Joseph Doherty 11eb5157e6 fix(dcl): dispose+detach previous OPC UA client on reconnect (S1) — stops session leak and stale ConnectionLost flapping 2026-07-08 23:16:27 -04:00
Joseph Doherty 9cff87fe85 docs(comments): strip internal task/milestone/bundle bookkeeping from code comments
Remove project bookkeeping citations from shipped code comments across the
solution: hyphenated task IDs (WP-14, StoreAndForward-025), milestone/task/
issue refs (M3, Task 4, Audit Log #23, #21), Bundle X task-bundle labels,
and C/D/K/S/T phase labels.

Comment text only — no code logic, string/log literals, or XML-doc structure
changed. Genuine descriptions are preserved (only the citation is stripped),
and technical lookalikes are retained (UTF-8, SHA-256, T00:00:00, M365,
UTC-5, pre-C4/pre-C5 schema versions). Flagged by the new CommentChecker
TaskReferenceInComment / TrackingReferenceInComment checks plus targeted
grep passes; full solution builds clean, append-only guard tests pass.
2026-07-07 11:03:26 -04:00
Joseph Doherty ce4d5f0639 feat(dcl): surface MxGateway attribute DataType through browse seam 2026-06-27 13:24:25 -04:00
Joseph Doherty fd618cf1dc fix(review): full code-review remediation — 5 High + Medium/Low across 16 modules
Remediation from the full per-module code review at 4307c381 (findings recorded
separately in code-reviews/).

Highs fixed:
- DeploymentManager-025/SiteRuntime-031: stop broadcasting notification lists + SMTP
  configs (incl. credentials) to sites; site purges already-persisted rows on apply
  (enforces the central-only delivery design; clears plaintext SMTP creds at rest).
- DataConnectionLayer-023: guard the native-alarm subscribe path against the
  mid-flight-unsubscribe adapter-feed leak (mirrors the DCL-021 tag-path fix).
- SiteEventLogging-024: normalize From/To query bounds to UTC (the -016 fix the
  audit trail claimed but never committed).
- KpiHistory-001: add an in-flight guard to the recorder sample tick.
- ScriptAnalysis-001: harden the trust analyzer's TPA-absent fallback (resolve
  forbidden anchors in the minimal reference set; warn on degraded mode) — anchors
  added to validation references only, never the compile gate.
(InboundAPI-026 left to the feat/ipsen-movein effort per owner decision.)

Medium/Low: DM-026 deterministic deploy-status tiebreaker; SR-027/028/029/030
native-alarm leak/phantom-active/delete-during-redeploy fixes; AL-013/014/016;
TE-024 (folder-mutation audit rows now persisted)/025; SF-025 gauge-provider
clear-on-stop; ESG-025/026; SEC-023/024/025; SCA-007/008/009; plus doc/test
accuracy COM-023/024, HOST-025/026, HM-024/025, NS-027/028.

Full-solution build 0 warnings; ~3560 tests across 18 touched suites green.
2026-06-20 17:55:12 -04:00
Joseph Doherty 733c7bf66c feat(dcl): OPC UA verify-endpoint probe with untrusted-cert capture (T17) 2026-06-18 03:00:55 -04:00
Joseph Doherty c00c8241b3 feat(dcl): bounded recursive OPC UA address-space search adapter (T15) 2026-06-18 02:45:01 -04:00
Joseph Doherty 2cfe0de927 feat(dcl): BrowseNext continuation paging + StubOpcUaClient canned browse (T15) 2026-06-18 02:21:59 -04:00
Joseph Doherty 5fd77c7155 feat(dcl): surface OPC UA DataType/ValueRank/Writable on BrowseNode (T16 type-info) 2026-06-18 02:02:23 -04:00
Joseph Doherty eeb6210151 fix(dcl): address MXAccess array attributes with trailing "[]" on write
MXAccess silently no-ops a whole-array write unless the item reference
ends in "[]" (e.g. "<object>.MoveInWorkOrderNumbers[]") — the COM Write
returns success but the value never commits. Reads work either way, so
the bug surfaced only on writes. Mirror the AVEVA MES Camstar API, which
registers array tags as "<object>.<attr>[]" (scalars have no brackets).

WriteAsync now resolves/advises/writes array values against tag + "[]"
(scalars unchanged), keeping the original tag for result mapping. Adds
IsArrayValue matching the ToMxValue/PadArrayToDeclaredSizeAsync array set.

