Resolve all 46 low-severity architecture review findings
This commit is contained in:
@@ -12,13 +12,10 @@ namespace ZB.MOM.WW.ScadaBridge.Commons.Messages.Streaming;
|
||||
/// <param name="Quality">Quality of the new value (<c>Good</c>/<c>Bad</c>/<c>Uncertain</c>).</param>
|
||||
/// <param name="Timestamp">UTC timestamp of the change.</param>
|
||||
/// <param name="SourceExecutionId">
|
||||
/// Audit Log #23 (ParentExecutionId tag-cascade): the <c>ExecutionId</c> of the
|
||||
/// script execution / inbound API request whose write produced this change, or
|
||||
/// <c>null</c> when the change did not originate from an audited execution —
|
||||
/// which is the case for every value that arrives from the Data Connection
|
||||
/// Layer (external device data), for deployment-time seeding, and for the
|
||||
/// confirmed value of a data-sourced write (the device echo arrives on the
|
||||
/// subscription long after the writing execution ended).
|
||||
/// Execution associated with this change. Static writes carry an observed writer id;
|
||||
/// armed device updates carry only a candidate writer id (see
|
||||
/// <paramref name="SourceExecutionInferred"/>), since subscriptions carry no write-request id.
|
||||
/// Other device updates and deployment seeding carry no id.
|
||||
///
|
||||
/// <para>
|
||||
/// The Alarm Actor records this id as the <c>ParentExecutionId</c> of the
|
||||
@@ -34,6 +31,7 @@ namespace ZB.MOM.WW.ScadaBridge.Commons.Messages.Streaming;
|
||||
/// </para>
|
||||
/// </param>
|
||||
/// <param name="Trace">Flow Debugger trace flag — see design 2026-09-05 §5.2. Additive; defaults to untraced.</param>
|
||||
/// <param name="SourceExecutionInferred">True when the source is inferred from the first device update within the trace-arm window, regardless of value equality, clamping, or coercion; it is not evidence of a write echo.</param>
|
||||
public record AttributeValueChanged(
|
||||
string InstanceUniqueName,
|
||||
string AttributePath,
|
||||
@@ -42,4 +40,5 @@ public record AttributeValueChanged(
|
||||
string Quality,
|
||||
DateTimeOffset Timestamp,
|
||||
Guid? SourceExecutionId = null,
|
||||
bool Trace = false) : ISiteStreamEvent;
|
||||
bool Trace = false,
|
||||
bool SourceExecutionInferred = false) : ISiteStreamEvent;
|
||||
|
||||
Reference in New Issue
Block a user