Joseph Doherty 952db02aab fix(cluster): leader-auto-down restarts a node its peer has shut out; higher address restarts when both are (#132)
A node frozen past failure detection + StableAfter, or both sides of a partition
that heals after each downed the other, used to stay a second active node until an
operator restarted one: the peer quarantines the removed UID and Akka.Cluster
1.5.62 never acts on ThisActorSystemQuarantinedEvent.

ShutOutRestart (child of the LeaderAutoDown downing actor; opt-out via
ScadaBridge:Cluster:LeaderAutoDown:RestartWhenShutOut, default on for
leader-auto-down only) watches two signals:
- S1 ThisActorSystemQuarantinedEvent: the peer quarantined this node. If the peer
  is still a live member here, only this side can be shut out -> restart now.
- S2 AssociationErrorEvent 'has a UID that has been quarantined': the peer still
  runs the incarnation this node removed. A healed partition yields only S2, on
  both sides. Wait ShutOutGrace (60s) for a frozen peer to restart itself, then
  tiebreak.
Tiebreak: the higher address (Akka Member.AddressOrdering) restarts, the lower
stays and restarts only if still split one grace later. Removed peers are probed
(Identify, 5s -> 60s back-off) since nothing else contacts them after mutual
removal. Restart = Cluster.Down(self) -> existing self-down path.

The Host now exits 75 after an unplanned ActorSystem termination (and sets it on
the Windows service before it reports stopped): SCM recovery with failureflag 1
only restarts a service that stops with a non-zero code, and the watchdog used
to exit 0. Shipped default strategy stays auto-down.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 21:26:16 -05:00
Joseph Doherty 456c6659e7 feat(cluster): leader-auto-down decision logging + cold-start/flapping/partition/switch-off scenarios (ScadaBridge#106)
Every downing decision of LeaderAutoDowningProvider is now logged under a
[leader-auto-down] prefix: start-up snapshot (leader, window, already-unreachable),
unreachable observed + its window (Warning), skipped because already Down/Exiting,
pending Down cancelled on reachable-again/removed, timed out on a non-leader and kept
pending, leadership gained/lost, and DOWNING (Warning) before Cluster.Down. Akka's own
AutoDown logged only the final Down. Decision semantics are unchanged.

New real two-node scenarios (IntegrationTests/Cluster/LeaderAutoDownScenarioTests),
built from production BuildHocon with self-first seeds:
- both nodes cold-start together -> one cluster, nobody downed past FD + window;
- lone cold start with the peer dead (the down-if-alone cold-recreate shape) stays Up,
  then the peer cold-starts and joins;
- flapping peer via Akka's trttl throttler Blackhole: unreachable shorter than the
  window, repeated past it in total -> never downed; positive control asserts the cuts
  really produced unreachability;
- partition held past the window -> each side downs the other, both stay Up and
  leader (the accepted dual-active trade);
- switch off: auto-down loads AutoDowning, keep-oldest loads SplitBrainResolverProvider,
  only leader-auto-down loads the in-repo provider.
Unit: flapping never downs; a flapping member that finally stays unreachable is downed
exactly once a full window after its LAST unreachable; each decision log line.

Mutation-proved: no timer cancel on reachable -> flap-then-stay unit fails; reachable
ignored -> both unit flapping tests, the cancel-log test and the real-cluster flapping
test fail; DOWNING log dropped -> log test fails; provider never downs -> partition
test fails; auto-down miswired to the new provider -> switch-off theory fails.

Docker failover drill not run (it would rebuild the shared scadabridge:latest image
and reuse the shared rig volumes while another agent works in the repo); filed as
deploy gate ScadaBridge#116. Default remains auto-down.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 04:42:03 -05:00
Joseph Doherty ab561faa43 feat(cluster): opt-in leader-auto-down strategy - in-repo port of Akka AutoDowning (ScadaBridge#106)
Adds LeaderAutoDowningProvider (Host/Actors), a line-for-line port of Akka.NET
1.5.62 AutoDowning/AutoDown/AutoDownBase read from the decompiled assembly: the
leader among the reachable members downs a peer unreachable for StableAfter; a
non-leader records it as pending and downs it on becoming leader; reachable-again
or removed members are forgotten; Down/Exiting members are skipped. Its window is
carried under scadabridge.cluster.leader-auto-down.unreachable-after, so no
deprecated auto-down-unreachable-after key is emitted and Akka's boot-time
"keep-majority will be used instead" warning goes away. DownRemovalMargin reads
akka.cluster.down-removal-margin exactly as AutoDowning does (default off).

New SplitBrainResolverStrategy value "leader-auto-down", wired through BuildHocon
and ClusterOptionsValidator. The default stays "auto-down"; auto-down and
keep-oldest HOCON is byte-identical to before. Placed in Host, not
ClusterInfrastructure, per the Code Placement rule (ClusterInfrastructure stays
Akka-free).

Tests: HOCON + validator units; LeaderAutoDownTests ports Akka's AutoDownSpec
cases (leader-only, pending-on-leader-change, losing leadership, reachable again,
removed, Down/Exiting skipped, single Down per member); LeaderAutoDownFailoverTests
clones SbrFailoverTests' oldest-crash and younger-crash cases on a real two-node
cluster plus a test that Akka actually loaded the provider and its downing actor.
Mutation-checked: a provider that never calls Cluster.Down fails both failover
tests; never-downs, leader-check-dropped, reachable-ignored and pending-not-flushed
mutations each fail the unit tests.

Remaining gate before switching the default: the docker failover drill
(DRILL_MODE=active and standby mode) on leader-auto-down.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 16:46:58 -05:00
Joseph Doherty 3cf97f6dda docs(plans): AutoDowning replacement plan - in-repo DowningProvider reproducing AutoDowning (ScadaBridge#51)
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 16:24:34 -05:00