feat(native-alarms): per-binding IsMesReportable on native alarm source bindings (ScadaBridge#59)
TemplateNativeAlarmSource.IsMesReportable + tri-state InstanceNativeAlarmSourceOverride .IsMesReportableOverride flatten onto ResolvedNativeAlarmSource; NativeAlarmActor stamps every mirrored condition and InstanceActor the quiet-binding placeholder, so ScriptAlarm, Alarms.MesReportableAsync() and the #60 wire fields carry it. Additive to the 900-999 severity band. Migration AddNativeAlarmSourceMesReportable. Management commands, CLI --mes-reportable, Central UI (template dialog checkbox, instance override select), Transport DTOs/importer/diff and the revision hash (true-only, so existing hashes are unchanged) carry it. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
@@ -65,7 +65,8 @@ public record SetInstanceNativeAlarmSourceOverrideCommand(
|
||||
string SourceCanonicalName,
|
||||
string? ConnectionNameOverride,
|
||||
string? SourceReferenceOverride,
|
||||
string? ConditionFilterOverride);
|
||||
string? ConditionFilterOverride,
|
||||
bool? IsMesReportableOverride = null); // additive trailing optional; null = inherit the binding's flag
|
||||
|
||||
public record DeleteInstanceNativeAlarmSourceOverrideCommand(
|
||||
int InstanceId,
|
||||
@@ -83,7 +84,8 @@ public record NativeAlarmSourceOverrideEntry(
|
||||
string SourceCanonicalName,
|
||||
string? ConnectionNameOverride,
|
||||
string? SourceReferenceOverride,
|
||||
string? ConditionFilterOverride);
|
||||
string? ConditionFilterOverride,
|
||||
bool? IsMesReportableOverride = null);
|
||||
|
||||
/// <summary>
|
||||
/// Bulk, all-or-nothing apply of per-instance native-alarm-source overrides — the
|
||||
|
||||
@@ -49,8 +49,8 @@ public record AddTemplateAlarmCommand(int TemplateId, string Name, string Trigge
|
||||
public record UpdateTemplateAlarmCommand(int AlarmId, string Name, string TriggerType, int PriorityLevel, string? Description, string? TriggerConfiguration, bool IsLocked, bool IsMesReportable = false);
|
||||
public record DeleteTemplateAlarmCommand(int AlarmId);
|
||||
// Native alarm source bindings (read-only mirror of an OPC UA A&C / MxGateway source's alarms)
|
||||
public record AddTemplateNativeAlarmSourceCommand(int TemplateId, string Name, string ConnectionName, string SourceReference, string? ConditionFilter, string? Description, bool IsLocked);
|
||||
public record UpdateTemplateNativeAlarmSourceCommand(int NativeAlarmSourceId, string Name, string ConnectionName, string SourceReference, string? ConditionFilter, string? Description, bool IsLocked);
|
||||
public record AddTemplateNativeAlarmSourceCommand(int TemplateId, string Name, string ConnectionName, string SourceReference, string? ConditionFilter, string? Description, bool IsLocked, bool IsMesReportable = false);
|
||||
public record UpdateTemplateNativeAlarmSourceCommand(int NativeAlarmSourceId, string Name, string ConnectionName, string SourceReference, string? ConditionFilter, string? Description, bool IsLocked, bool IsMesReportable = false);
|
||||
public record DeleteTemplateNativeAlarmSourceCommand(int NativeAlarmSourceId);
|
||||
public record ListTemplateNativeAlarmSourcesCommand(int TemplateId);
|
||||
// MinTimeBetweenRuns/ExecutionTimeoutSeconds are additive trailing optionals (default null = "unset"):
|
||||
|
||||
@@ -116,8 +116,10 @@ public record AlarmStateChanged(
|
||||
/// <summary>
|
||||
/// True when the alarm's deployed configuration flags it as MES-reportable
|
||||
/// (<c>ResolvedAlarm.IsMesReportable</c>). Stamped by the Instance Actor on its alarm
|
||||
/// snapshot and on every event it relays to the site stream; always false for native
|
||||
/// conditions, which have no per-alarm config row. Carried to central on
|
||||
/// snapshot and on every event it relays to the site stream. For a native condition it is
|
||||
/// the binding-level flag (<c>ResolvedNativeAlarmSource.IsMesReportable</c>, Gitea #59), set by
|
||||
/// the owning <c>NativeAlarmActor</c> — there is still no per-condition config row; the
|
||||
/// 900-999 severity band remains an independent, additive signal. Carried to central on
|
||||
/// <c>AlarmStateUpdate</c> field 25 and <c>DebugAlarmStateDto</c> field 20 (Gitea #60);
|
||||
/// a pre-#60 site sends the proto3 default. Additive; default false.
|
||||
/// </summary>
|
||||
|
||||