ScriptCallResult and RouteToCallResponse gain trailing Truncated/LogsTruncated,
filled from the site FlowTraceCollector after Complete(); RouteToCallResponseDto
fields 8/9 carry them (sitecommand regen). FlowDebugRunner ORs them into
FlowDebugRunResult on the script entry, and on the method entry through a new
optional truncation sink on RouteHelper.WithTraceSink (carried through every
With* clone). Previously a site run whose collector dropped rows came back as a
silently short list. Older sites send false.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Second slice of the 2026-09-09 whole-system review remediation
(docs/plans/2026-09-09-arch-review.md §10), on top of the High slice 146a1323.
Runtime/devices: SR-2 alarm on-trigger integration scope; SR-3 correlated NativeAlarmActor
subscribe retry; SR-4 immutable audited DB target; SR-5 ordered InstanceActor stop/flush;
SR-12 rehydration fence; SR-13 S&F gate recheck per delivery; DC-4 no OPC UA security
downgrade; DC-5 alarm snapshot for every new subscriber; ORCH-1 sync-dispose joins the pump.
Management/UI: MG-2 site scope on audit tree + Flow Debugger Replay; MG-3 stale-probe memo
removed; MG-4 server-owned bulk-deploy deadline; UI-5 sandbox runs in a killable child
process (new CentralUI.SandboxWorker project); UI-14 bounded sandbox output/IPC.
Edge/audit: EI-1 relay audit ownership; EI-2 SkipBodyCapture suppresses error text; EI-3/EI-11
error-field redaction + caps; EI-4 single relay deadline, pre-execution-only retry; EI-5
authenticated relay provenance; EI-10 body cap before audit read.
Persistence/contracts: DL-1 global Instance.UniqueName unique index + conflict translation;
DL-2 DataConnection protocol config encrypted at rest (migration
20260909203046_EnforceGlobalInstanceNamesAndProtectProtocolConfiguration — coordinated
central upgrade, old binaries cannot read protected rows); DL-3 bounded Replay paging;
DL-6 cross-site Overwrite of a deployed instance rejected; XC-4 proto descriptor contract test.
Config/hygiene: XC-1 central listener isolation by local port; XC-2/XC-3 inert SMTP + cron
keys removed from rig settings; CM-2 env2 bootstrap guard enabled; DC-6 deploy site exit code;
DC-7 notifier retries only explicit standby rejection; XC-5 ClusterClient purged from docs.
Gates recorded in the report: build 0/0, 9 397 passed / 0 failed, rig redeployed on all
eight nodes with the migration applied. 46 Low findings remain open.
RouteHelper/RouteTarget carry a new captureBodies flag (default true) threaded
through every With* copy, same shape as the site-scope field Task 3 added.
InboundScriptExecutor resolves IOptionsMonitor<AuditLogOptions> from the
per-execution DI scope and looks up PerTargetOverrides[method.Name]?.SkipBodyCapture
exactly as AuditWriteMiddleware.cs:183-187 does for the inbound row, then calls
.WithBodyCapture(!skip) when building the script's Route helper. When set, the
always-on ScriptTrace.RouteCall row omits its request/response summary, so an
operator who suppressed a method's body from the audit log doesn't get it back
via the routed call's arguments (derived from that same body).
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
A method-entry Live run had no site-scope check at all. RunValueChangeAsync
calls EnforceSiteScope on its named instance, but a method run has no single
target site up front — the operator picks a METHOD, and where its script routes
is only known once it runs — so a site-scoped Deployer could reach any site the
method happened to route to.
The scope is therefore pushed into RouteHelper and enforced at route time:
- RouteHelper.WithSiteScope(IReadOnlySet<string>?) carries a set of site
IDENTIFIERS (null = unscoped, the state of every ordinary inbound HTTP
request; an EMPTY set permits nothing, the fail-closed outcome for a scoped
user whose sites no longer exist). Threaded through every With* copy and To().
- The gate lives in RouteTarget.ResolveSiteAsync — the single choke point that
Call, GetAttributes, WaitForAttribute and SetAttributes all pass through — so
it fires BEFORE any site traffic and throws the new RouteSiteScopeException.
- InboundScriptExecutor maps it to error code SITE_SCOPE_DENIED. The type is
InboundAPI's own (that assembly cannot reference ManagementService), and it
derives from InvalidOperationException so base-type callers are unaffected.
- FlowDebugRunner.RunMethodAsync resolves the user's PermittedSiteIds (numeric)
to identifiers via ISiteRepository and converts SITE_SCOPE_DENIED back to
SiteScopeViolationException (-> ManagementUnauthorized), AFTER writing the
inbound audit row so a denied attempt is still recorded against the operator.
Administrators and unscoped users get a null scope and are unaffected, exactly
as EnforceSiteScope treats them. Every contract change is a trailing optional
parameter. Mutation-checked: disabling the gate fails 3 of the 5 new RouteHelper
tests and 1 of the runner tests, while the in-scope/unscoped positives still pass.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
InboundDatabaseHelper gains trailing optional auditWriter / nodeIdentity /
executionId / parentExecutionId / methodName / traceSink parameters; every
QuerySingle/Query/Execute writes one DbOutbound/DbWrite row (Delivered/Failed,
Target = connection name, Actor = 'api:{method}', DurationMs, SQL + parameters
as RequestSummary, Extra in the site's {op, rowsAffected|rowsReturned}
vocabulary, SourceNode) via ICentralAuditWriter — best-effort, never into the
script; the same instance goes to the RouteHelper trace sink first. Closes the
audit-scope gap Component-AuditLog.md already claimed (plan D7). Redaction and
the 8 KB cap apply at write time in the shared redactor, as for site rows.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
Flow Debugger (design 2026-09-05 §5.1/§5.2/§7.1): RouteTarget.Call emits one
ScriptTrace.RouteCall central-direct-write row per routed call (ExecutionId = the inbound
parent, Extra.childExecutionId from the reply, best-effort, never throws into the script)
whether or not the run is traced. WithTrace(bool) stamps Trace on RouteToCallRequest and
RouteToSetAttributesRequest; WithTraceSink hands the row + the reply's inline site events to a
callback so a Live run renders without touching the store. DI supplies ICentralAuditWriter /
INodeIdentityProvider as optional ctor args; new RouteHelper(locator, router) still compiles.
