Joseph Doherty 7c14a69091 feat(#23): elevate connection-binding completeness to a deploy-gating Error (M2.8)
Pre-deployment validation only WARNED when a data-sourced attribute had no
connection binding, so an instance with unresolved bindings still passed IsValid
and could deploy. There was also no check that a binding resolves to a connection
that actually exists at the target site.

- ValidationService.Validate gains an opt-in `enforceConnectionBindings` flag
  (default false) plus a `siteConnectionNames` set. Default-false keeps the
  template DESIGN-TIME path (ManagementActor.HandleValidateTemplate) non-blocking,
  since bindings are legitimately set later at instance/deploy time. The DEPLOY
  path (FlatteningPipeline) opts in (true) so:
    * a data-sourced attribute with no binding is now a deploy-gating Error;
    * a binding to a connection that does not exist on the target site is an Error.
  Static (non-data-sourced) attributes are never flagged.
- FlatteningPipeline computes the site-connection-names set from the loaded site
  data connections (mirroring M2.1's alarmCapableConnectionNames) and threads it in.
- Tests: TemplateEngine.Tests covers design-time warning / deploy-time error /
  static-ok / exists-at-site / non-existent-connection. New
  FlatteningPipelineConnectionBindingTests proves the deploy path enforces it.

Mark M2.7 + M2.8 completed in the plan task tracker.
2026-06-16 05:28:06 -04:00
Joseph Doherty 41d828e38e fix(deploy): address M2.1 review nits — comparer consistency + comments (#22)
- connection-name capable-set comparer kept as StringComparer.Ordinal:
  FlatteningService and SemanticValidator use all-ordinal name-keyed
  dictionaries throughout; OrdinalIgnoreCase would be inconsistent with
  the rest of the binding-resolution path — added comment documenting this
- IsAlarmCapable protocol-match confirmed consistent with DataConnectionFactory
  (both OrdinalIgnoreCase); added case-insensitive InlineData variants
  (OPCUA, opcua, mxgateway, MXGATEWAY) to lock the contract
- clarified FlatteningPipeline comment: "filters connections by alarm-capable
  protocol, then collects their names" (was "maps from the protocol string")
- added DataConnectionLayer/DataConnectionFactory.cs path reference to
  AlarmCapableProtocols sync-risk comment
2026-06-15 13:27:26 -04:00
Joseph Doherty d6909207a8 fix(deploy): wire native-alarm-source capability validation into flattening pipeline (#22)
FlatteningPipeline loaded data connections but never passed the alarm-capable
connection set to SemanticValidator, so the native-alarm-source capability check
(built but inert) never ran — a source bound to a non-alarm-capable connection
deployed silently. Compute the capable set (IAlarmSubscribableConnection: OPC UA
+ MxGateway) and thread it through ValidationService to SemanticValidator.
2026-06-15 13:20:20 -04:00
Joseph Doherty 877f2e200b feat(scadabridge): emit scadabridge.deployments.applied on deployment success 2026-06-01 16:52:09 -04:00
Joseph Doherty 7b0b9c7365 refactor: rename ScadaLink → ZB.MOM.WW.ScadaBridge (code + projects + namespaces)
Solution + 23 src projects + 26 test projects renamed; folders, csproj,
namespaces, and ScadaLinkDbContext/ScadaBridgeDbContext class updated.
ActorSystem "scadalink" → "scadabridge", Akka seed-node URLs migrated.
SQL roles/logins, LDAP domains, CLI command name, and CLI config dir
(~/.scadalink → ~/.scadabridge) also renamed.

Build green; 5 Host.Tests fail awaiting SQL login rename in next commit.
Pre-existing StaleTagMonitor timing flakes unchanged.

Rename script committed at tools/rename-to-scadabridge.sh.
2026-05-28 09:37:45 -04:00