Verified live via mxwrtest against the deployed gateway: bare ref write
ok but read-back unchanged; "[]" ref write commits (read-back changes,
fresh source timestamp). No RealMxGatewayClient unit harness exists (the
gRPC session is concrete) — consistent with how the sibling supervisory/
pad/encode fixes are verified.
2026-06-17 08:32:03 -04:00
Joseph Doherty 45b23476fc fix(dcl): pad List writes to the Galaxy array's full declared size
Even with correct array encoding (30d07b9), Ipsen MoveIn array writes still
hung: the Galaxy MES-receiver arrays are fixed-size SAFEARRAYs (e.g.
MoveInWorkOrderNumbers = SAFEARRAY(VT_BSTR) dimensions:[50]) and MXAccess only
accepts a write that supplies ALL slots. ScadaBridge sent just the N elements
the MES provided (1-2), so the COM write blocked. Verified on the live gateway:
a full-size (50) constructed array writes via WriteBulk in ~34ms; a short one
does not.

RealMxGatewayClient.WriteAsync now, for a list value, reads the tag's current
array to learn its slot count and pads the value to that length with
element-type defaults (empty string / 0 / false / default) — the caller's
values fill slots 0..N-1, the rest are cleared. The PLC reads the valid count
from a separate scalar (MoveInNumberWorkOrders). If the size can't be
determined (read fails / not an array) the value is written unpadded and a
warning is logged. Scalars are unaffected.
2026-06-17 06:34:05 -04:00
Joseph Doherty 30d07b91f4 fix(dcl): write List attributes as real MXAccess arrays (not a stringified List)
The Ipsen MoveIn e2e (after the supervisory-advise fix landed scalar writes)
exposed a second blocker: writes to List-typed attributes
(MoveInWorkOrderNumbers / MoveInPartNumbers, List<string>) hung at the 30s
device-write timeout while scalar writes succeeded.

InstanceActor.HandleSetDataAttribute already decodes a List attribute's
canonical JSON into a typed List<T> before the write (so the DCL can push a
real array), but RealMxGatewayClient.ToMxValue only had scalar cases — a
List<T> fell through to Convert.ToString and wrote the garbage string
"System.Collections.Generic.List`1[System.String]" to the array Galaxy
node, which the gateway's COM write rejected/blocked.

Add IReadOnlyList<bool|int|long|float|double|string|DateTimeOffset|DateTime>
cases that call the client package's typed array encoders
(VT_ARRAY|VT_BSTR etc.); List<DateTime> is mapped to DateTimeOffset. Covers
every element type AttributeValueCodec produces.
2026-06-17 06:07:40 -04:00
Joseph Doherty b5333d0f15 fix(dcl): default MxGateway advises to supervisory when WriteUserId==0
Writes through the MxGateway data connection (e.g. the Ipsen MoveIn flow
writing MES-receiver attributes) hung ~30s and changed nothing, while reads
of the same attributes worked. Root cause: MXAccess only accepts a write on
an item that holds a SUPERVISORY advise; the write path did AddItem +
WriteBulk with no advise and the monitoring subscription used a plain Advise,
so the worker's synchronous COM Write blocked until the gateway command
timeout. (Plain, non-secured writes need no user/login.) Verified live: with a
supervisory advise the write returns ok in ~22ms; without it it does not.

When the connection has no MXAccess write-user context (WriteUserId == 0) it
now behaves as a supervisory client: every advise defaults to
AdviseSupervisory — both the monitoring subscription (SubscribeAsync) and the
write path — so one connection can read and write. A supervisory advise still
delivers OnDataChange (the worker treats either advice kind as sufficient for
updates) so monitoring is unaffected, and the worker's UnAdvise tears down
either kind, so unsubscribe is unchanged. AdviseSupervisory is issued as a raw
MxCommandKind.AdviseSupervisory via the session's Invoke (the client package
exposes only plain Advise). The advise runs at most once per handle via a
Lazy<Task> so a concurrent first-time subscribe+write on the same new handle
both await the same advise (neither writes before it completes); a faulted
advise is evicted so the next write retries. Dropped on unsubscribe. A
configured non-zero WriteUserId keeps the prior plain-advise behaviour.
2026-06-17 05:52:30 -04:00
Joseph Doherty 9b78e6071d fix(dcl): identify MxGateway native alarms by object-relative reference
Surface native (Galaxy/MxGateway) alarms by their object-relative reference
(e.g. "Z28061.HeartbeatTimeoutAlarm") instead of the gateway's full provider
reference ("Galaxy!<area>.<object>.<alarm>"). The area is already preserved in
Category and the object reference is globally unique within the galaxy, so the
full provider prefix added only noise to the alarm identity operators see.

