA unchanged.
- AlarmConditionState gains trailing Priority (int?): the raw source number,
  exactly the pre-#129 Severity. AlarmStateChanged.Priority and the wire
  AlarmStateUpdate.priority keep that meaning (no proto change); central derives
  Severity by kind (SeverityFromPriority), so an older site decodes correctly.
- ScriptAlarm gains trailing Priority. The native MES 900-999 band and the MES
  API Severity/MinSeverity/MaxSeverity key off Priority; rig seed scripts moved
  from a.Severity to a.Priority, so MES output is unchanged.
- AlarmActor raise logs Error when the banded severity >= 700 (same threshold
  as NativeAlarmActor): priority 1-500 Error, 501+ Warning (was raw >= 700).
- NativeAlarmActor upgrades pre-#129 native_alarm_state rows on rehydrate.
- Debug snapshot decode restores Condition.Priority from the row's priority.
- Docs: Commons, DCL, SiteRuntime, Communication, CentralUI, InboundAPI,
  HighLevelReqs, MES alarm-status plan, CLAUDE.md.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 14:02:54 -05:00
Joseph Doherty 94ae186050 fix(dcl): MxGateway resume cursor ignores worker_sequence-0 sentinels (#128)
RealMxGatewayClient.RunEventLoopAsync stored every streamed MxEvent's
WorkerSequence as its StreamEvents resume cursor before filtering by family.
The gateway's control sentinels (ReplayGap on a resume that hit evicted
events; the opt-in StreamAttached ack) carry worker_sequence 0, so a gap
reset the cursor to 0 and the next resume became a fresh stream: no replay,
no gap signal, silent loss.

Cursor rule: advance-only (max), from real worker events (sequence > 0) only.
A ReplayGap anchors the cursor at oldest_available_sequence - 1 (the gateway's
documented gap-free resume point, valid for an empty ring too) and is logged
as a warning naming the lost interval. Sentinels never reach the value
callback.

The loop body is split into internal RunEventLoopCoreAsync(IAsyncEnumerable)
so tests drive a scripted stream; 4 of the 7 new tests fail on the old loop.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 07:35:34 -05:00
Joseph Doherty 36c64a6bb8 fix(dcl): verify-endpoint probe logs through a real logger so first-time OPC UA app-cert creation is visible (#121)
The site's DataConnectionManagerActor handed VerifyEndpointAsync a NullLogger. A secured
probe is usually what first creates a node's application certificate, so the creation
Warning carrying the thumbprint every server must trust was silently discarded (found on the
rig live gate). The actor takes an optional probe logger; the Host supplies one. Test pins
creation logged once (Warning, thumbprint), not on reuse.
2026-11-10 14:41:25 -05:00
Joseph Doherty ff8354478c fix(dcl): OPC UA secure client presents a real application certificate (#121)
Sign/SignAndEncrypt sessions failed before activation with "ApplicationCertificate
for the security profile ... cannot be found" (BadConfigurationError): both
RealOpcUaClient.ConnectAsync and the verify probe built an empty CertificateIdentifier.

- New OpcUaApplicationIdentity builds the client ApplicationConfiguration for both
  paths. Secured modes load the application certificate from a configurable own
  store (subject + ApplicationUri), auto-creating a self-signed RSA-2048 cert only
  when none exists. A persisted cert is reused across reconnect/restart and never
  silently rotated: one that no longer validates (e.g. ApplicationUri mismatch)
  fails closed. First-time creation is serialised per own store and logged at
  Warning with the thumbprint. None mode is unchanged and never touches the store.
- New OpcUaGlobalOptions: ApplicationUri, ApplicationCertificateSubject,
  OwnCertificateStorePath, AutoCreateApplicationCertificate,
  ApplicationCertificateLifetimeMonths (validated).
- Owned resources: the private-key cert is disposed on disconnect, failed connect
  and at probe end; sessions are now disposed after close, and a reconnect on the
  same instance closes the previous session first.
- CertStoreActor wrote trusted server certs to the store ROOT, which the SDK never
  reads (it uses {store}/certs), so an operator Trust never affected validation and
  SDK-rejected certs never listed. It now uses certs/ and migrates legacy root files
  on start.
- Rig: all site nodes (docker/, docker-env2/) put the four PKI stores on the
  persistent /app/data volume with a pinned ApplicationUri.
- Tests: in-process strict-trust StandardServer (test-only Opc.Ua.Server 1.5.378.106)
  exercising the real adapter through ConnectAsync and VerifyEndpointAsync for Sign
  and SignAndEncrypt: allow + read + reconnect + restart on one identity, deny when
  the client doesn't trust the server (BadCertificateUntrusted), deny when the server
  doesn't trust the client (BadSecurityChecksFailed), None untouched, concurrent
  provisioning creates one cert, URI mismatch fails without rotating, auto-create off.
  Against the pre-fix client these tests fail with the exact #121 error.
2026-11-10 13:56:47 -05:00
Joseph Doherty c810bd0f7c feat(logging): bridge Akka logging to Serilog and copy traced runs' node-log lines into the Flow Debugger (ScadaBridge#120, #56)
#120: Akka ILoggingAdapter lines used to bypass Serilog and go to stdout only.
- BuildHocon sets akka.loggers = [Host.Actors.SerilogAkkaLogger] and keeps akka.loglevel = INFO,
  so Akka Debug chatter is still filtered at the adapter. The INFO+ lines that used to reach
  stdout now go through the Serilog pipeline instead, with no extra volume.
- Lines reach the file sinks with the node enrichers. SourceContext is the logging class's full
  name, AkkaSource is the actor path, Akka's own timestamp is kept, and format arguments become
  structured properties.
- The Akka logger actor writes on its own thread, after the logging actor's LogContext is gone.
  To keep the ExecutionId, the two DCL actors log through ExecutionAwareLogging.GetLogger(Context),
  which records ExecutionLogContext.Current (a new AsyncLocal mirror of the pushed id) in an
  ExecutionTaggedLogMessage. The logger actor pushes that id again while it writes the line.

