fix(cluster): leader-auto-down restarts a node its peer has shut out; higher address restarts when both are (#132)
A node frozen past failure detection + StableAfter, or both sides of a partition that heals after each downed the other, used to stay a second active node until an operator restarted one: the peer quarantines the removed UID and Akka.Cluster 1.5.62 never acts on ThisActorSystemQuarantinedEvent. ShutOutRestart (child of the LeaderAutoDown downing actor; opt-out via ScadaBridge:Cluster:LeaderAutoDown:RestartWhenShutOut, default on for leader-auto-down only) watches two signals: - S1 ThisActorSystemQuarantinedEvent: the peer quarantined this node. If the peer is still a live member here, only this side can be shut out -> restart now. - S2 AssociationErrorEvent 'has a UID that has been quarantined': the peer still runs the incarnation this node removed. A healed partition yields only S2, on both sides. Wait ShutOutGrace (60s) for a frozen peer to restart itself, then tiebreak. Tiebreak: the higher address (Akka Member.AddressOrdering) restarts, the lower stays and restarts only if still split one grace later. Removed peers are probed (Identify, 5s -> 60s back-off) since nothing else contacts them after mutual removal. Restart = Cluster.Down(self) -> existing self-down path. The Host now exits 75 after an unplanned ActorSystem termination (and sets it on the Windows service before it reports stopped): SCM recovery with failureflag 1 only restarts a service that stops with a non-zero code, and the watchdog used to exit 0. Shipped default strategy stays auto-down. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
@@ -69,6 +69,8 @@ public sealed class UnexpectedTerminationTests
|
||||
await Task.Delay(500);
|
||||
|
||||
lifetime.Received(1).StopApplication();
|
||||
// ScadaBridge#132: Program turns this flag into the non-zero SelfDownExitCode.
|
||||
Assert.True(service.TerminatedOutsideHostShutdown);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that a normal stop does not trigger an application stop.</summary>
|
||||
@@ -84,5 +86,19 @@ public sealed class UnexpectedTerminationTests
|
||||
await Task.Delay(500);
|
||||
|
||||
lifetime.DidNotReceive().StopApplication();
|
||||
Assert.False(service.TerminatedOutsideHostShutdown);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// ScadaBridge#132: the self-down exit code is non-zero (Windows service recovery with
|
||||
/// failureflag 1 restarts only on a non-zero exit) and is only pushed into a Windows service
|
||||
/// lifetime — a console / docker lifetime is left alone.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void SelfDownExitCode_IsNonZero_AndOnlyAppliedToAServiceLifetime()
|
||||
{
|
||||
Assert.NotEqual(0, AkkaHostedService.SelfDownExitCode);
|
||||
Assert.False(AkkaHostedService.MarkServiceSelfDownExit(null));
|
||||
Assert.False(AkkaHostedService.MarkServiceSelfDownExit(Substitute.For<IHostLifetime>()));
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue