Joseph Doherty 2807b5a3ea fix(transport)+test: close deferred-work register rows 58, 60, 65 (Low-tail sweep)
Row 65 — trigger FIRED, fixed. BundleUnlockAttempt rows were pruned only by
nodes actively serving unlocks, so a cluster that stopped importing entirely
left its last rows in place forever. The row's own trigger was "Transport gains
a central scheduler a prune tick could ride" — it has one now:
BundleSessionEvictionService, the central-only 1-minute session sweep added by
the transport-session fixes. It now also ticks the new
IBundleUnlockAttemptWindow.PruneAsync. Both drivers share the ONE 15-minute CAS
cadence claim, so ticking on a 1-minute sweep costs at most one bounded DELETE
per quarter hour and the two can never prune concurrently. PruneAsync is
contractually non-throwing (unlike TryRegisterAttemptAsync, which throws and
lets the limiter own the fail-open decision) — a background sweep has no caller
to report to and must survive a database blip. Both Transport docs updated;
three tests in FleetWideUnlockThrottleTests, incl. the retention sweep running
with no unlock traffic anywhere in the test, which is the whole point.

Row 58 — closed with a pin, and the OLD pin was found blind. The existing
Deployments_Dispose_UnsubscribesFromNotifier is behavioural: it is satisfied by
the _disposed guard alone, so deleting the `-=` from Dispose leaves it green
while the singleton notifier keeps a delegate pinning the circuit-scoped
component. Verified by mutation — with the `-=` removed the old test still
passed and only the two new pins failed. Added:
  * a structural retention pin asserting the notifier's invocation list actually
    shrinks to 0 on Dispose;
  * a source scan pinning the row's stated TRIGGER ("a second page subscribes,
    or any subscriber lands without a matching Dispose unsubscribe") — every
    CentralUI file that subscribes must also unsubscribe and be IDisposable,
    with a non-empty guard so the scan cannot pass vacuously.

Row 60 — closed with a pin, and the register's premise corrected.
GlobalArtifactSnapshot does NOT hold EF-materialised entities: it is projected
into pure Commons DTOs before the fan-out. The EF state that genuinely crosses
into the parallel send is the tracked Site entities the lambda closes over, and
that is safe only while lazy loading is off. Pinned in ConfigurationDatabase
.Tests two ways — no proxies extension on the built DbContextOptions, and no
EntityFrameworkCore.Proxies package reference anywhere in the repo (the
structurally stronger half: UseLazyLoadingProxies() is not a compilable call
without it). The real invariant is now spelled out at the fan-out itself.

Row 59 — no product change; added the missing tripwire remark stating the
constraint the safety argument rests on (serial by design, one scoped DbContext,
do not Task.WhenAll; if it gets slow the fix is a scope PER SITE, not a shared
scope under fan-out). Line numbers in the register have drifted to :528-545.

Rows 36, 37, 64: verification only, no change — see the sweep report.
2026-08-17 03:42:31 -04:00
Joseph Doherty 98c9458830 test(transport): row 74 — gauge asserts become delta-over-scoped-action, not absolute
BundleSessionObservabilityTests' two gauge facts asserted absolute values
(Assert.Equal(0, baseline), Assert.Equal(2, ReadGauge())) against what is a
single process-global provider slot — the same latent shape as the row-32
QueueDepthGaugeTests flake, correct only while this file is the slot's sole
registrant. Converted to the delta-over-scoped-action pattern the row-66
rejection-counter facts in the same file already use: a new ReadGaugeDelta
helper measures how far the instrument MOVED across an action driven by this
test's own store, so an inherited non-zero baseline cancels out.

Two assertions got stronger in the process. The post-clear check was
Assert.Equal(0, ReadGauge()) — "the instrument reports zero", which any
unregistered slot satisfies; it is now "opening more sessions on the detached
store moves the gauge by nothing", which is the actual claim. And the
compare-and-clear fact gained a negative control: the superseded store's opens
must NOT reach the instrument, so a slot still pointing at oldStore can no
longer satisfy the assertion by coincidence when both stores hold equal counts.

