vq04 (active central) killed with SCM auto-restart disabled and held down 94 s:
UNREACHABLE +11.4 s, [leader-auto-down] DOWNING +26.4 s, survivor vq03 active
+26.7 s. Recovery config restored byte-identical before Start-Service; vq04 rejoined
as standby in ~4.7 s with no exit-75. Also corrects the earlier Drill A 'sampler gap'
(an awk keying error; vq04 was ready at +20.8 s).
Claude-Session: https://claude.ai/code/session_01GT67AFKC45MBz1wPZnVbX8
Both centrals killed in turn (Stop-Process on the service PID). SCM restart in ~5 s;
the survivor downed the old incarnation at ~+9-10 s and took the active role; the
victim rejoined as standby at ~+21 s. leader-auto-down stood aside (already Down),
so its 15 s timer path was not exercised on QA. Site-pair drill still pending
(Z28061 slot, #142).
Claude-Session: https://claude.ai/code/session_01GT67AFKC45MBz1wPZnVbX8