Measured the unbounded purge burst and found it can force a full ten-table
snapshot resync, then bounded it. No purge-exemption path was added — the
deletes are still CDC-captured like any other write, which stays ruled out
by design; what changed is how many a single tick performs.
MEASURED (harness: real EventLogPurgeService over a real LocalDb file with
site_events genuinely RegisterReplicated, plus a two-node loopback gRPC
replication pair; docker rig untouched):
393 bytes/row incl. indexes => a 1 GB event log holds ~2,731,947 rows.
Expiring all of them in ONE tick: 285 s, 2,731,947 oplog rows,
284 MB oplog payload, 2.73 M row-version tombstones (7-day retention),
i.e. 2.7x LocalDb's MaxOplogRows default of 1,000,000. Crossing that makes
the 60 s maintenance tick prune the oplog and set needs_snapshot — a FULL
snapshot of all ten replicated tables, bought by a routine retention purge.
The resident backlog is produced-minus-drained, so a healthy peer blunts it:
on loopback the same burst peaked at 391,424 and cleared in 6.0 min. That is
the problem, not the reassurance — the old safety margin was a function of
peer throughput and vanished with the peer down. A bounded tick is safe at
any peer speed.
Drain is not a bottleneck: 7.6k-19.8k tombstones/s (20k / 500k / 2.73M runs).
SHIPPED:
- SiteEventLogOptions.MaxPurgedRowsPerTick (default 250,000; 0 = unlimited
escape hatch, negatives rejected). One SHARED budget across the retention
purge and the cap trim — two independently-capped phases would let a tick
emit twice the intended burst. 4x margin under MaxOplogRows, which is also
shared with every other replicated table's ordinary traffic.
- SiteEventLogOptions.PurgeCatchUpInterval (default 5 min, validated > 0 and
<= PurgeInterval). Without it pacing would make retention converge in 11
DAYS at the daily cadence; with it the worst case converges in ~11 ticks
(~55 min), every burst bounded. 5 min rather than 1 so ticks cannot outrun
the peer's drain and re-accumulate the backlog.
- A ceiling is claimed only when work genuinely remains (bounded EXISTS probe),
so an expired set landing exactly on the budget does not arm a no-op retry.
- Visibility: rate-limited (15 min) Warning naming the ceiling and the
accelerated interval, plus an unthrottled counter
scadabridge.site.event_log.purge_ceiling_hits — its SHAPE distinguishes a
backlog converging from a site whose event rate outruns one paced tick.
- The purge loop is a delay loop rather than a PeriodicTimer, so its cadence
now anchors to the END of the previous purge. Documented.
ROW-33 INTERPLAY VERIFIED: pacing lowers each spike and lengthens total purge
duration, but a full 250k tick drains in ~23 s (~4 min even at 10x a real
link's penalty) against the 15-minute sustained dwell and a 5-minute gap to
the next tick. The UNPACED 2.73M burst had only 2.5x of margin (6.0 min), so
pacing makes the badge assumption robust rather than merely preserving it.
Docs travel together: Component-SiteEventLogging.md, topology-guide.md
("Reading the replication backlog" + the row-33 badge note), CLAUDE.md's
purge-burst sentence, and a dated measurement/decision note under docs/plans/.
Fail-before: the new behavioural tests do not compile against the pre-fix
service (RunPurge was void); with PurgeBudget neutralised to always-unlimited,
6 of the new tests fail and all 19 pre-existing ones pass.
Tests: SiteEventLogging 93/93, Commons 715/715, HealthMonitoring 115/115,
Host 505/505. Solution build clean.
scadabridge_site_connection_up never counted data connections. It counts open
central->site gRPC subscriber streams (Debug View + the site-wide alarm feed),
so it correctly reads 0 on a healthy site nobody is watching — and the name
invited reading it as device health. That misreading has already cost a live
debugging session: register row 48's 'connection_up is 0 on all six site
nodes' was healthy steady state, not the fault it was diagnosed as.
Two halves, per the row:
RENAME. scadabridge.site.connection.up -> scadabridge.site.stream.subscribers.active
(helpers SiteConnectionOpened/Closed -> SiteStreamSubscriberOpened/Closed), and
the instrument gains the unit:"1" the other gauges already carried. Every
reference updated: the gRPC server, both test suites, Component-Communication.md,
components/Commons.md, docker/README.md and docker/seed-live-probe.sh. A test
now pins the new name AND asserts the old one is gone, so it cannot creep back.
NEW. scadabridge.site.data_connections.connected / .total — the first exported
data-connection signal (the state existed on the health report and in the CLI,
but never as a metric). connected < total is the alert condition; neither
number alone separates 'a device is down' from 'nothing is configured', which
is why the denominator ships with the numerator.
