Every emit site hands FlowTraceCollector the same AuditEvent it hands the
writer, but redaction and payload capping lived inside the writers, which
return a NEW filtered record — so the inline copy that rides
ScriptCallResult.TraceEvents / RouteToCallResponse.TraceEvents was the RAW
event: no per-target SQL-parameter redaction, no header scrubbing, no 8 KB /
64 KB truncation. Live and Replay of the same execution could therefore show
different payloads, and the 500-event-only cap left the reply free to breach
the 4 MB gRPC receive limit — which would fail a real call, since the same
reply carries the script's return value.
The collector now applies the host IAuditRedactor itself (outside the lock;
the writers keep their own idempotent Apply) and enforces a byte budget
(DefaultMaxBytes = 1 MB over the redacted DetailsJson) alongside the event
cap, flagging Truncated when either trips. It moves to Commons
(Types/Debugging) so the central FlowDebugRunner can share it.
The redactor is a singleton, so ScriptRunLauncher resolves it from the ROOT
provider and keeps constructing the collector before the try — the traced
ScriptRun row is emitted from the catch blocks too, including the
shed-at-dequeue path that throws before the DI scope exists.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
Review of Task 3: the sink invoke sat before WriteAsync/ForwardAsync inside the
best-effort try, so a throwing sink would have silently dropped the durable
row. GuardTraceSink wraps the delegate in every helper ctor (and Collect
guards EmitTrace); pinned by a throwing-sink test. ScriptRunLauncher no longer
allocates a collector for a traced run with no reply target (Nobody) — the
list would never be read. FlowTraceCollector.Complete pinned at unit level;
Snapshot documented as a non-closing peek.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
ScriptRuntimeContext caches a trace sink (null on an untraced run, so the
production path is byte-identical) and threads it into the ExternalSystem /
Database / Notify helpers and AuditingDbConnection→AuditingDbCommand (onAudit).
All eight outbound emit sites hand the SAME AuditEvent instance to the sink
first, then to the writer/forwarder. FlowTraceCollector gains Completed +
Complete(): ScriptRunLauncher closes the collector where it builds the reply
snapshot, so un-awaited calls finishing after the run returned never mutate a
list the reply was built from. Cap (500) unchanged. Plan 2026-09-06 D5.
Claude-Session: https://claude.ai/code/session_01NcMG6xXdsJbmD2wYAgkK29
Flow Debugger (design 2026-09-05 §5.1/§5.2): the context is the single funnel for
SetAttribute / WriteBatchAndWait / WaitInternal, so it emits the write/wait rows (collector
first, then the best-effort IAuditWriter whose redactor applies the payload cap), stamps
Trace on SetStaticAttributeCommand and ScriptCallRequest, and hands the flag + sink to the
inline CallShared child context. Untraced contexts emit nothing (pinned).
Claude-Session: https://claude.ai/code/session_01GSLkkHKz9JrAtmJjmQK3cP