The Run-inbound-API-method pane rendered one text box per top-level schema
field and coerced the text on the page; an array/object field went through
JsonNode.Parse and, on failure, was SENT AS A STRING, while an empty box was
silently dropped. A required array-of-object parameter (MesMoveOut WorkOrders)
could not be entered at all — QA runs reached the site with "WorkOrders":[].
- The method pane now renders the same shared ParameterValueForm the script
pane uses (typed inputs, nested groups, add/remove list item editors,
$ref:lib: resolution, inline validation), keyed on the method id so a change
of method remounts it. The page keeps ONE value tree and BuildParameters()
serializes it as-is; the flat _inputs / Coerce() / SetInput path is deleted.
- Form | Raw JSON toggle: raw mode is a Monaco json editor for the whole
request body, given the method's root schema for completion, parsed and
schema-validated (InboundApiSchema.Validate) on every edit with the error
inline. Entering raw mode seeds the editor from the tree; leaving it
re-mounts the form over the last valid tree.
- Run is disabled while the form or the raw document is invalid (a required
field left empty disables Run before the first keystroke).
- localStorage per-method entry stores the value tree; on restore it is
validated against the schema and dropped if invalid, which also retires the
pre-#37 flat string-per-field entries.
- ParameterValueForm.ToJsonSchema / JsonElementToObject made internal static
for page reuse.
- Tests: 7 new bUnit tests (WorkOrders array-of-object round-trip to the
RunMethodAsync payload, required list-item gating, invalid raw JSON blocks
Run + shows parse/schema/non-object errors, valid raw JSON sent verbatim and
survives the switch back to the form, method switch resets, persisted tree
restored, legacy flat entry dropped); existing method-pane tests moved to
the form's #param-<field> ids and fill the required field before Run.
Playwright smoke selector moved to #param-Text.
- Docs: design doc, Component-CentralUI.md entry-points bullet, CLAUDE.md.
CentralUI.Tests 1425/1425 green; Playwright project builds.
Claude-Session: https://claude.ai/code/session_01XPsuy2ZZ5Gbyfpt8PrK5BV
The instance row locator used Locator.GetByText scoped to the panel, which
bypasses the [data-test='flow-instance-row'] contract InstancePicker rows
are documented to carry. Match through the data-test attribute instead,
with an exact-text regex since the test only knows the instance name (not
its id, unlike Debug View's tests).
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
Flow Debugger's script-entry instance selection and Debug View's instance
selection both go through the shared InstancePicker combobox now instead of
a flat <select>. Update the tests to type into the {prefix}-input, wait for
the matching {prefix}-row, and click it; keep the <select>-polling helper
for the site select, which is unchanged.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
An ephemeral inbound method (created and deleted through the CLI, with a never-taken
Route.To branch so prediction resolves a route target) is run live in a real browser through
the fixture's /auth/login; the reload test drives the OnAfterRenderAsync localStorage restore
and then proves the page is still interactive. Both fail on the pre-fix image at the
'Predicted' wait (the circuit deadlock) and pass on the fixed one.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29