Sourcing is deliberate on two counts. It is fed by the DCL at its four state
transitions rather than derived from the health report, so the metric survives
a dead report pipeline — the exact failure the 'metrics stale' flag exists to
catch, and a derived gauge would go blind at the same moment. And it uses a
static registry reached through ScadaBridgeTelemetry (the SiteConnectionOpened
precedent) rather than a DI-injected holder: the DCL actors already take
ISiteHealthCollector through their constructors, and threading a second
dependency through both would ripple into every test that builds them. It also
keeps SiteHealthCollector untouched, which matters right now — another agent is
concurrently editing that file for the tag-resolution path.
Removal is wired too: an undeployed connection leaves the registry, so it stops
counting toward the total instead of latching connected < total on forever.
Both gauges read 0 on the standby (connections open on the active node only) —
healthy, documented, and called out in the docs so it does not become the next
site_connection_up.
No ObservedMeters allowlist change: all three instruments ride the existing
ZB.MOM.WW.ScadaBridge meter. (An unlisted meter exports nothing, silently.)
Tests: Commons 711 passed (9 new, delta-based against a baseline with unique
per-test connection names, so they do not inherit the register row 32
QueueDepthGaugeTests static-state flake); Communication 717; DCL 319.
Row 53 shipped the scadabridge.central.transport.import_sessions.open gauge
and a Warning log on a cap hit, but a log line is not something an operator
can alert on. Adds the companion counter
scadabridge.central.transport.import_sessions.rejected
on the existing ZB.MOM.WW.ScadaBridge meter, so no ObservedMeters allowlist
change is needed (an unlisted meter exports nothing, silently).
The emit point is deliberately narrow. BundleSessionStore.Open tests the cap
TWICE — once on entry and again after EvictExpired() — and only the second
test is a rejection: a store full of merely expired sessions reclaims a slot
and admits the caller. Counting the first would make the series fire
routinely on any node whose sweep had not yet run, turning a page-worthy
signal into background noise. Re-Opening an already-open session id skips
the cap block entirely and is likewise not counted.
The two instruments are diagnostic as a pair: rejections rising while the
gauge oscillates below the cap is genuine concurrency (raise the cap);
rejections rising while the gauge sits pinned at the cap is a session leak
(register row 43's signature), where raising the cap only defers the problem.
Tests assert a delta over a scoped action rather than an absolute value, so
they do not inherit the register row 32 static-state flake that makes
QueueDepthGaugeTests fail only under the full concurrent suite. Negative
controls cover under-cap, expired-reclaim, and duplicate-session-id.
Tests: 11 passed in BundleSessionObservabilityTests (6 existing + 5 new).
Nothing counted open import sessions and nothing logged a rejection at
MaxConcurrentImportSessions (default 8), so the register-row-43 session leak
could only be inferred from rotating test failures.
- Gauge scadabridge.central.transport.import_sessions.open on the existing
ZB.MOM.WW.ScadaBridge meter — already in SiteServiceRegistration.ObservedMeters
(the ZbTelemetryOptions.Meters allowlist), so no telemetry config change is
needed and the series is not silently dropped. Provider-backed, mirroring the
StoreAndForward queue-depth gauge: registered by BundleSessionEvictionService
.StartAsync (Transport's only lifecycle seam) and identity-checked-cleared on
StopAsync so a late stop cannot clobber a newer registrant.
- IBundleSessionStore.OpenSessionCount counts only UNEXPIRED sessions. The raw
dictionary count would report the node as pinned at the cap for up to a
one-minute sweep interval after a burst had drained — the exact false positive
the instrument exists to rule out.
- BundleSessionStore.Open logs Warning with open count, cap and TTL when it
rejects. Fires only on a real cap hit: a store full of expired sessions is
reclaimed first and logs nothing.
- Docs: docs/components/Transport.md + docs/requirements/Component-Transport.md.
Tests: Transport 173 passed (+6 new — Warning content, two negative controls,
unexpired-only counting, gauge register/clear, no-clobber-on-late-stop).
Every AttributeValueChanged/AlarmStateChanged rode its own gRPC message on
SiteStreamService; at target scale that is ~37.5k messages/s/site of pure
framing overhead. Coalesce them, additively, with no new RPC.