Claude-Session: https://claude.ai/code/session_01GSLkkHKz9JrAtmJjmQK3cP
Phase 4 of the ClusterClient -> gRPC migration deleted the Akka transports
but left the naming behind: `ClusterClientSiteAuditClient` was transport-
agnostic and worked unchanged, so it survived the deletion under a name
that now describes a transport the repo no longer has. Same for a scatter
of doc-comments still framing gRPC as "the new transport" beside an Akka
one that is gone.
Renames it to `SiteCommunicationAuditClient` (and its test file) and
rewrites the stale comments to describe the single transport that exists.
Also tightens CLAUDE.md: drops the self-describing directory listing and
the 27-component enumeration in favour of the non-obvious parts only.
Behaviour-neutral: names and prose only. Recorded as the Phase 4
follow-up in docs/plans/2026-07-22-clusterclient-to-grpc-plan.md.
Remove project bookkeeping citations from shipped code comments across the
solution: hyphenated task IDs (WP-14, StoreAndForward-025), milestone/task/
issue refs (M3, Task 4, Audit Log #23, #21), Bundle X task-bundle labels,
and C/D/K/S/T phase labels.
Comment text only — no code logic, string/log literals, or XML-doc structure
changed. Genuine descriptions are preserved (only the citation is stripped),
and technical lookalikes are retained (UTF-8, SHA-256, T00:00:00, M365,
UTC-5, pre-C4/pre-C5 schema versions). Flagged by the new CommentChecker
TaskReferenceInComment / TrackingReferenceInComment checks plus targeted
grep passes; full solution builds clean, append-only guard tests pass.
Fixes the 8 findings from the 2026-06-24 re-review (commit c42bb485), with a
regression test per Medium finding:
- DataConnectionLayer-029 (Med): HandleAlarmSubscribeCompleted now mirrors the
tag-path re-check — if a feed is already stored for the source, release the
redundant just-created subscription instead of overwriting + leaking the first
one (the double-subscribe window DCL-023 reopened). +regression test.
- InboundAPI-031 (Med): remove WaitForAttribute's local 5s grace backstop (tighter
than the CommunicationService Ask's timeout+IntegrationTimeout round-trip budget,
so a slow-but-valid timed-out 'false' got cancelled into a 500). Link only the
client-abort + explicit caller tokens; the lower layer owns the backstop. +test.
- SiteRuntime-032 (Med): derive the deployed count from an authoritative set of
deployed config names (HashSet) instead of a map-presence-gated int, so deleting
a DISABLED instance decrements correctly (SiteRuntime-029's gate leaked it).
+deploy->disable->delete regression test.
- StoreAndForward-028 (Med): reset _bufferedCount in StopAsync alongside the
register-guard so a same-instance Stop->Start re-seeds from a clean base (no ~2N
gauge double-count). +restart regression test.
- AuditLog-017 (Low): test the OnIngestAsync scope-resolution guard (actor survives,
replies empty, counts the failure) — no longer unpinned.
- CentralUI-037 / ScriptAnalysis-009 / SiteRuntime-033 (Low): doc-comment + spec
fixes (Database-throws in the inbound sandbox; baseReferences param wording;
native-alarm cap return-to-normal + per-condition NativeAlarmDropped eviction).
Targeted suites green: SiteRuntime 5, StoreAndForward 6, InboundAPI 31,
DataConnectionLayer 10, AuditLog 5, ScriptAnalysis 40, CentralUI ScriptAnalysis 52.
Resolves InboundAPI-026/027/028/029 (+ newly-surfaced -030).
- 026: authorize the scoped Database helper in the design doc; SQL-injection
protection is parameter binding (values never concatenated); allow writes via
ExecuteAsync; drop the false 'read-only' claim. Named connections only.
- 027: async ADO.NET end-to-end (no .GetAwaiter().GetResult()); honour the method
deadline token on ExecuteScalarAsync/ExecuteReaderAsync/ExecuteNonQueryAsync +
a CommandTimeout backstop derived from the method timeout.
- 028: negative-path tests (null-gateway, deadline cancellation, parameterization)
+ e2e Database + WaitForAttribute cases through the real endpoint.
- 029: WaitForAttribute is bounded by its WAIT timeout (per-wait CTS + client-abort
+ explicit token), NOT the method deadline (spec §6) — a long wait may outlive the
method timeout; WithRequestAborted threads the raw client-abort token separately.
- 030: Central UI compile-surface mirrors (InboundScriptHost / SandboxInboundScriptHost)
gained the Database member (drifted since the runtime helper was added) so the
authorized async API type-checks at the design-time gate.
Resolve all 622 issues flagged by the enhanced CommentChecker: add missing
<returns> tags (incl. the standard phrasing on non-generic Task methods),
add missing <summary> tags, and replace misused/redundant <inheritdoc/> on
members that override or implement nothing with real documentation.
Documentation-only — no behavior change; solution builds clean.