Script file access (design docs/plans/2026-09-28-script-file-access-design.md): Files.ReadTextAsync /
ReadLinesAsync / ExistsAsync on site ScriptGlobals (+ Instance.Files), backed by the site-singleton
ScriptFileReader. The one host-mediated exception to the System.IO ban - scripts still never name a
System.IO type. OFF by default: ScadaBridge:SiteRuntime:ScriptFileAccess:AllowedRoots (empty = every call
throws Disabled) + MaxFileBytes (1 MiB, validated 1..64 MiB, roots must be absolute). Guard: fully
qualified, no device paths / ADS, canonical path strictly inside a root (directory-boundary match), no
reparse point on the file or any directory below the root, size cap before and during the read.
Errors are one Commons type, ScriptFileAccessException(+ScriptFileAccessFailure); Commons.Types.Scripts
joins the default script imports on every surface so it binds by short name. Mirrored on
ScriptCompileSurface (CompileFiles, parity-pinned) and the Test Run sandbox (binds, refuses Disabled).
Inbound (central) scripts do not get it.
Rig: docker/recipes (sample RecipeValueName,RecipeValue files incl. an invalid one) bind-mounted
read-only at /app/recipes on both site-a nodes with AllowedRoots [/app/recipes]. The TestMesMachine
SimDelmiaRecipe simulator now reads + parses the downloaded file, converts each value to its recipe tag's
type and loads it all-or-nothing (14 new TestDelmiaReceiver attributes); verify-mes-test-machine.sh
group A covers accept / re-download / invalid lines / NotFound / OutsideAllowedRoots, VERIFY_GROUPS
selects groups (rig: AD).
vd03 (DEV) upgraded 2b9a7c3c -> fe89363b via the deployment-only winrm channel: COPY_ONLY backup,
55->57 delta script (AddAlarmMesReportable, AddSiteArtifactRevision), ~53 s window, snapshots
identical to baseline, artifacts deployed. Register row 126 now covers the QA pair only.
docker/seed-mes-test-machine.sh (idempotent) builds a standalone TestMesMachine base template -
Left/Right TestMESReceiver + TestDelmiaReceiver (prod attribute names, STATIC), computed alarms
with IsMesReportable, CvdReactor-compatible MesMoveIn/MesMoveOut/ProcessRecipeDownload/AlarmStatus
scripts ported to SetAsync+WaitAsync, and Galaxy-side simulators with reject/no-response knobs -
plus instances SBTEST01/02 and the SimpleAlarmStatusRequest (was a stub) / AlarmStatusRequest
inbound methods in the legacy /mes/(simple)alarmstatus shapes, resolving machines through BTDB.
BTDB rows SBTEST01=990001 / SBTEST02=990002 added on vd03.
docker/verify-mes-test-machine.sh drives the real inbound methods via flow-debug: PASS 25/25.
Task 13/14. seed-mes-alarm-demo.sh builds a template whose three computed alarms differ in
how they acquire the flag (template --mes-reportable, nothing, instance override over a
template false), a site Call script projecting them through Alarms.CurrentAsync() /
MesReportableAsync(), and two inbound methods + a scoped API key. Idempotent by name lookup.
verify-mes-alarm-demo.sh drives the real inbound HTTP surface: PASS 14/14 on the docker rig
(migration 20260911135501_AddAlarmMesReportable applied at boot). Playwright
AlarmOverride_MesReportable_RoundTrips passed. Results + the facts the gate established are
in design doc section 8.
Claude-Session: https://claude.ai/code/session_01Y5ef34iUUMjmwnMpL9xgmB
Moves the legacy BTDB MachineAlarm.FlaggedForMES lookup onto TemplateAlarm.IsMesReportable
(instance-overridable), surfaces it as ScriptAlarm.IsMesReportable / Alarms.MesReportableAsync(),
and adds an AlarmStatus inbound method demo on the docker rig. Native alarms stay on the
severity band (no per-alarm row).
