Composable StaleTagMonitor class in Commons fires a Stale event when no
value is received within a configurable max silence period. Integrated
into both LmxProxyDataConnection and OpcUaDataConnection adapters via
optional HeartbeatTagPath/HeartbeatMaxSilence connection config keys.
When stale, the adapter fires Disconnected triggering the standard
reconnect cycle. 10 unit tests cover timer behavior.
- Add JoeAppEngine folder to OPC UA nodes.json (BTCS, AlarmCntsBySeverity, Scheduler/ScanTime)
- Fix DataConnectionActor: capture Self in PreStart for use from non-actor threads,
preventing Self.Tell failure in Disconnected event handler
- Implement InstanceActor.HandleConnectionQualityChanged to mark attributes Bad on disconnect
- Fix LmxFakeProxy TagMapper to serialize arrays as JSON instead of "System.Int32[]"
- Allow DataType and DataSourceReference updates in TemplateService.UpdateAttributeAsync
- Update test_infra_opcua.md with JoeAppEngine documentation
- Add connection binding UI to Instances page (per-attribute and bulk assign)
- FlatteningService populates Connections dict from bound data connections
- Real OPC UA client using OPC Foundation SDK for live tag subscriptions
- DataConnectionFactory uses RealOpcUaClientFactory by default
- OpcUaDataConnection supports both "endpoint" and "EndpointUrl" config keys