MxGatewayAlarmMapper.MapTransition/MapSnapshot now set SourceReference from
SourceObjectReference, falling back to AlarmFullReference only when the gateway
omits the object reference. +2 mapper tests; full DCL suite green (158).
2026-06-16 19:46:44 -04:00
Joseph Doherty 3945789970 docs(dcl): M2.13 review nits — OriginalRaiseTime ConditionRefresh/UTC caveats + Description-vs-Message note (#27) 2026-06-16 06:40:40 -04:00
Joseph Doherty 722b8663c1 feat(dcl): populate obtainable NativeAlarmTransition fields from OPC UA and MxGateway (#27, M2.13)
OPC UA (RealOpcUaClient):
- Append 5 new SelectClauses at indices 13–17 (never renumber 0–12):
  - 13: AlarmConditionType/ActiveState/TransitionTime → OriginalRaiseTime
  - 14–17: LimitAlarmType HighHighLimit/HighLimit/LowLimit/LowLowLimit → LimitValue
- New OpcUaAlarmMapper.PickLimitValue helper: first non-null in HiHi→Hi→Lo→LoLo
  priority order, InvariantCulture-formatted; empty string for non-limit alarm types.
- HandleAlarmEvent reads new indices with fields.Count > N guards; hard minimum (6)
  unchanged so base ConditionType events still process without the limit fields.
- Document unavailable-by-protocol fields (Category, Description, OperatorUser,
  CurrentValue) inline in BuildAlarmEventFilter and HandleAlarmEvent.

MxGateway (MxGatewayAlarmMapper):
- MapTransition: CurrentValue and LimitValue now populated via MxValueToString
  (uses MxValueExtensions.ToClrValue + InvariantCulture) from OnAlarmTransitionEvent
  proto fields current_value/limit_value.
- MapSnapshot: same — populated from ActiveAlarmSnapshot.current_value/limit_value.
- MxValueToString helper (internal): null-safe MxValue → string conversion.

Tests (17 new, 40 total pass):
- OpcUaAlarmMapperTests: PickLimitValue priority, InvariantCulture, all-null case.
- MxGatewayAlarmMapperTests: CurrentValue/LimitValue populate from double/string
  MxValue; absent fields yield empty strings.
- RealOpcUaClientAlarmFilterTests: index alignment assertions (count=18, per-index
  TypeDefinitionId+BrowsePath), regression guard on existing indices 0–12.
2026-06-16 06:37:19 -04:00
Joseph Doherty 00304a26e6 fix(dcl): resolve OPC UA alarm type NodeId to friendly name so conditionFilter works (#8)
HandleAlarmEvent set AlarmTypeName to the event-type NodeId string ("i=9341"),
but the client-side conditionFilter gate (and the OPC UA WhereClause) use friendly
type names — so a friendly-name filter built a correct server WhereClause yet the
client gate dropped every event (zero alarms delivered). Resolve the event-type
NodeId to its friendly name via an inverse of KnownConditionTypeIds (NodeId-string
fallback for custom types) so both sides agree. Also fix a dead-code ternary in
the SourceName derivation.
2026-06-15 14:25:35 -04:00
Joseph Doherty 8825df56be fix(dcl): apply native-alarm conditionFilter (client-side gate + OPC UA WhereClause) (#8)
conditionFilter was plumbed end-to-end but applied nowhere — a filtered source
silently mirrored all conditions. Define the filter as a comma-separated,
case-insensitive list of condition type names (blank = all); enforce it
authoritatively client-side in DataConnectionActor routing (uniform across OPC UA
+ MxGateway) and, for OPC UA, additionally build a server-side EventFilter
WhereClause as a bandwidth optimization.
2026-06-15 14:16:10 -04:00
Joseph Doherty eabf270d71 docs: complete XML doc coverage (returns, summaries, inheritdoc)
Resolve all 622 issues flagged by the enhanced CommentChecker: add missing
<returns> tags (incl. the standard phrasing on non-generic Task methods),
add missing <summary> tags, and replace misused/redundant <inheritdoc/> on
members that override or implement nothing with real documentation.
Documentation-only — no behavior change; solution builds clean.
2026-06-03 11:39:32 -04:00
Joseph Doherty c7411700dc feat(dcl): MxGateway StreamAlarms adapter (snapshot + live transitions, reconnecting)
Adds IAlarmSubscribableConnection to MxGatewayDataConnection (shared session-less
feed, ref-counted), IMxGatewayClient.RunAlarmStreamAsync over the package
StreamAlarmsAsync with internal reconnect, and MxGatewayAlarmMapper
(AlarmFeedMessage/OnAlarmTransitionEvent -> NativeAlarmTransition). Behavior
verified against a live gateway in Task 28; mapper unit-tested.
2026-05-29 16:49:25 -04:00
Joseph Doherty 0d30b7dec0 feat(dcl): OPC UA Alarms & Conditions adapter (event subscription + ConditionRefresh)
Adds IAlarmSubscribableConnection to OpcUaDataConnection, IOpcUaClient alarm
subscription methods, and RealOpcUaClient A&C event monitored-item +
EventFilter + ConditionRefresh snapshot, mapping fields via OpcUaAlarmMapper.
Behavior verified against a live A&C server in Task 28; mapper unit-tested.
2026-05-29 16:42:27 -04:00
Joseph Doherty 1fbb814daa feat(dcl): OPC UA A&C field mapper (Task 11 part 1 — pure, unit-tested) 2026-05-29 16:13:02 -04:00
Joseph Doherty 4b6ff49822 fix(dcl+centralui): MxGateway tag browse — lazy attributes, frame-size cap, wider scrollable picker
Expanding a Galaxy object in the tag picker hung on "loading…": the browse
reply inlined every child's full attribute set (~152 KB), exceeding Akka's
128 KB remote frame, and remoting silently discarded the oversized reply.