#56 remainder (coordinator decision: no replicated schema change):
- The host pipeline gains ExecutionLogCaptureSink.
- While a run is traced, its step logger registers its ExecutionId: the site ScriptLogger from the
  launcher (plus each inline CallShared child id), and the central InboundScriptLogger from the
  executor.
- Each tagged line becomes a ScriptLog row with LogSource "node" and the new
  ScriptTraceExtra.LogCategory.
- The rows count against the existing MaxLogLinesPerRun cap, are clipped at 2 000 chars, ride the
  low-priority collector lane and pass the same redactor. Untraced runs cost one volatile read.
- Lines are never copied twice. The step loggers' own forwards run inside
  ExecutionLogCapture.Suppress(), and the sink suppresses itself while it calls a target. The
  registration is declared inside the launcher's and executor's try, so it ends before the catch
  blocks log the outcome, and FlushDropped closes it.
- FlowGraphBuilder lists node lines in FlowGraph.NodeLogs and never folds them onto a step.
- The Flow Debugger shows them in a Node log card (FlowNodeLogPanel): grouped per execution under
  its run step, with an All | Warn + filter. Live and Replay both read the same rows, so site
  scope and role rules apply unchanged.
- CLI --show-logs prints them as a trailing block.

Tests: Commons ExecutionLogCaptureTests, ExecutionLogContext.Current, FlowGraphBuilder node lines.
SiteRuntime NodeLogCaptureTests covers cross-actor capture via the launcher, untraced runs
capturing nothing, no double capture of script and runtime lines or of the launcher failure line,
the shared cap, collector redaction, shared-script child ids and FlushDropped closing capture.
InboundNodeLogCaptureTests covers the central path. DCL ExecutionAwareLoggingTests covers the
DataConnectionActor write-path Debug line being tagged and an uncorrelated line not being tagged.
Host SerilogAkkaLoggerTests covers mapping, the ExecutionId crossing the logger hop, HOCON,
ActorSystem boot and the Akka line reaching a traced run's step log end to end. Host
LoggerConfigurationTests checks that the sink is wired. bUnit FlowNodeLogPanelTests and a CLI
projection test cover the UI and CLI. Every new assertion was mutation-proven.

Docs: step-logs design section 12, Component-SiteRuntime, CentralUI, InboundAPI, Host, CLI README,
CLAUDE.md.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 06:12:34 -05:00
Joseph Doherty edd0ca672f feat(logging): carry ExecutionId across actor hops onto other actors' log lines (ScadaBridge#56)
LogContext is an AsyncLocal and does not cross an Akka message hop, so the run's id now rides the
message: Commons.Observability.IExecutionCorrelated (explicit interface member, no wire change) on
SetStaticAttributeCommand, AttributeValueChanged (not for an inferred writer), ScriptCallRequest and
the four RouteTo*Requests, plus a new additive SourceExecutionId on GetAttributeRequest,
WaitForAttributeRequest, WriteAttributeBatchRequest, WriteTagRequest and WriteTagBatchRequest.
ScriptRuntimeContext stamps its id on the requests it sends, the Instance Actor hands it on to the
DCL, and the Instance, Script, Alarm, Deployment Manager and both DCL actors re-push it per message in
AroundReceive (ExecutionLogContext.PushFor: one type test when the message names no execution). The
inbound executor pushes the request's ExecutionId for the method execution.

Tests (TestKit): Instance Actor line carries the message's id, no leak from the sender's ambient
context, scope ends with the message, per-write ids inside a batched SetAttributes, ids forwarded on
DCL writes, ScriptRuntimeContext stamps; DCL adapter lines on single/batch writes carry the id;
inbound executor lines carry the request id; Commons mapping + no serialized member. Each mutation-
proved. Still open on #56: a queryable per-execution sink and a Flow Debugger section. The DCL
actors' own Akka _log lines bypass Serilog (filed #120).

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 05:28:20 -05:00
Joseph Doherty fb04b54d62 fix(dcl): map OPC UA status by severity bits so all Good subcodes are Good (ScadaBridge#117)
MapStatusCode returned Uncertain for any non-zero non-Bad code, so GoodLocalOverride,
GoodClamped and info-bit Good variants degraded to Uncertain. Now top two bits decide:
00 Good, 01 Uncertain, 10/11 Bad (BadResourceUnavailable stays Bad, #112 untouched).
The SDK IsGood/IsUncertain(uint) helpers were tried first and failed the subcode tests,
so an explicit mask is used. MxGateway mapper uses the OPC-DA quality byte (>=192 Good)
and is not affected.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 04:48:33 -05:00
Joseph Doherty 08fe5acfe4 fix(dcl): treat OPC UA BadResourceUnavailable as transient Bad; Bad+null keeps last-known value (ScadaBridge#112)
OtOpcUa's out-of-process script runner publishes 0x80040000 with a null value.
- OpcUaDataConnection: logs entry/recovery once per tag, names the symbolic
  status in read errors; never a disconnect (not in the reconnect status set).
- InstanceActor: a Bad update with no value is a quality-only transition
  (keep value, quality Bad, stream publish, no script/alarm/waiter re-eval),
  matching the connection-drop rule. Bad with a value is unchanged.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 04:38:05 -05:00
Joseph Doherty c4186509f6 refactor(health): move ISiteHealthCollector to Commons; Communication drops HealthMonitoring reference (ScadaBridge#87)
Interface now lives in Commons.Interfaces.Services; AuditLog no longer gets it
transitively through Communication. Implementation stays in HealthMonitoring.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:13:58 -05:00
Joseph Doherty a5c3de63e9 fix(dcl): coerce scalar OPC UA writes to the node DataType (#58)
Codec-encoded scalars ("True", "42.5") reached RealOpcUaClient.WriteValuesAsync
as strings and were sent as String Variants, so a Boolean/Double node answered
BadTypeMismatch (0x80740000).

RealOpcUaClient now reads each written node's DataType attribute once per
session (batched, cached, cleared on connect/disconnect; derived types and
enumerations resolved via the supertype chain) and converts non-null scalar
values with the new OpcUaWriteCoercion table: Boolean, SByte..UInt64, Float,
Double, String, DateTime, Guid, all culture-invariant. Overflow, fractional
values to integer types and unparseable strings are refused client-side with
BadTypeMismatch and a message naming the value and target type - never a
rounded value. Arrays, null, unmapped types and nodes whose DataType read
fails pass through unchanged. WriteValueAsync now surfaces the outcome's own
status code instead of always BadNodeIdUnknown. MxGateway path untouched.

Tests: OpcUaWriteCoercionTests (coercion table incl. overflow, invalid and
culture-sensitive strings) and OpcUaWriteCoercionLiveTests (RequiresOpcUa:
String writes to Double/Boolean/UInt32 opc-plc nodes read back typed; reverting
the coercion reproduces 0x80740000). Component-DataConnectionLayer.md updated.
2026-11-06 16:08:33 -05:00
Joseph Doherty e60c316f30 fix(dcl): queue a create whose actor name belongs to a still-terminating child instead of refusing it (review 2026-10-21 follow-up L2) 2026-10-22 09:58:46 -04:00
Joseph Doherty 099b2221d6 fix(dcl): ASCII-only connection actor names, guarded ActorOf, and gate rejection of colliding connection names (review 2026-10-21 lane A M2)
ConnectionActorNames.Sanitize (shared by the DCL manager and the site deploy
gate) keeps ASCII letters/digits and -_.*+:@&=,!~';() only. The manager fails a
connection whose sanitised name is invalid or already used (Error + site
event) instead of restarting; DeployCompileValidator rejects a config whose
connection names collide after sanitising.
2026-10-22 09:10:26 -04:00
Joseph Doherty 394234b450 fix(dcl): advance the session generation when a reconnect attempt is issued, not when its result is applied (review 2026-10-21 02/C1 follow-up) 2026-10-22 08:33:00 -04:00
Joseph Doherty d8d44e0b87 perf(dcl): coalesce MxGateway alarm stream reopens across a subscribe burst (review 2026-10-21 02/P3) 2026-10-22 08:33:00 -04:00
Joseph Doherty e6406c494c fix(dcl): async OPC UA endpoint discovery bounded by OperationTimeoutMs/verify budget; adapter connect never runs on the actor thread (review 2026-10-21 02/P2) 2026-10-22 08:33:00 -04:00
Joseph Doherty cfe95a7e5a fix(dcl): log the initial connect to Site Event Logging like every other transition (review 2026-10-21 02/U4) 2026-10-22 08:33:00 -04:00
Joseph Doherty 3543a7f295 fix(dcl): feed ScadaBridge:MxGateway:ClientNamePrefix into the MxGateway client-name fallback (review 2026-10-21 02/U1, 08/O2) 2026-10-22 08:33:00 -04:00
Joseph Doherty f18d3adbfc fix(dcl): forget an OPC UA condition's last state once it returns to normal (review 2026-10-21 02/L3) 2026-10-22 08:33:00 -04:00
Joseph Doherty d51ea5136a fix(dcl): drop values for unsubscribed tags before quality bookkeeping; cancel the reconnect re-seed when its session ends (review 2026-10-21 02/L2, 02/L4) 2026-10-22 08:33:00 -04:00
Joseph Doherty 8c1bd2c3fc fix(dcl): advance the session generation on same-adapter reconnect and session-scope MxGateway subscription ids (review 2026-10-21 02/C1, 02/L1) 2026-10-22 08:33:00 -04:00
Joseph Doherty b811a2451b fix(dcl): remove unused poll-based WriteBatchAndWaitAsync from IDataConnection and both adapters (review 2026-10-21 02/U3) 2026-10-22 08:33:00 -04:00
Joseph Doherty 0ffd4bdbea docs(src): fix CommentChecker findings across src/ — 1,032 → 5 (all false positives)
Comment/XML-doc changes only, no code logic:
- strip project-tracking references (WP*, P*-*, row-NN, #NN, Task N) from
  comments, keeping the explanatory rationale
- add missing summaries, <param>, <returns>, <typeparam> and <inheritdoc/>
- replace misused <inheritdoc/> with real docs; where <inheritdoc/> was
  combined with useful remarks, move the rationale into // comments
- drop stale replicationActor <param> on DeploymentManagerActor ctor

Remaining 5 are false positives (CWE-1236 x2, failures-1, year-0001, M365).
Build 0 errors / 0 warnings.
2026-10-07 14:12:25 -04:00
Joseph Doherty 67a3950f74 fix(site-secrets): one shared secret: reference parser for scanner and MxGateway adapter
Final review M3: SecretReferenceScanner.TryParseSecretReference (trimmed, case-insensitive
prefix, trimmed name, empty = not a reference, ${secret:} never matches) is used by the scanner
and by MxGatewayDataConnection's ApiKey resolution, so a padded or case-variant reference
resolves the name central ships. A bare 'secret:' ApiKey now fails closed. M7: unit test pins
stamped hash == ComputeCurrentArtifactHashesAsync with a non-empty Secrets list.
2026-09-28 21:08:34 -04:00
Joseph Doherty 9ee402bbcd Resolve all 46 low-severity architecture review findings 2026-09-09 22:56:36 -04:00
Joseph Doherty 9a87d7a328 Resolve all 33 medium-severity architecture review findings
Second slice of the 2026-09-09 whole-system review remediation
(docs/plans/2026-09-09-arch-review.md §10), on top of the High slice 146a1323.

Runtime/devices: SR-2 alarm on-trigger integration scope; SR-3 correlated NativeAlarmActor
subscribe retry; SR-4 immutable audited DB target; SR-5 ordered InstanceActor stop/flush;
SR-12 rehydration fence; SR-13 S&F gate recheck per delivery; DC-4 no OPC UA security
downgrade; DC-5 alarm snapshot for every new subscriber; ORCH-1 sync-dispose joins the pump.

Management/UI: MG-2 site scope on audit tree + Flow Debugger Replay; MG-3 stale-probe memo
removed; MG-4 server-owned bulk-deploy deadline; UI-5 sandbox runs in a killable child
process (new CentralUI.SandboxWorker project); UI-14 bounded sandbox output/IPC.

Edge/audit: EI-1 relay audit ownership; EI-2 SkipBodyCapture suppresses error text; EI-3/EI-11
error-field redaction + caps; EI-4 single relay deadline, pre-execution-only retry; EI-5
authenticated relay provenance; EI-10 body cap before audit read.

Persistence/contracts: DL-1 global Instance.UniqueName unique index + conflict translation;
DL-2 DataConnection protocol config encrypted at rest (migration
20260909203046_EnforceGlobalInstanceNamesAndProtectProtocolConfiguration — coordinated
central upgrade, old binaries cannot read protected rows); DL-3 bounded Replay paging;
DL-6 cross-site Overwrite of a deployed instance rejected; XC-4 proto descriptor contract test.

Config/hygiene: XC-1 central listener isolation by local port; XC-2/XC-3 inert SMTP + cron
keys removed from rig settings; CM-2 env2 bootstrap guard enabled; DC-6 deploy site exit code;
DC-7 notifier retries only explicit standby rejection; XC-5 ClusterClient purged from docs.

Gates recorded in the report: build 0/0, 9 397 passed / 0 failed, rig redeployed on all
eight nodes with the migration applied. 46 Low findings remain open.
2026-09-09 22:05:30 -04:00
Joseph Doherty 146a13238f Resolve all high-severity architecture review findings 2026-09-09 16:13:58 -04:00
Joseph Doherty da0bfe2be1 fix(dcl): MxGateway adapter treats a graceful end of the event stream as a disconnect — a dashboard 'close session' (or graceful gateway shutdown) completes the stream with OK, leaving the adapter Connected on a dead session: values frozen at last GOOD quality, every write 'Session … was not found' until restart (QA vq03 Z28061 MoveIn, 2026-08-20). Pinned: signals once while connected, silent for superseded loops / own teardown 2026-08-20 16:51:13 -04:00
Joseph Doherty 6823e7e3fa fix(dcl): P2-5 seed probe-resolved tags; P2-6 close the Connecting/Reconnecting AdapterDisconnected gap
P2-5 — the tag-resolution PROBE was the only subscribe path that did not seed.
HandleSubscribe carries seeds back on SubscribeCompleted and ReSubscribeAll re-seeds
after a reconnect, because a fresh advise only yields a value on the source's next
CHANGE. HandleRetryTagResolution did neither, so a tag that resolved LATE (device still
booting, item created after deployment) and then never changed had no value path at all.
OPC UA masks it with the initial data-change notification on subscription creation; an
MxGateway advise can legitimately return VT_EMPTY, so a static tag stayed Uncertain for
the life of the connection. New SeedNewlyResolvedTags reads the round's newly resolved
tags and delivers them through the normal generation-guarded TagValueReceived path —
directly rather than on the completion message (the probe only covers tags already
registered in _instancesByTag, so the initial subscribe's ordering hazard does not
apply), and as its own fire-and-forget task so the seed reads never delay the
BatchSubscribeCompleted that re-arms the retry timer.

P2-6 — only the Connected state handled AdapterDisconnected; in Connecting and
Reconnecting it fell through to Unhandled. A connect that succeeds and drops again before
its piped ConnectResult is applied therefore delivered the disconnect FIRST, where it was
discarded, and ConnectResult(true) then declared the connection up on a dead adapter. An
adapter raises Disconnected at most once per successful connect (OpcUaDataConnection's
once-only _disconnectFired, reset only by the next successful ConnectAsync), so a
connection with no subscriptions — nothing to fail at connection level and drive the
reconnect machine — sat Connected on a dead adapter until the process restarted. Both
states now record the disconnect in _disconnectDuringConnectAttempt (cleared at the top of
HandleAttemptConnect, so it only ever refers to the attempt in flight) and both result
handlers demote such a "success" to the ordinary connect-FAILURE tail — counting toward
the failover budget and re-arming the retry timer. A flag rather than Stash: the stash has
no selective drop, so a stashed disconnect would be replayed after the next successful
connect and cost a spurious reconnect cycle.

AdapterDisconnected is now stamped with the adapter generation (hooked via a
per-adapter closure instead of a method group; SwapAdapter hooks AFTER the bump), and
IsStaleDisconnect drops a notification from a swapped-out adapter in all three states —
the disconnect twin of IsStaleConnectResult. SwapAdapter's unhook cannot stop an event
already executing on a background thread, so without the fence an endpoint the operator
has just reconfigured AWAY from could knock the healthy replacement into a reconnect.

Tests: DataConnectionProbeSeedTests + DataConnectionDisconnectRaceTests (4 new). The
race is reproduced by ORDERING, not timing — the connect is held on a gate, Disconnected
is raised while the actor sits idle, and a GetHealthReport round trip is the mailbox
barrier; no sleeps. All 4 were proved to fail against the pre-fix behaviour via a
targeted revert of the four behaviour sites (the stale-generation test cannot be proved
by a plain revert — the record carried no generation before this change, so the test
would not compile; noted in its doc comment). Full DCL suite 346/346 green.
2026-08-19 16:41:03 -04:00
Joseph Doherty 26ab6f8f09 fix(dcl): generation-fence ConnectResult + roll back failed OPC UA subscribe batches (arch-review 2026-08-19 P2-3 + P2-4)
P2-3. ConnectResult was the last piped completion with no adapter generation on
it, so a connect launched against generation N and answered after the adapter had
been swapped (failover, or the row-97 in-place reconfigure) was applied to its
REPLACEMENT. A stale success drove ReSubscribeAll + BecomeConnected against an
adapter that had never connected, and the replacement's own result then landed in
the Connected state where nothing handles it. With a bad new endpoint the batch
subscribes failed at connection level with a log line only, no AdapterDisconnected
ever fired, and the idempotent-reconfigure guard refused a re-send of the same
configuration — only a restart recovered the connection. A stale FAILURE was as
wrong the other way: it counted toward failover and re-armed the reconnect timer
underneath the attempt genuinely in flight.

HandleAttemptConnect now stamps the generation and both handlers open with the
same guard the subscribe leg got in c4d3c8b8, dropping a mismatched result whole.
The adapter instance is deliberately NOT carried: unlike a subscribe completion a
connect result holds no adapter-scoped handles to release, and SwapAdapter has
already disposed the outgoing adapter. Dropping cannot wedge the machine — every
generation bump (CountFailureAndMaybeFailover, BecomeReconnecting's failover
branch, HandleReconfigure through it) arms an AttemptConnect for the new
generation, and the state stays Connecting/Reconnecting until that answers.

