feat(dcl): Layer D OpcUaGlobalOptions for app-wide identity + cert paths

New deployment-wide options bound from the "OpcUa" section of appsettings.json:
- ApplicationName (default "ScadaLink-DCL")
- TrustedIssuerStorePath / TrustedPeerStorePath / RejectedCertificateStorePath

Empty paths fall back to Path.GetTempPath()/ScadaLink/pki/* so dev runs work
without explicit config — same defaults the hardcoded values previously used.

Wiring:
- ServiceCollectionExtensions binds OpcUaGlobalOptions to the OpcUa section.
- DataConnectionFactory takes IOptions<OpcUaGlobalOptions> and constructs
  RealOpcUaClientFactory with the snapshot.
- RealOpcUaClient(globalOptions) replaces the hardcoded ApplicationName and
  the three CertificateTrustList store paths in ApplicationConfiguration.
- Parameterless ctors on factory and client preserved for the existing test
  suite (32/32 DCL tests still green).
This commit is contained in:
Joseph Doherty
2026-05-12 02:27:58 -04:00
parent e6a5b558f3
commit 8faaa8fe2b
4 changed files with 51 additions and 6 deletions
@@ -9,6 +9,9 @@ public static class ServiceCollectionExtensions
services.AddOptions<DataConnectionOptions>()
.BindConfiguration("DataConnectionLayer");
services.AddOptions<OpcUaGlobalOptions>()
.BindConfiguration("OpcUa");
// WP-34: Register the factory for protocol extensibility
services.AddSingleton<IDataConnectionFactory, DataConnectionFactory>();