Fail-before (temporary probe, not committed): with a foreign provider returning
7 registered before the service starts, the OLD body fails
`Assert.Equal(0, baseline)` with `Expected: 0 / Actual: 7`; the NEW delta body
passes the identical scenario.

Honest residual documented on the helper: a gauge has one slot and
last-writer-wins, so a registrant that clobbers it BETWEEN the two reads is
unrecoverable read-side — that needs row-32's mutual exclusion. It cannot arise
today (this is the only file in the assembly constructing a
BundleSessionEvictionService, and test assemblies are separate processes); a
second such file should bring the collection treatment with it.

Transport.Tests: 180/180 green.
2026-08-15 21:16:55 -04:00
Joseph Doherty 90ce099928 feat(transport): counter for import-session cap rejections (register row 66)
Row 53 shipped the scadabridge.central.transport.import_sessions.open gauge
and a Warning log on a cap hit, but a log line is not something an operator
can alert on. Adds the companion counter

    scadabridge.central.transport.import_sessions.rejected

on the existing ZB.MOM.WW.ScadaBridge meter, so no ObservedMeters allowlist
change is needed (an unlisted meter exports nothing, silently).

The emit point is deliberately narrow. BundleSessionStore.Open tests the cap
TWICE — once on entry and again after EvictExpired() — and only the second
test is a rejection: a store full of merely expired sessions reclaims a slot
and admits the caller. Counting the first would make the series fire
routinely on any node whose sweep had not yet run, turning a page-worthy
signal into background noise. Re-Opening an already-open session id skips
the cap block entirely and is likewise not counted.

The two instruments are diagnostic as a pair: rejections rising while the
gauge oscillates below the cap is genuine concurrency (raise the cap);
rejections rising while the gauge sits pinned at the cap is a session leak
(register row 43's signature), where raising the cap only defers the problem.

Tests assert a delta over a scoped action rather than an absolute value, so
they do not inherit the register row 32 static-state flake that makes
QueueDepthGaugeTests fail only under the full concurrent suite. Negative
controls cover under-cap, expired-reclaim, and duplicate-session-id.

Tests: 11 passed in BundleSessionObservabilityTests (6 existing + 5 new).
2026-08-15 12:42:56 -04:00
Joseph Doherty 372ea4df1b feat(transport): observability for the import-session cap (register row 53)
Nothing counted open import sessions and nothing logged a rejection at
MaxConcurrentImportSessions (default 8), so the register-row-43 session leak
could only be inferred from rotating test failures.

- Gauge scadabridge.central.transport.import_sessions.open on the existing
  ZB.MOM.WW.ScadaBridge meter — already in SiteServiceRegistration.ObservedMeters
  (the ZbTelemetryOptions.Meters allowlist), so no telemetry config change is
  needed and the series is not silently dropped. Provider-backed, mirroring the
  StoreAndForward queue-depth gauge: registered by BundleSessionEvictionService
  .StartAsync (Transport's only lifecycle seam) and identity-checked-cleared on
  StopAsync so a late stop cannot clobber a newer registrant.
- IBundleSessionStore.OpenSessionCount counts only UNEXPIRED sessions. The raw
  dictionary count would report the node as pinned at the cap for up to a
  one-minute sweep interval after a burst had drained — the exact false positive
  the instrument exists to rule out.
- BundleSessionStore.Open logs Warning with open count, cap and TTL when it
  rejects. Fires only on a real cap hit: a store full of expired sessions is
  reclaimed first and logs nothing.
- Docs: docs/components/Transport.md + docs/requirements/Component-Transport.md.

Tests: Transport 173 passed (+6 new — Warning content, two negative controls,
unexpired-only counting, gauge register/clear, no-clobber-on-late-stop).
2026-08-15 11:42:31 -04:00