P2-4. CreateSubscriptionsCoreAsync registers each monitored item as it places it
(_callbacks, _itemShard, shard budget, the SDK subscription's item list) and only
then issues ApplyChanges, so a throw there propagated with every registration
still in place and nothing holding a handle to release them. The actor reads the
throw as a whole-chunk fault and re-issues the SAME batch on its backoff timer, so
each probe grew the bookkeeping again. Placement + apply moved to
PlaceAndApplyAsync behind a try/catch that unwinds via the existing
ReleaseFailedItem (per-item try, so one failure neither stops the rest nor
replaces the original fault); no ApplyChanges is re-issued, and items a partial
apply did reach the server with are reclaimed when the shard and session are torn
down on reconnect.

That reconnect is the other half: IsConnectionLevelFailure knew nothing about
ServiceResultException, which is how the SDK reports a dead session — so a dead
session classified as a per-tag resolution failure for the whole chunk. It now
also matches a narrow set of session/channel status codes (BadSessionIdInvalid,
BadSessionClosed, BadSessionNotActivated, BadSecureChannelClosed,
BadSecureChannelIdInvalid, BadServerNotConnected, BadConnectionClosed,
BadCommunicationError, BadNotConnected). Per-node codes such as BadNodeIdUnknown
stay per-tag — that is exactly the device-still-booting case the resolution timer
exists for.

Tests: DataConnectionStaleConnectResultTests (stale success neither connects nor
re-subscribes against the new adapter; stale failure does not disturb the current
attempt; the current generation's result is still processed after a stale drop) —
all 3 fail with the guards removed. DataConnectionOpcUaFaultClassificationTests
(bad-session drives reconnect — fails unfixed; bad-node-id stays per-tag).
RealOpcUaClientBatchRollbackTests (no residual registrations after an ApplyChanges
throw; repeated failed batches do not grow the bookkeeping) — both fail with the
rollback removed. Full DCL suite 342/342 green.
2026-08-19 14:49:24 -04:00
Joseph Doherty 59468399db fix(dcl): reset MxGateway alarm-stream state on reconnect so the native-alarm feed resumes (arch-review 2026-08-19 P2-2 High)
ConnectAsync reset the event loop and client on reconnect but left
_alarmCts/_alarmSubCount/_alarmSubSources/_alarmStreamPrefix untouched.
The orphaned old RunAlarmStreamAsync loop kept retrying the disposed
client every 5s forever, and SubscribeAlarmsAsync's coverage check saw
the stale state and short-circuited the actor's post-reconnect
transparent re-subscribe (ReSubscribeAllAlarms) without ever opening a
stream on the new client — freezing the native-alarm mirror until
failover/redeploy. Reset the alarm state in ConnectAsync, mirroring the
existing lock-guarded block in DisconnectAsync/DisposeAsync.
2026-08-19 13:54:45 -04:00
Joseph Doherty c4d3c8b875 fix(dcl): carry adapter generation on SubscribeCompleted/AlarmSubscribeCompleted; drop stale completions and release captured-adapter handles (arch-review 2026-08-19 P2-1 High)
An in-flight subscribe launched against adapter generation N can take up to
SeedOverallTimeout (120s) to answer. If the adapter is swapped in that window
(failover, or the row-97 in-place reconfigure), the completion was applied
unconditionally: it stored a dead session's handle under the tag key, so the
LIVE completion for the same tag read as a duplicate and had its working
monitored item released (tag resolved forever, no data); it re-stamped the old
endpoint's seed values with the CURRENT generation, bypassing the stale-data
guard; and a connection-level failure row from the dead adapter knocked the
healthy new connection back into Reconnecting. The alarm twin released the new
live alarm feed the same way.

Both completions now carry the generation AND the adapter instance they ran
against, and both handlers drop a completion whose generation no longer
matches - no handle store, no seed application, no per-tag or connection-level
failure processing, no duplicate-release logic. Handles the dropped completion
did create are released best-effort against the CAPTURED adapter (handles are
adapter-scoped; MxGateway's are plain ints that collide across sessions), and
the existing release sites in both handlers were switched to the message's
adapter for the same reason. The in-flight markers are deliberately left alone
(ReSubscribeAll/ReSubscribeAllAlarms clear them wholesale and may already have
re-registered the tag/source), and the requester gets a failure reply so its
retry timer re-sends.

Tests: DataConnectionStaleCompletionTests - stale handle not stored / live item
not released, release lands on the old adapter only, seed values not delivered,
stale connection-level failure does not re-enter Reconnecting, stale alarm
completion does not release the live feed. All five fail against the unfixed
handlers.
2026-08-19 13:54:45 -04:00
Joseph Doherty 7c1268d85c feat(dcl+siteruntime): reconfigure a LIVE data connection in place — register row 97
`DataConnectionManagerActor.HandleCreateConnection` is create-only (warns and
returns for a name it already holds), so `EnsureDclConnection`'s documented
"a changed config re-issues the create so the DCL adopts it" was never true on
ANY node: a corrected endpoint/credential/backup/failover-count took effect only
when the connection was next built from scratch (node restart, singleton
failover, remove-then-re-add), while the DM's hash cache recorded it as applied.
Rows 89/90 made that honest with a Warning; this closes it.

New `ReconfigureConnectionCommand` (Commons, same shape as the create):

- `DeploymentManagerActor.EnsureDclConnection` now has three outcomes off its one
  per-name hash slot — unchanged -> nothing at all, new -> create, CHANGED ->
  reconfigure — and logs "Reconfigured DCL connection {Connection}
  (protocol={Protocol}) in place" at Information in place of the old Warning. The
  winner-resolution / arbitration / tombstone logic is untouched; only what
  happens after a change is detected changed.
- `DataConnectionManagerActor` FORWARDS the command to the owning connection
  actor, falling back to a create for a name it does not hold, so the command is
  safe whatever the manager's state.
- `DataConnectionActor` handles it in ALL THREE states and never stashes it — a
  connection pointed at a wrong or dead endpoint lives in Connecting/Reconnecting,
  which is exactly when a correction arrives; stashed it would wait on the broken
  configuration forever. Handling replaces protocol/primary/backup/failover-count,
  re-arms endpoint selection to Primary (the new config's primary is the intent,
  whatever the old config had failed over to), and calls the new shared
  `SwapAdapter` helper — now used by both failover sites too, so the swap exists
  once: unhook + fire-and-forget dispose -> _factory.Create -> rewire -> bump
  _adapterGeneration LAST. `BecomeReconnecting(afterReconfigure: true)` then
  reconnects immediately (StartSingleTimer replaces any armed reconnect, so no
  racing attempts) with the unstable-disconnect accounting and failover check
  suppressed — the link was dropped on purpose, and counting it as an unstable
  cycle could trip a failover onto the NEW backup before the new primary had been
  tried once. ReSubscribeAll/ReSubscribeAllAlarms then re-issue everything from
  the untouched subscription registries. Idempotent: a reconfigure carrying the
  configuration already in force is a no-op.