Claude-Session: https://claude.ai/code/session_01Y5ef34iUUMjmwnMpL9xgmB
A null resetValue encoded to null, which wrote an empty string and then handed the
waiter a null target (= any change), fast-pathing on the stale cache and reinstating
the race the overload exists to close. The context parameter is now non-nullable and
the accessor throws ArgumentException before any write. Also: additive-timeout note on
all surfaces, batch-failure message no longer names the bool overload, and the
error-message/batch-failure branches are pinned.
Claude-Session: https://claude.ai/code/session_01XPsuy2ZZ5Gbyfpt8PrK5BV
The MES/Delmia handshake fast-paths on the previous run's cached CompleteFlag
because the reset write has not echoed back before the wait registers. An
edge-triggered wait is rejected (a subscription can swallow the reset when the
device flips inside one sampling interval); the fix encodes the reset leg inside
a new WriteBatchAndWaitAsync overload that observes the reset echo before writing
the trigger and returns a phase-aware HandshakeResult.
Claude-Session: https://claude.ai/code/session_01XPsuy2ZZ5Gbyfpt8PrK5BV
Second slice of the 2026-09-09 whole-system review remediation
(docs/plans/2026-09-09-arch-review.md §10), on top of the High slice 146a1323.
Runtime/devices: SR-2 alarm on-trigger integration scope; SR-3 correlated NativeAlarmActor
subscribe retry; SR-4 immutable audited DB target; SR-5 ordered InstanceActor stop/flush;
SR-12 rehydration fence; SR-13 S&F gate recheck per delivery; DC-4 no OPC UA security
downgrade; DC-5 alarm snapshot for every new subscriber; ORCH-1 sync-dispose joins the pump.
Management/UI: MG-2 site scope on audit tree + Flow Debugger Replay; MG-3 stale-probe memo
removed; MG-4 server-owned bulk-deploy deadline; UI-5 sandbox runs in a killable child
process (new CentralUI.SandboxWorker project); UI-14 bounded sandbox output/IPC.
Edge/audit: EI-1 relay audit ownership; EI-2 SkipBodyCapture suppresses error text; EI-3/EI-11
error-field redaction + caps; EI-4 single relay deadline, pre-execution-only retry; EI-5
authenticated relay provenance; EI-10 body cap before audit read.
Persistence/contracts: DL-1 global Instance.UniqueName unique index + conflict translation;
DL-2 DataConnection protocol config encrypted at rest (migration
20260909203046_EnforceGlobalInstanceNamesAndProtectProtocolConfiguration — coordinated
central upgrade, old binaries cannot read protected rows); DL-3 bounded Replay paging;
DL-6 cross-site Overwrite of a deployed instance rejected; XC-4 proto descriptor contract test.
Config/hygiene: XC-1 central listener isolation by local port; XC-2/XC-3 inert SMTP + cron
keys removed from rig settings; CM-2 env2 bootstrap guard enabled; DC-6 deploy site exit code;
DC-7 notifier retries only explicit standby rejection; XC-5 ClusterClient purged from docs.
Gates recorded in the report: build 0/0, 9 397 passed / 0 failed, rig redeployed on all
eight nodes with the migration applied. 46 Low findings remain open.
Replaces the value-change (site/instance/attribute) entry with a script picker.
ValueChange/Conditional scripts keep the write-and-poll path with the attribute
derived from the trigger config; every other kind is invoked directly through the
traced RouteToCall path with a parameter form from the script's ParameterDefinitions.
New additive FlowDebugRunScriptCommand; run-value-change stays as the CLI escape hatch.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
Code review of the merged arch-review remediation (Tasks 1-13) found four items.
1. FlowDebugRunner returned its OWN synthesized rows un-redacted. RunMethodAsync's
inbound row and RunValueChangeAsync's root row were handed to WriteCentralAsync
(whose writer redacts a private copy) and then put RAW into the returned Events —
so a Live run's caller saw the unfiltered row while Replay of the same execution
showed the redacted one, defeating F1's "Live shows what Replay reads back". Both
methods now resolve IAuditRedactor once per run and place the filtered copy into
the result (including the early-return path on a failed attribute write); the raw
row still reaches the writer, which redacts itself.