Browse path (DataConnectionLayer):
- RealMxGatewayClient: navigation now uses BrowseChildren(include_attributes=
  false) — child objects only — and an object's own attributes load lazily via
  DiscoverHierarchy(root, max_depth=0) when it's expanded. Payload drops from
  ~152 KB/level to a few KB. Seam contract unchanged.
- DataConnectionActor.CapBrowseChildren: protocol-agnostic byte-budget cap
  (~100 KB) on every BrowseNodeResult before it crosses the site→central
  frame, OR-ing the adapter's own Truncated flag. Byte budget, not a count —
  the only bound that holds regardless of NodeId/attribute-name length.
- RealOpcUaClient: requestedMaxReferencesPerNode 1000 → 500 to narrow the
  window before the byte budget applies.
- Graceful gRPC Unimplemented handling → NotSupportedException →
  BrowseFailureKind.NotBrowsable with an actionable message (older gateway
  builds lacking BrowseChildren).

Picker UI (CentralUI):
- NodeBrowserDialog: modal-lg → modal-xl; new scoped .razor.css caps the tree
  at 55vh with its own scrollbar so manual entry + Select/Cancel stay visible.
- Protocol-agnostic failure messages (was hardcoded "OPC UA …"); renamed the
  leftover opcua-browser-tree class to node-browser-tree.

Tests: new frame-budget cap test + NotSupported=>NotBrowsable mapping test;
DCL suite 88/88. Doc: Component-DataConnectionLayer.md records the lazy
attribute-light browse and the frame-size guard.
2026-05-29 09:53:19 -04:00
Joseph Doherty 20c24ef260 feat(dcl): RealMxGatewayClient over ZB.MOM.WW.MxGateway.Client
Seam implementation wrapping the gateway client + GalaxyRepositoryClient:
OpenSession/Register, AddItem+Advise subscribe, ReadBulk/WriteBulk with handle
tracking, StreamEvents loop with worker_sequence resume + OPC-style quality
mapping, and Galaxy BrowseChildren mapping (objects keyed by gobject id,
attributes by full tag reference). Only type touching the generated contracts.
2026-05-29 07:55:32 -04:00
Joseph Doherty 0a693e0be9 feat(dcl): MxGatewayDataConnection adapter (connect/subscribe/read/write/wait/browse)
Implements IDataConnection + IBrowsableDataConnection over the IMxGatewayClient
seam: connect/disconnect with once-only Disconnected guard + background event
loop, subscribe/unsubscribe with tag routing, read/write batch with per-tag
error classification, WriteBatchAndWait, and Galaxy browse mapping. Covers plan
Tasks 6-10. Full unit coverage via FakeMxGatewayClient (12 tests).
2026-05-29 07:50:16 -04:00
Joseph Doherty fe02ec5664 feat(dcl): MxGateway client seam interfaces + global options 2026-05-29 07:44:07 -04:00
Joseph Doherty 6999aedc60 feat(dcl): implement BrowseChildrenAsync on RealOpcUaClient 2026-05-28 11:59:03 -04:00
Joseph Doherty 0b4b4c02f6 feat(dcl): implement IBrowsableDataConnection on OpcUaDataConnection 2026-05-28 11:58:08 -04:00
Joseph Doherty 7fc1f752f8 feat(dcl): add BrowseChildrenAsync to IOpcUaClient (NotImplementedException stubs) 2026-05-28 11:53:10 -04:00
Joseph Doherty 7b0b9c7365 refactor: rename ScadaLink → ZB.MOM.WW.ScadaBridge (code + projects + namespaces)
Solution + 23 src projects + 26 test projects renamed; folders, csproj,
namespaces, and ScadaLinkDbContext/ScadaBridgeDbContext class updated.
ActorSystem "scadalink" → "scadabridge", Akka seed-node URLs migrated.
SQL roles/logins, LDAP domains, CLI command name, and CLI config dir
(~/.scadalink → ~/.scadabridge) also renamed.

Build green; 5 Host.Tests fail awaiting SQL login rename in next commit.
Pre-existing StaleTagMonitor timing flakes unchanged.

Rename script committed at tools/rename-to-scadabridge.sh.
2026-05-28 09:37:45 -04:00