Stop-and-recreate was rejected as destructive: subscriptions live inside
DataConnectionActor and InstanceActor cancels its subscribe-retry timer on first
success, so a rebuilt actor would have no subscribers and nothing would ever
re-subscribe.

Tests: new DataConnectionReconfigureTests (7; 5 fail / 2 pass against a
behavioural revert). DclConnectionArbitrationTests gains two row-97 tests and its
CDC-arrival test now asserts the second push is a reconfigure; its ping-pong
guard also asserts zero reconfigures, since a flip would now show up there.
SiteRuntime-010 renamed to ..._ReissuesReconfigureCommand. 3 fail against a
reverted EnsureDclConnection. DataConnectionLayer.Tests 327/327,
SiteRuntime.Tests 643/643, solution build 0 warnings.

Docs: Component-DataConnectionLayer.md gains an "In-place reconfiguration"
section under Endpoint Redundancy; Component-SiteRuntime.md, and the
docs/components/ mirrors, updated; the arbitration decision memo gains an
appended §9 postscript resolving its residual 1 (residuals 2 and 3 stay open).
2026-08-17 06:19:13 -04:00
Joseph Doherty 230c841d35 merge: tag-resolution counts fixed on first subscribe (register row 55) — HandleSubscribeCompleted was the missing fourth UpdateTagResolution push site, so a perfectly healthy connection reported 0/0 forever 2026-08-15 17:56:14 -04:00
Joseph Doherty b5f120c370 feat(observability): honest stream-subscriber name + real data-connection gauges (row 54)
scadabridge_site_connection_up never counted data connections. It counts open
central->site gRPC subscriber streams (Debug View + the site-wide alarm feed),
so it correctly reads 0 on a healthy site nobody is watching — and the name
invited reading it as device health. That misreading has already cost a live
debugging session: register row 48's 'connection_up is 0 on all six site
nodes' was healthy steady state, not the fault it was diagnosed as.

Two halves, per the row:

RENAME. scadabridge.site.connection.up -> scadabridge.site.stream.subscribers.active
(helpers SiteConnectionOpened/Closed -> SiteStreamSubscriberOpened/Closed), and
the instrument gains the unit:"1" the other gauges already carried. Every
reference updated: the gRPC server, both test suites, Component-Communication.md,
components/Commons.md, docker/README.md and docker/seed-live-probe.sh. A test
now pins the new name AND asserts the old one is gone, so it cannot creep back.

NEW. scadabridge.site.data_connections.connected / .total — the first exported
data-connection signal (the state existed on the health report and in the CLI,
but never as a metric). connected < total is the alert condition; neither
number alone separates 'a device is down' from 'nothing is configured', which
is why the denominator ships with the numerator.

Sourcing is deliberate on two counts. It is fed by the DCL at its four state
transitions rather than derived from the health report, so the metric survives
a dead report pipeline — the exact failure the 'metrics stale' flag exists to
catch, and a derived gauge would go blind at the same moment. And it uses a
static registry reached through ScadaBridgeTelemetry (the SiteConnectionOpened
precedent) rather than a DI-injected holder: the DCL actors already take
ISiteHealthCollector through their constructors, and threading a second
dependency through both would ripple into every test that builds them. It also
keeps SiteHealthCollector untouched, which matters right now — another agent is
concurrently editing that file for the tag-resolution path.

Removal is wired too: an undeployed connection leaves the registry, so it stops
counting toward the total instead of latching connected < total on forever.

Both gauges read 0 on the standby (connections open on the active node only) —
healthy, documented, and called out in the docs so it does not become the next
site_connection_up.

No ObservedMeters allowlist change: all three instruments ride the existing
ZB.MOM.WW.ScadaBridge meter. (An unlisted meter exports nothing, silently.)

Tests: Commons 711 passed (9 new, delta-based against a baseline with unique
per-test connection names, so they do not inherit the register row 32
QueueDepthGaugeTests static-state flake); Communication 717; DCL 319.
2026-08-15 12:53:12 -04:00
Joseph Doherty 5da27e05c7 fix(dcl): push tag-resolution counts on first subscribe (register row 55)
A site health report showed tagResolutionCounts 0/0 for a connection whose
dataConnectionTagQuality on the SAME report read good:2 — reproduced live on
the docker rig against site-a's rig-probe-1 instance (2 Good OPC UA tags on
"OPC PLC Simulator"), on the ACTIVE node's own report.

Not a standby-shadowing or keying/removal problem, and not a serialization
problem: both dictionaries live on one collector instance on one node, and the
CentralControlDtoMapper round-trip is correct in both directions. The actor's
own derived counts (TotalSubscribedTagCount / ResolvedTagCount) were right the
whole time — GetHealthReport replied 2/2.

Root cause: HandleSubscribeCompleted — the path that registers tags on a first,
healthy subscribe — mutated _instancesByTag and _subscriptionIds but never
pushed to ISiteHealthCollector. The only pushes were BecomeConnected's (fires
before any instance subscribes, so its 0/0 is legitimate), the batch apply
(reconnect re-subscribe / resolution probe) and unsubscribe (teardown). A
connection whose tags all resolve first time reaches none of those, and
ScheduleTagResolutionRetry cancels the retry timer outright when nothing is
unresolved — so the connect-time 0/0 was never superseded and stood forever.

The blind spot was therefore worst on a perfectly healthy connection, which is
exactly when the "device still booting / tag path unresolved" diagnostic should
read clean rather than empty. Any reconnect masked it (the batch path pushes),
which is why it presented only on a clean first deploy.

Fix: push the derived counts at the end of the first-subscribe apply, mirroring
the existing push site in HandleBatchSubscribeCompleted. No semantic change to
the null/no-data convention — the map entry already existed, its values were
simply stale zeros.

