feat(dcl): Layer D OpcUaGlobalOptions for app-wide identity + cert paths
New deployment-wide options bound from the "OpcUa" section of appsettings.json: - ApplicationName (default "ScadaLink-DCL") - TrustedIssuerStorePath / TrustedPeerStorePath / RejectedCertificateStorePath Empty paths fall back to Path.GetTempPath()/ScadaLink/pki/* so dev runs work without explicit config — same defaults the hardcoded values previously used. Wiring: - ServiceCollectionExtensions binds OpcUaGlobalOptions to the OpcUa section. - DataConnectionFactory takes IOptions<OpcUaGlobalOptions> and constructs RealOpcUaClientFactory with the snapshot. - RealOpcUaClient(globalOptions) replaces the hardcoded ApplicationName and the three CertificateTrustList store paths in ApplicationConfiguration. - Parameterless ctors on factory and client preserved for the existing test suite (32/32 DCL tests still green).
This commit is contained in:
@@ -9,6 +9,9 @@ public static class ServiceCollectionExtensions
|
||||
services.AddOptions<DataConnectionOptions>()
|
||||
.BindConfiguration("DataConnectionLayer");
|
||||
|
||||
services.AddOptions<OpcUaGlobalOptions>()
|
||||
.BindConfiguration("OpcUa");
|
||||
|
||||
// WP-34: Register the factory for protocol extensibility
|
||||
services.AddSingleton<IDataConnectionFactory, DataConnectionFactory>();
|
||||
|
||||
|
||||
Reference in New Issue