Joseph Doherty 2a7dee4afa feat(centralui+dcl): Test Bindings popup — one-shot live read of bound tags
Adds a Test Bindings button to the Connection Bindings table on the Configure
Instance page that opens a modal showing the live current value of every bound
attribute. Reuses the routing path that the OPC UA tag browser landed on:

  Central:  TestBindingsDialog → IBindingTester → CommunicationService
            → ReadTagValuesCommand → SiteEnvelope (Ask)
  Site:     SiteCommunicationActor → DeploymentManagerActor singleton
            → DataConnectionManagerActor → child DataConnectionActor
            → _adapter.ReadBatchAsync

Split mirrors the browse handler:
  • Manager owns ConnectionNotFound (only it sees the per-site connection set).
  • Child owns ConnectionNotConnected (pre-call status check, never stash —
    read is interactive design-time), Timeout (OperationCanceledException),
    ServerError (any other exception). Per-tag failures from ReadBatchAsync
    become failure TagReadOutcomes without aborting the batch.

CentralUI:
  • IBindingTester / BindingTester — Design-role guard via HasClaim against
    JwtTokenService.RoleClaimType (not IsInRole — see c1e16cf), typed
    transport-failure translation.
  • TestBindingsDialog — ShowAsync(siteId, rows, instanceLabel) method-arg
    pattern (no Razor parameter race; see 2c138b6), groups rows by connection
    and issues one ReadAsync per connection in parallel, per-row error subline
    + per-connection banner, Refresh button re-issues the reads.
  • InstanceConfigure.razor — Test Bindings button next to Save Bindings,
    disabled when no testable rows. OPC UA only today (other protocols have
    no ReadTagValuesCommand wiring yet).

Tests:
  • Commons: ReadTagValuesCommand discovered by ManagementCommandRegistry.
  • DataConnectionLayer: unknown connection → ConnectionNotFound,
    not-connected adapter → ConnectionNotConnected (ReadBatchAsync NOT called),
    success-path mapping (Good/Bad + per-tag error), cancellation → Timeout.
  • CentralUI: register IBindingTester (and the previously-missing
    IOpcUaBrowseService) on the existing InstanceConfigureAuditDrillinTests
    Bunit container so the page renders cleanly with the new dialog.
2026-05-28 13:25:48 -04:00
Joseph Doherty d285174597 feat(dcl+ui): rename BrowseOpcUaNode -> ConnectionName-keyed; implement site handler + dialog failure mapping
- BrowseOpcUaNodeCommand: int DataConnectionId -> string ConnectionName
  (site DataConnectionManagerActor indexes children by name; CentralUI
  already has the connection name in scope via the dropdown — no extra
  plumbing across the trust boundary).
- IOpcUaBrowseService / OpcUaBrowseService: parameter renamed accordingly.
- OpcUaBrowserDialog: collapse the duplicate ConnectionName parameters
  (display label and routing key are the same string).
- Task 10: DataConnectionManagerActor forwards BrowseOpcUaNodeCommand to
  its child by name (owns ConnectionNotFound); DataConnectionActor adds
  the receive across all three lifecycle states (Connecting / Connected
  / Reconnecting) and maps adapter outcomes to BrowseFailureKind
  (NotBrowsable / ConnectionNotConnected / Timeout / ServerError).
- Task 17: SetFailure in OpcUaBrowserDialog implements the full
  BrowseFailureKind switch with friendly UI messages.
- Tests: DataConnectionManagerBrowseHandlerTests covers ConnectionNotFound,
  NotBrowsable, success, and ConnectionNotConnectedException paths.
2026-05-28 12:09:43 -04:00