Tests: fail-before regression test pins the exact mechanism (NSubstitute records
a single UpdateTagResolution(name, 0, 0) pre-fix while the actor reports 2/2).
DCL 320, HealthMonitoring 97, SiteRuntime 605, Communication 717 all green;
slnx builds clean.

Docs: Component-DataConnectionLayer.md said the counts were "derived at report
time", which implies a pull that cannot go stale and papered over this bug.
Corrected to state they are pushed, name the four push sites, and record why a
healthy connection was the worst case.
2026-08-15 12:46:37 -04:00
Joseph Doherty 491df111ea fix(dcl): derive tag-resolution health counts from per-tag authoritative state
Closes arch-review remediation residual #1 (DCL unsubscribe-during-reconnect
count staleness).

DataConnectionActor tracked TotalSubscribedTags/ResolvedTags as two int fields
incremented and decremented at five independent sites. ReSubscribeAll clears the
very maps those decrements key off (_subscriptionIds, _unresolvedTags) while
deliberately preserving _subscriptionsByInstance, so an unsubscribe landing
inside a reconnect window matched NEITHER decrement branch: the total leaked +1
per subscribe/reconnect/unsubscribe churn cycle, permanently and cumulatively.
The 37f13e2e discard gate stopped the orphan-handle half of that race; it could
not stop the counters drifting, because they were state of their own.

Both counts are now DERIVED at report time from the authoritative per-tag
collections, which makes the drift unrepresentable rather than merely guarded:

  total    = _instancesByTag.Count   (the per-tag counted set the residual
                                      called for — distinct tags with at least
                                      one subscribing instance)
  resolved = _subscriptionIds.Count  (tags for which the adapter holds a handle)

Two semantic corrections fall out of the derivation:

- A tag whose subscribe failed at CONNECTION level now counts toward the total.
  It was excluded before, yet the reconnect re-subscribe re-issued it from
  _subscriptionsByInstance and booked it as resolved — resolved above total, and
  a total driven negative by the eventual unsubscribe.
- _tagSubscriberCount is deleted. It duplicated _instancesByTag exactly, so
  HandleUnsubscribe's last-subscriber test is now "did UnindexTag drop the key?"
  — still O(1), with no parallel count that can disagree about when a handle is
  released. The subscribe-success promotion split (fresh vs. unresolved→resolved)
  also goes: it existed only to pick which scalar to bump; set sizes get
  DataConnectionLayer-020's double-count cases right for free.

Behavior is otherwise unchanged — same logging, same handle release, same
unresolved-tag probing, same in-flight-unsubscribe discard semantics (the long
comment block there is updated for the mechanics that changed).

Tests: five TagResolutionCounts_* cases in DataConnectionActorBatchTests
covering the churn repro (3 cycles), a shared tag losing one instance mid
reconnect, connection-level failure then recovery, plain subscribe/unsubscribe
cycles, and a completed reconnect re-subscribe. Verified failing against the
pre-fix actor (churn: total 1 not 0; connection-level: total 0 not 1) and
passing after. Full DCL suite 319/319; solution builds with 0 warnings.

Docs: Component-DataConnectionLayer.md health-reporting section describes the
derived counts; residuals register item 1 marked RESOLVED.
2026-08-15 02:05:35 -04:00
Joseph Doherty 37f13e2eaa fix(dcl): discard in-flight subscribe results for unsubscribed tags; release the orphaned handle 2026-08-14 23:25:48 -04:00
Joseph Doherty d15c5f02ea perf(dcl): batch subscribe/read/write seam, bounded reconnect, sharded subscriptions 2026-08-14 21:14:04 -04:00
Joseph Doherty 01bcca992c feat(alarms): thread an additive AckTime through the native-alarm mirror
MES alarm-status API §6.4 (docs/plans/2026-06-30-mes-alarm-status-api.md,
Phase 1 task 1). MES needs a real AckDT for a triggered alarm, and the mirror
carried acked-vs-unacked but never WHEN. AckTime now rides the whole path:
DCL transition -> AlarmStateChanged -> gRPC AlarmStateUpdate -> site SQLite.

Stamping rule, identical on both protocols: non-null ONLY while the condition
is active AND acknowledged. That single predicate yields all three required
behaviours -- null while unacked, cleared on re-raise (a re-raise arrives
unacknowledged), and no phantom ack on a return-to-normal. The last one is
load-bearing for MxGateway, which maps INACTIVE to Acknowledged = true; without
the active check every clear would claim an ack the system never observed.

Provenance is honest, never fabricated:
  - OPC UA A&C supplies a TRUE ack instant, so we now select it:
    AcknowledgeableConditionType/AckedState/TransitionTime at SelectClause
    index 18, APPENDED so the positional reads at 0-17 keep their meaning.
    Servers that omit the field fall back to the event's own Time.
  - MxAccess Gateway supplies none, so the ack transition's own timestamp is
    used -- accurate to when the system SAW the ack. An ACTIVE_ACKED
    re-subscribe snapshot restores one from LastTransitionTimestamp rather
    than dropping it.
The decision lives in pure mappers (Opc/Mx AlarmMapper.DeriveAckTime), so it is
unit-tested with no live server or gateway.

Additive-only throughout: init-only property on AlarmStateChanged, trailing
optional positional on NativeAlarmTransition (all 14-arg call sites untouched),
proto field 24 (never reusing a number) regenerated via docker/regen-proto.sh
sitestream with the csproj diff verified empty.

Persistence rides native_alarm_state's existing metadata_json blob rather than
a new column -- deliberately. That table is RegisterReplicated in
SiteLocalDbSetup and LocalDb builds its CDC triggers from the column list at
registration time, so an additive JSON property changes no schema, no triggers
and no replication contract; metadata_json is exactly the extension point UA4
introduced for this. Rows written before the field deserialize it as null.