Wire (sitestream.proto, regenerated via docker/regen-proto.sh sitestream):
InstanceStreamRequest.batching_supported = 3
SiteStreamRequest.batching_supported = 2
SiteStreamEvent.batch = 4 (new oneof case)
SiteStreamEventBatch { repeated SiteStreamEvent events = 1 }
The proto3 default of batching_supported IS the negotiation, and it is
load-bearing: a batch frame reaches a pre-R2 central as EventOneofCase.None,
whose ConvertToDomainEvent returns null — the whole batch would vanish with
no error anywhere. An old central cannot set the flag so it never receives
one; an old site ignores the unknown request field and keeps sending
per-event frames, which the new client's ForEachEvent handles as the
single-event case. Both skew directions are covered by tests that go through
a real proto serialize/parse round-trip.
Server: SiteStreamEventBatcher, a per-subscriber pump replacing the handler's
await-foreach/WriteAsync loop and byte-identical to it at a cap of 1. It
never delays a lone event — it drains the already-queued backlog for free and
lingers only once a backlog is proven — emits a single-event buffer as a
plain frame, preserves order and per-event Timestamps exactly, and flushes
what is buffered when the send channel's writer completes. It sits DOWNSTREAM
of StreamRelayActor's bounded DropOldest channel, so it changes framing only
and does not move the burst ceiling (deferred register row 31, which lives in
the shared publish stage upstream of the BroadcastHub).
Client: sets the flag on both subscriptions and unpacks in order into the
existing per-event pipeline, so SiteAlarmAggregatorActor,
DebugStreamBridgeActor, consumer-keepalive/orphan logic,
reconnect-on-graceful-completion, generation fencing, the (siteId, endpoint)
factory key and IsLive semantics are untouched.
Options (validated): GrpcStreamBatchMaxEvents 100 (1 disables),
GrpcStreamBatchWindow 25 ms — validated strictly under 250 ms, the load
test's end-to-end P99 threshold. Measured worst case (trickle-with-backlog,
window-bound rather than cap-bound): P50 13.8 ms, P99 25.4 ms, max 25.8 ms;
cap-bound case sent 600 queued events in 6 frames.
Telemetry: histogram scadabridge.site.stream.batch_size tagged by stream
kind, recorded only on negotiated streams (per-event otherwise). It rides
ScadaBridgeTelemetry.MeterName, already in the ObservedMeters allowlist.
Docs: Component-Communication.md gains an Event Batching section; CLAUDE.md's
gRPC streaming bullet records the wire shape and the negotiation rationale.
Extend CommunicationOptionsValidator with eager bounds for the four T4
live-alarm-cache options (linger >= 0, reconcile > 0, seed concurrency 1..64,
subscribers-per-site >= 1). Enforce the per-site viewer cap fail-safe in
SiteAlarmLiveCacheService.Subscribe (reject excess viewers with a no-op
disposable rather than growing the list or throwing into the Blazor render
path). Surface two telemetry instruments on the existing ScadaBridgeTelemetry
meter: an active-aggregator observable gauge and a reconnect counter, wired from
the aggregator actor's PreStart/PostStop and its NodeA<->NodeB flip /
reconcile-driven reopen.
Claude-Session: https://claude.ai/code/session_01MtdgwpEeCUn6cUA5f1LMPj
Remediation from the full per-module code review at 4307c381 (findings recorded
separately in code-reviews/).
Highs fixed:
- DeploymentManager-025/SiteRuntime-031: stop broadcasting notification lists + SMTP
configs (incl. credentials) to sites; site purges already-persisted rows on apply
(enforces the central-only delivery design; clears plaintext SMTP creds at rest).
- DataConnectionLayer-023: guard the native-alarm subscribe path against the
mid-flight-unsubscribe adapter-feed leak (mirrors the DCL-021 tag-path fix).
- SiteEventLogging-024: normalize From/To query bounds to UTC (the -016 fix the
audit trail claimed but never committed).
- KpiHistory-001: add an in-flight guard to the recorder sample tick.
- ScriptAnalysis-001: harden the trust analyzer's TPA-absent fallback (resolve
forbidden anchors in the minimal reference set; warn on degraded mode) — anchors
added to validation references only, never the compile gate.
(InboundAPI-026 left to the feat/ipsen-movein effort per owner decision.)
Medium/Low: DM-026 deterministic deploy-status tiebreaker; SR-027/028/029/030
native-alarm leak/phantom-active/delete-during-redeploy fixes; AL-013/014/016;
TE-024 (folder-mutation audit rows now persisted)/025; SF-025 gauge-provider
clear-on-stop; ESG-025/026; SEC-023/024/025; SCA-007/008/009; plus doc/test
accuracy COM-023/024, HOST-025/026, HM-024/025, NS-027/028.
Full-solution build 0 warnings; ~3560 tests across 18 touched suites green.