Comment/XML-doc changes only:
- add summaries to ~10k test methods, fixtures, fakes and helpers
(+ <param> on theories, <returns> on async Task methods,
<inheritdoc/> on interface implementations the checker can resolve)
- strip ~2.6k project-tracking references (WP*, P*-*, row-NN, Task N,
#NN, Component-0NN) from comments, keeping the explanatory text;
reword false positives in comments only
- real docs on fakes implementing BCL/library interfaces
(IDisposable, ILogger, IOptionsMonitor, IAsyncLifetime)
- reword the last 5 src/ false positives (CWE-1236, failures-1,
year-0001, M365)
Only non-comment edits: four one-line nested classes split across lines
so members can carry docs. Build 0 errors / 0 warnings.
P8-8: replace the remaining wall-clock sleep-then-assert instances outside
Communication.Tests' Medium-wave sweep with the same row-40 house pattern —
continuous polling (AssertHoldsFor) for ABSENCE assertions instead of a single
end-of-window sample, which cannot distinguish "stayed quiet throughout" from
"hadn't happened yet when the one sample landed" and cannot catch a value that
flips wrong and back before that sample.
- DataConnectionActorBatchTests: QualityCounters_ArePushedOnTransitionOnly_AndCoalesced
(:206/:214 class) converted to AssertHoldsFor; ResolutionProbes_BackOff...
(:181/:184, a genuine real-time backoff-RATE assertion, not a sync-primitive
stand-in) converted to AssertRoundsWithinWindow, which enforces the ceiling
continuously (fails fast on a no-backoff regression) while the floor still
necessarily waits out the window.
- SiteAlarmLiveCacheServiceTests (:452-454, :470-472): converted to the
project's own AssertHoldsFor (mirrors SiteAlarmAggregatorActorTests', same
assembly).
- StoreAndForwardServiceTests (:891-892): async AssertHoldsForAsync variant
(the class runs on the async test thread).
- KpiHistoryRecorderActorTests (:1043-1049): two skip-path FoldCount==0
absence checks converted.
Each helper is a private per-file copy, matching the Medium-wave T17
precedent (SiteAlarmAggregatorActorTests.AssertHoldsFor) rather than a shared
TestSupport utility. Proof of the mechanism: a standalone (non-repo) harness
run 100 trials of a real background thread flipping a boolean true then back
to false inside a 300ms window — Thread.Sleep(300)+one sample missed the
violation 100/100 times (false pass), continuous 20ms polling caught it
100/100 times. Most of the actual conversions here guard monotonic counters
(their single-sample variant would eventually see the final value too), so
each converted test carries an inline honesty note on what specifically the
conversion buys for that assertion (fail-fast vs. true flip-back detection).
P8-9: ScadaBridgeTelemetryTests.EmitHelpers_DoNotThrow called
SetQueueDepthProvider(() => 5) against the process-global row-32 provider
slot with no clear and no [Collection] — a landmine for any future
same-process reader of scadabridge.store_and_forward.queue.depth. Fixed with
compare-and-clear in a finally via the existing (production, untouched)
ClearQueueDepthProvider. Searched this assembly and the whole test tree for a
second same-process reader that asserts on the value: none exists today
(MetricsEndpointTests scrapes /metrics but only asserts on the response
shape, and the only value-asserting test, QueueDepthGaugeTests, lives in
StoreAndForward.Tests — a separate test-host process the leak cannot reach),
so no [Collection] was added; the test's doc comment records the search and
flags it for re-check if that changes.
Test-only change, zero production edits. Full suites green: DCL.Tests
342/342, Communication.Tests 729/729, StoreAndForward.Tests 135/135,
KpiHistory.Tests 54/54, Host.Tests 522/522. Each converted test additionally
looped 20x in isolation with zero flakes.
scadabridge_site_connection_up never counted data connections. It counts open
central->site gRPC subscriber streams (Debug View + the site-wide alarm feed),
so it correctly reads 0 on a healthy site nobody is watching — and the name
invited reading it as device health. That misreading has already cost a live
debugging session: register row 48's 'connection_up is 0 on all six site
nodes' was healthy steady state, not the fault it was diagnosed as.
Two halves, per the row:
RENAME. scadabridge.site.connection.up -> scadabridge.site.stream.subscribers.active
(helpers SiteConnectionOpened/Closed -> SiteStreamSubscriberOpened/Closed), and
the instrument gains the unit:"1" the other gauges already carried. Every
reference updated: the gRPC server, both test suites, Component-Communication.md,
components/Commons.md, docker/README.md and docker/seed-live-probe.sh. A test
now pins the new name AND asserts the old one is gone, so it cannot creep back.
NEW. scadabridge.site.data_connections.connected / .total — the first exported
data-connection signal (the state existed on the health report and in the CLI,
but never as a metric). connected < total is the alert condition; neither
number alone separates 'a device is down' from 'nothing is configured', which
is why the denominator ships with the numerator.
Sourcing is deliberate on two counts. It is fed by the DCL at its four state
transitions rather than derived from the health report, so the metric survives
a dead report pipeline — the exact failure the 'metrics stale' flag exists to
catch, and a derived gauge would go blind at the same moment. And it uses a
static registry reached through ScadaBridgeTelemetry (the SiteConnectionOpened
precedent) rather than a DI-injected holder: the DCL actors already take
ISiteHealthCollector through their constructors, and threading a second
dependency through both would ripple into every test that builds them. It also
keeps SiteHealthCollector untouched, which matters right now — another agent is
concurrently editing that file for the tag-resolution path.
Removal is wired too: an undeployed connection leaves the registry, so it stops
counting toward the total instead of latching connected < total on forever.
Both gauges read 0 on the standby (connections open on the active node only) —
healthy, documented, and called out in the docs so it does not become the next
site_connection_up.
No ObservedMeters allowlist change: all three instruments ride the existing
ZB.MOM.WW.ScadaBridge meter. (An unlisted meter exports nothing, silently.)
Tests: Commons 711 passed (9 new, delta-based against a baseline with unique
per-test connection names, so they do not inherit the register row 32
QueueDepthGaugeTests static-state flake); Communication 717; DCL 319.
Extend CommunicationOptionsValidator with eager bounds for the four T4
live-alarm-cache options (linger >= 0, reconcile > 0, seed concurrency 1..64,
subscribers-per-site >= 1). Enforce the per-site viewer cap fail-safe in
SiteAlarmLiveCacheService.Subscribe (reject excess viewers with a no-op
disposable rather than growing the list or throwing into the Blazor render
path). Surface two telemetry instruments on the existing ScadaBridgeTelemetry
meter: an active-aggregator observable gauge and a reconnect counter, wired from
the aggregator actor's PreStart/PostStop and its NodeA<->NodeB flip /
reconcile-driven reopen.
Claude-Session: https://claude.ai/code/session_01MtdgwpEeCUn6cUA5f1LMPj