Tests: 4 OPC UA + 6 MxGateway mapper cases, 3 NativeAlarmActor (emit,
failover rehydrate, pre-AckTime row), 1 proto round-trip incl. the null case,
4 Commons additive/back-compat. The OPC UA SelectClause count lock-in moves
18 -> 19 with an index-18 assertion -- intended, the clause is appended, which
is precisely what that guard exists to make visible.
2026-08-01 13:12:04 -04:00
Joseph Doherty 86d129de6c fix(dcl): harden endpoint host-rewrite — IPv6 brackets + portless URLs
Code review of a1abbff7 found two edge cases: a discovery/advertised URL with no
explicit port emitted a malformed ':-1' (opc.tcp has no Uri default port), and an
IPv6 literal host could lose/double its brackets. Omit the port when neither URL
carries one; bracket an IPv6 host only when missing. +4 tests (12 total).
2026-07-23 16:58:44 -04:00
Joseph Doherty a1abbff760 fix(dcl): rewrite advertised OPC UA endpoint host to the reachable one
An OPC UA server advertises its base address from its own config, not the route
the client took — commonly a 0.0.0.0 wildcard bind or an internal container/NAT
hostname. The OPC Foundation session dials EndpointDescription.EndpointUrl
verbatim, so a 0.0.0.0 advertisement resolved to the client's own loopback and
the connect failed. RealOpcUaClient now swaps the advertised authority for the
reachable host/port (ConnectAsync + VerifyEndpointAsync), preserving scheme+path;
no-op when already reachable. Surfaced live-gating OtOpcUa v3 (#14).
2026-07-23 16:43:45 -04:00
Joseph Doherty 97afa84fcd docs(dcl): sweep ns= examples to durable nsu= form (v3 cutover #14) 2026-07-23 15:17:13 -04:00
Joseph Doherty 3e84eee195 fix(dcl): route native OPC UA alarms by binding identity, not event name
A native OPC UA alarm source's SourceReference has to be two things at once:
it is parsed as a NodeId to open the monitored item, and matched as a plain-name
prefix against the event's SourceName to route the transition to an instance. No
string is both, so a NodeId-form binding subscribed correctly and then silently
dropped every transition — "pymodbus/plc/HR200".StartsWith("nsu=...;s=pymodbus/plc/HR200")
is false. Only the empty (Server-object) binding worked, because StartsWith("")
matches everything, which is why the sole live smoke test never caught it.

Each OPC UA alarm feed is opened for exactly one binding, so every transition on
it belongs to that binding. The adapter now tags each transition's routing
identity (SourceObjectReference) with the binding string verbatim via the pure
OpcUaAlarmMapper.BuildIdentity, making DataConnectionActor's routing key an exact
match regardless of whether the binding is stored as ns=<index> or the durable
nsu=<uri> form. The Server-object aggregate feed keeps an empty routing identity,
so it reaches only "mirror everything" subscribers and never leaks into a
specific-node binding. The per-condition SourceReference key stays the readable
SourceName.ConditionName, so persistence and display are unchanged, and MxGateway
is untouched — its bindings are names and its mapper already emits matching names.

Unblocked by lmxopcua#473 (OtOpcUa now populates SourceNode/SourceName/EventType
on conditions); SourceName is the RawPath, so the per-condition key is unique.
Live end-to-end verification against native alarms still needs a v3 rig.

Fixes: Gitea #17
2026-07-17 15:07:43 -04:00
Joseph Doherty 30196d1ab8 feat(dcl): bind OPC UA nodes by namespace URI, not baked index
A stored ns=<index> reference is only meaningful against one server's namespace
table. A server that adds, removes or reorders a namespace silently re-points
every binding: best case BadNodeIdUnknown, worst case the index now names a
different namespace holding a colliding identifier and the binding resolves to
the wrong node with Good quality. Nothing could detect that, because ScadaBridge
stored no namespace URI anywhere.

OtOpcUa v3.0 makes this concrete: v2's sole custom namespace and v3's raw
namespace both sit at index 2, so v2-era bindings resolve against v3 without
error while meaning something else entirely.

Adds OpcUaNodeReference as the single translation seam between stored references
and the wire. Resolve() accepts both ns=<index>;s=<id> (existing bindings, which
keep working unchanged) and the durable nsu=<uri>;s=<id>, mapping the URI to the
live index at use time; it is wired into every parse site — subscribe, read,
write, alarm-subscribe and browse. An unpublished URI now throws naming the URI
rather than binding to whatever occupies that index, and a svr= reference to
another server is rejected instead of being resolved against the wrong address
space.

The browser emits ToDurable(), so what the picker shows is what gets stored and
newly-authored bindings are index-proof from the start. That also closes a
round-trip gap: browse previously emitted ExpandedNodeId.ToString(), which for a
URI- or server-index-carrying reference produced a string NodeId.Parse could not
read back — the same method already resolved it correctly 57 lines later.

Bindings stored before this change keep their ns= form and keep working; they are
only as durable as the server's namespace order. Re-authoring against the picker
is what makes them durable, and that re-bind still needs a live v3 rig.

Refs: Gitea #14
2026-07-17 15:07:43 -04:00
Joseph Doherty 128f159692 feat(secrets): resolve MxGateway ApiKey secret: refs at connect time (ScadaBridge G-3 T9) 2026-07-16 15:37:01 -04:00
Joseph Doherty ccee558ca7 merge(r2): r2-plan08
# Conflicts:
#	src/ZB.MOM.WW.ScadaBridge.Communication/CommunicationOptionsValidator.cs
2026-07-13 11:10:15 -04:00
Joseph Doherty 7943d73e71 fix(options): canonicalize Communication/DataConnection config sections to ScadaBridge:*; drop the duplicate Host bindings that were masking the drift (plan R2-08 T9, arch-review 08r2 NF8) 2026-07-13 10:58:28 -04:00
Joseph Doherty f25812fc7c fix(dcl): stale MxGateway event-loop fault on a cancelled token no longer flaps the fresh connection (plan R2-03 T1) 2026-07-13 09:45:20 -04:00
Joseph Doherty 5a878b78d4 docs(xml): fill missing XML doc comments + strip task-tracking refs across src (fixdocs)
Add missing <summary>/<param>/<returns>/<typeparam> tags and switch
interface implementations to <inheritdoc/> across 106 files; strip
project bookkeeping identifiers (Task NN, #05-TNN, PLAN-04, StoreAndForward-0NN)
from shipped code comments while preserving the descriptive rationale.
Comment-only: zero code-logic lines changed; solution builds 0/0.

Claude-Session: https://claude.ai/code/session_01MtdgwpEeCUn6cUA5f1LMPj
2026-07-10 08:23:56 -04:00