2. FlowGraphBuilder's spawner search degenerated to "the last step of the parent".
Since executions are ordered as contiguous blocks, position[p] < childPosition
holds for EVERY parent step, so a run shaped ScriptRun -> Write(A) -> Wait ->
Write(B) whose Write(A) fired the cascade drew the Spawn edge from Write(B). New
rule, in order: (a) the last non-async, non-Response parent step occurring at or
before the child's first step — parent and child of a trigger cascade share the
site clock, so this picks the write that actually fired it; (b) the position rule
as fallback, which is the mixed-clock case F5 was written for (a child clock
behind its parent's, where no parent step satisfies (a)); (c) parentChain[0].
The class remark's stale "Replay order is unchanged" claim is replaced with what
actually happens to a central Database.* call made after Route.To().Call.
3. FlowTraceCollector's byte budget counts UTF-16 chars of DetailsJson only, so
"well under the 4 MB gRPC default" overstated it. Documented honestly: ~1 MB of
UTF-8 for ASCII payloads, ~3 MB worst case for non-ASCII, both under 4 MB before
framing — and raise it only against a real serialized-size measurement.
4. CLI --timeout-seconds help + README row now say the management endpoint caps
flow-debug run-method at ManagementService:LongRunningCommandTimeout (default
5 min), so a larger client value still 504s at the server's ceiling.
Deferred-work register rows 112 (site-side inline trace truncation is invisible to
the operator — needs a proto field) and 113 (the F2 method-entry site scope gates
routed traffic only; ApiMethods have no site affinity to scope against) record what
this review deliberately did not fix.
Tests: FlowGraphBuilderTests gains the same-clock Write(A)/Wait/Write(B) cascade
(red before the rule change, and the clock-behind test still passes on rule (b));
FlowDebugRunnerTests extends the redactor test to the inbound row and adds two
value-change cases (settled poll, failed write). Commons 793, ManagementService 615,
CentralUI 1264, CLI 462 — all green.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
The Flow Debugger design doc still described the pre-remediation shape: a
debug-stream subscription for the value-change entry, Deployer everywhere, an
unredacted inline trace copy and "~7 audit rows per call". Reconciled with what
shipped on this branch (Tasks 1-12):
- design D6 / §5.4 / §9 / §10: RequireFlowDebugger page policy with Deployer-only
execution (F3), the PullTraceEvents polling path with AttributeValueUpdate
fields 7/8 recorded as RESERVED and unconsumed (F12), the redacting + byte-
capped shared FlowTraceCollector (F1), route-time site scope (F2), the derived
client waits (F4), the 7-10 row estimate, the doubled central audit write per
routed call, and the inbound-row-after-the-run ordering.
- sitestream.proto: fields 7/8 marked reserved-but-populated, numbers not to be
reused (comment only; no regeneration needed).
- Component-InboundAPI: SkipBodyCapture on the RouteCall row (F11),
SchemaRefResolver's public visibility, WithSiteScope / SITE_SCOPE_DENIED (F2),
Replay's wider role set (F3).
- Component-CentralUI: page policy vs Deployer-only controls (F3), route-time
site scope (F2), client wait derivation (F4).
- "7-10 audit rows per call (3 of them trace-only)" everywhere the estimate is
quoted: the method form, both CLI --trace-all-calls help strings, the CLI
README, the ApiMethod entity doc, the manual migration script and the two
Flow Debugger plans.
- arch-review doc: new §7 Resolution listing F1-F13 with the fixing commit, plus
the tracking-store test race fixed alongside them (86451382).
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
Full review of the Flow Debugger commit range (v1.0, v1.1 outbound calls, v1.2 follow-ups,
outcome-merge fix, two perf commits). Also records the exact 11 role-negative Playwright
tests that cannot pass on the login-disabled rig in the cluster-ops skill.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29